Verified by manufacturer over a year ago
Single glazed
Polycarbonate thermoformed rooflights designed to make optimum use of natural light.
Polycarbonate thermoformed rooflights designed to make optimum use of natural light, available in a wide range of sizes, shapes and glazing options. Normally specified with Whitesales proprietary insulated PVC-U curbs, but can also be installed on existing builders curbs. Higher security, access and ventilation options are available.
Features and benefits:
Color | White Guidance for specification option: Upstand. Grey  | 
Finish | Glazed Guidance for specification option: Double, triple, quad or Eco multiwall glazed dome (quad glazing special order).  | 
Material | PVC-U Guidance for specification option: Upstand. Polycarbonate Guidance for specification option: Rooflight. Aluminium  | 
Shape | Square Guidance for specification option: For pyramid dome profile (section). Rectangle Guidance for specification option: For trapezoidal dome profile (section). Circle Guidance for specification option: For standard dome profile (section). Manufacturer guidanceRooflight shape (plan).  | 
Length | 400 mm 500 mm 550 mm 600 mm 700 mm  | 
Width | 400 mm 500 mm 550 mm 600 mm 700 mm  | 
Height | Bespoke  | 
Warranty description | Ten year Guidance for specification option: Glazing. One year Guidance for specification option: Mechanical components.  | 
Uniclass | |
CAWS | L10/45 Rooflights L10/460 Rooflights L10/490 Roof ventilators  | 
Product range | 
Classification data | |
Form | Dome. Guidance for specification option: Standard. Pyramid. Guidance for specification option: Section for square rooflights. Trapezoid. Guidance for specification option: Section for rectangular rooflights. Square. Rectangular. Round.  | 
Size | Guidance for specification option: 300 x 300 to 1800 x 3000 mm. Over 40 sizes available for domes, specify from product literature (size chart), or consult manufacturer.  | 
Product performance | |
Fire performance | |
Fire resistance | To BS 476:Part3 AA, Class 1. To 1991 Building Regulations. Guidance for specification option: Tp(a).  | 
Frame | |
Material | uPVC. Guidance for specification option: 
  | 
Finish | |
Colour | White, self finished.  | 
Glazing or infill | |
Type | Polycarbonate sheet. Guidance for specification option: At least 3 mm thick. 'Non-fragile' certified.  | 
Construction | Single skin. Guidance for specification option: Suited to non-heated, external areas such as canopies and out-buildings. Manufacturer guidanceConsult product literature for technical characteristics of glazing options.  | 
Colour | Clear. Opal diffused. Guidance for specification option: 
 Heat-reflect. Guidance for specification option: Reflects up to 68% solar energy, minimizing heat build-up in rooms below. Bronze tint.  | 
Coating | UV protected.  | 
Integral kerb | Not required. Guidance for specification option: 
 PVC-U, 150 mm high, vertical, white. Guidance for specification option: 
 PVC-U, 150 mm high, splayed, white. Guidance for specification option: 
 PVC-U, 300 mm high, splayed, white. Guidance for specification option: 
 PVC-U, 350 mm high, oversleeve, white. Guidance for specification option: Oversleeves existing upstand to avoid disturbing internal lining, asbestos etc. PVC-U adaptor collar. Guidance for specification option: 
  | 
Accessories | Not required. Burglar bar grid. Security frame. Vent Control Pack. Guidance for specification option: 
  | 
Ventilation/ opening | Not required. Guidance for specification option: 
 Access hatch. Guidance for specification option: Hinged and lockable access hatch to allow safe access to roof or plant areas. Controllable rotating, two sides. Guidance for specification option: 
 Controllable rotating, four sides. Guidance for specification option: 
 Controllable trickle, two sides. Guidance for specification option: Provides minimum 8 000 mm² vent to assist compliance with Building Regulations. Controllable trickle, four sides. Guidance for specification option: Provides minimum 16 000 mm² vent to assist compliance with Building Regulations. Electric hinged opener. Guidance for specification option: 
 Extract fan. Guidance for specification option: 
 Manual hinged opener. Guidance for specification option: 
 Permanent. Guidance for specification option: Permanent, non-controllable spacer washers for corridors and non-inhabited rooms. Smoke vent. Guidance for specification option: 
 Manufacturer guidanceVentilation options include controllable rotary trickle vents and electric opening.  | 
Third party certification: | CE Certifiied to EN 1873.  | 
Ventilation | Em.domes to suit builders upstand. Guidance for specification option: 
 Em.domes with proprietary upstand. Guidance for specification option: Available as fixed unit with or without rotating trickle vents. Manually or electrically opening, with or without rotating trickle vents. Manufacturer guidanceVentilation options, refer to product directory for more information. 
  | 
Contains Red List materials | Yes  | 
Country of material origin | Europe  | 
Country of product manufacture | Europe  | 
Recyclability | The polycarbonate lids can be sorted for recycling can be re-used. As a thermoplastic, polycarbonate in its pure form is suitable for mechanical recycling.  | 
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
| Platform | Compatible | Version | 
|---|---|---|
Revit 2016  | 1  |