Verified by manufacturer 6 months ago
Static-dissipative polyurethane cement self-smoothing floor system.
For use in:
FasTop SL ESD is a static-dissipative resin based flooring system which is installed at 3 mm nominal thickness providing an electrical conductivity leakage resistance of <10^6 ohms when tested to BS EN 61340-4- 1:2004+A1:2015.
The system comprises conductive fillers with selected polyurethane cement resin components and pigments to provide a finish that is resistance against chemical attack and abrasion. It is particularly suited for production areas and clean room type situations where a matt static-dissipative smooth tough and hygienic floor is required.
Features and benefits:
Color | Grey Beige Blue Cream Yellow |
Finish | Matt Smooth |
Material | Polyurethane Resin |
Shape | Formless |
Length | Bespoke |
Width | Bespoke |
Height | 3 mm |
Warranty description | Other |
Uniclass | |
CAWS | M12/110 Resin flooring M12/10 Resin flooring |
Substrate | |
Testing | Moisture content to BS 8204. |
Preparation | Preparation of existing substrates.Guidance for specification option: Substrates must be clean, sound, dry and free of surface laitance with a minimum strength of 25 N/mm². Mechanically prepare substrate to provide a surface texture that will function as a key for the resin. Remove all dust and debris. Repair significant mechanical damage, pitting and cracks. |
Levelling screed | FasTop Multi SL ESD. |
Primer | Not required.Resuseal clear.Guidance for specification option: Optional. Resuprime ESD.Guidance for specification option: ESD primer. |
Movement joints | |
Type | Not required.Epo-Flex™ VJ.Guidance for specification option: The spacing and type of joints should be determined prior to the resin floor system being installed.
|
Abrasion resistance | To BS EN 13892-4:2002, AR 0.5. |
CompressiveStrength | To BS EN ISO 604:2003, 43 MPa. |
TensileStrength | To BS EN ISO 527-2:2012, 7 N/mm². |
Flexural strength | BS EN ISO 178:2010+A1:2013, 26 N/mm². |
Bond strength | To BS EN 13892-8:2002, >3 N/mm². |
Impact resistance | To BS EN 6272-1:2011, >4. |
Temperature resistance | Up to 80°C (at 3 mm). |
Application temperature | 10–25ºC. |
Reaction to fire | To BS EN 13501-1:2018, Bfl–s1. |
System thickness | 3 mm. |
Tape | Copper tape. Manufacturer guidanceearthing tape. |