NBS Source
I'm a manufacturer

em.glaze™ Walk-on Glass - Rooflight

Verified by manufacturer 4 months ago

Whitesales Rooflights

Walk-on glazing for roof terraces and interior flooring, designed to be flush with external flooring.

Jump to:
+44 (0)1483 917580 Website

Application

Suitable for roof terraces and interior flooring.

Description

Walk-on glazing for roof terraces and interior flooring, designed to be flush with external flooring with fully bespoke sizes to suit space and style. Laminated inner glazing as standard, facilitates safety in the unlikely case of breakage. Anti-slip dots may be applied to ensure a safe, non-slip surface to walk on, even in damp conditions.


Features and benefits:

  • Thermally broken frame.
  • Flush glaze glass-to-edge design.
  • Thermal and sound insulation properties.

General information

Color

Grey

Guidance for specification option:

RAL 7016, light grey.

White

Guidance for specification option:

Upstand.

Finish

Powder-coated

Manufacturer guidance

Bespoke requirements for rooflight available.

Material

PVC-U

Guidance for specification option:

Kerb.

Aluminium

Guidance for specification option:

Frame.

Glass

Guidance for specification option:

Unit.

Shape

Square

Rectangle

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

Ten year

Guidance for specification option:

Glazing.

Uniclass

Pr_30_59_72_31 Framed rooflightsPrimary

CAWS

L10/45 Rooflights

L10/460 Rooflights

Product range

em. Range
Glass Rooflights

Specification data - Framed rooflights

Form

Square.

Rectangular.

Size

-

Manufacturer guidance

Bespoke – contact manufacturer.

Product performance

-

Fire performance

-

Fire resistance

BS 476 - External Fire – AA, Non-Combustibility – Class O, Surface Spread Class 1.

Whole window U-value

-

Manufacturer guidance

  • Double glazed total product U-value: Typically 1.6 W/m².K but as low as 1.3 W/m².K.
  • Triple glazed total product U-value: Typically 1.2 W/m².K but as low as 1.0 W/m².K.

Frame

-

Material

Aluminium.

Finish

-

Coating

Powder coating.

Anthracite.

Colour

Light grey, RAL 7016.

Guidance for specification option:

Anthracite finish.

RAL.

Guidance for specification option:

Powder coated to any RAL colour as special order.

Glazing or infill

-

Type

Outer pane: 33 mm heat soak tested toughened and laminated glass + black border - Cavity: 18 mm 90% argon filled; silicone bonded + warm edge spacer - Inner pane(s): 6 mm heat soak tested toughened.

Outer pane: 39 mm heat soak tested toughened and laminated glass + black border - Cavity: 18 mm 90% argon filled; silicone bonded + warm edge spacer - Inner pane(s): 6 mm heat soak tested toughened.

Outer pane: 48 mm heat soak tested toughened and laminated glass + black border - Cavity: 18 mm 90% argon filled; silicone bonded + warm edge spacer - Inner pane(s): 6 mm heat soak tested toughened.

Outer pane: 33 mm heat soak tested toughened and laminated glass + black border - Cavity: 18 mm 90% argon filled; silicone bonded + warm edge spacer - Inner pane(s): 6 mm heat soak tested toughened 13.5 mm heat strengthened laminate.

Outer pane: 39 mm heat soak tested toughened and laminated glass + black border - Cavity: 18 mm 90% argon filled; silicone bonded + warm edge spacer - Inner pane(s): 6 mm heat soak tested toughened 13.5 mm heat strengthened laminate.

Outer pane: 48 mm heat soak tested toughened and laminated glass + black border - Cavity: 18 mm 90% argon filled; silicone bonded + warm edge spacer - Inner pane(s): 6 mm heat soak tested toughened 13.5 mm heat strengthened laminate.

Manufacturer guidance

Soft coat Low-E coating: Always required to meet or exceed Building Regulations Approved Document L target U-values.


Consult manufacturer for details and insert requirements.

Construction

-

Manufacturer guidance

Can be custom designed to any bespoke requirement/ specification required.

Colour

-

Manufacturer guidance

Can be custom designed to any bespoke requirement/ specification required.

Integral kerb

Not required.

PVC-U.

Manufacturer guidance

Walk-on units are bespoke and upstands can be designed to meet desired specification.

Third party certification:

To EN 1991-1-1-1: 2002.

Guidance for specification option:

Standard glass specification is designed to withstand regular foot traffic with uniform loading’s of 1.5 kN/m² and concentrated loading’s of 2.0 kN.

Manufacturer guidance

Full technical details and specification information can be found on the data sheet.

Air permeability

Weather tested to CWCT A4.

Watertightness

R7 Watertightness at peak pressure 600 pa.

Non-fragility rating

CWCT Class 0.

Sustainability data

Contains Red List materials

No

Country of material origin

Europe

Country of product manufacture

Europe

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

30 %

Case studies

The Fry Building, University of Bristol

The Fry Building, University of Bristol