Verified by manufacturer over a year ago
Solvent-free MMA car park deck coating system.
Suitable for use over exposed decks of multi-storey car parks and the refurbishment of existing car parks and on new construction projects.
IMPORTANT: All specification information must be checked against the individual site requirements. Flowcrete advises that specifications are confirmed with their technical experts.
A solvent-free methyl methacrylate car park deck coating system which provides a crack bridging, waterproof wearing surface and enables fast track applications whilst also offering slip resistance properties.
Features and benefits:
Color | Blue Green Grey Purple Red |
Finish | Satin Matt |
Material | Methyl methacrylate Guidance for specification option: Methyl methacrylate coating. |
Warranty description | Ten year |
Uniclass | |
CAWS | M12/10 Resin flooring M12/110 Resin flooring |
Substrate | |
Preparation | Concrete or screed substrate should be a minimum of 25 N/mm², free from laitance, dust and other contamination and should be dry to 95% RH as per BS 8204. |
Resin flooring | Methyl methacrylate coating. |
Adhesion | >1.5 N/mm². |
Certification | CE Marked. |
Chemical resistance | Protects against diesel, antifreeze, hydraulic fluids, chlorides and battery acids. |
Chloride ion resistance | No penetration after 28 days. |
Colour options | Dark Grey. Forest Green. Mid Grey. Tile Red. Traffic Blue. |
Crack bridging | To UNE-EN 1062-7:2004: Class A3 at -10°C; no cracks at -20°C. |
Cure time | Full traffic and chemical cure within three hours. |
Impact resistance | Class II: ≥10 Nm. |
Retroflectivity | Not required. Required. Guidance for specification option: By request; consult manufacturer for details and insert requirements. |
Slip resistance | To UNE-EN 13036-4:2003, Class III (>55 units wet). Guidance for specification option: (outside). |
Temperature resistance | Softens over 70°C and hardens on cooling. |
Thickness range | 4–5 mm. |
Water permeability | To UNE-EN 1062-3:2008, < 0.1 kg/m²/h. |
Weathering resistance | To UNE-EN 1062-11:2003 4.2 (2000 h), no defects. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 3 | |
- | 2 |