Verified by manufacturer 2 months ago
A fully adhered, single ply membrane warm roof system.
UltraPly™ TPO Fully Adhered System is a lightweight system with design flexibility. Membrane panels are fully adhered directly to an acceptable substrate using Elevate Bonding Adhesive.
Features and benefits:
System components:
Color | White Grey |
Material | Polyolefin Polyisocyanurate (PIR) |
Uniclass | |
CAWS | J42/10 Warm deck roof covering J42/110 Warm deck roof covering |
Preparation | - |
Horizontal work | SA-19 Primer.Elevate SA-19 Primer is used to prime and prepare exterior concrete, wood, and metal surfaces to enhance the adhesion of Elevate V-Gard vapour control membrane. It's also used to prime seams when required. |
Skirtings and vertical work | SA-19 Primer.Elevate SA-19 Primer is used to prime and prepare exterior concrete, wood, and metal surfaces to enhance the adhesion of Elevate V-Gard vapour control membrane. It's also used to prime seams when required. |
Air and vapour control layer | - |
Type | V-Gard Vapor Control layer.Elevate V-Gard Vapor Control Membrane is designed to be used as a vapour control layer in Elevate roofing systems. It consists of a reinforced aluminium foil with self-adhesive bituminous backing protected by a release film. The fibreglass reinforcement makes it suitable for applications that involve high mechanical stresses. The Elevate V-Gard membrane can be installed on concrete, wood and steel deck. |
Attachment | Self-adhesive bituminous backing. |
Insulation | - |
TypeConsult the manufacturer's Technical Services Department for R-Value/U-value calculations as required. | ISOGARD AK PIR Insulation.Thermal conductivity: 0.023 W/m.K. Thickness: 30–160 mm. Insert requirements. Elevate ISOGARD AK insulation board consists of a closed-cell polyiso (PIR) foam core laminated on both sides to a gastight multi-layered aluminium complex. ISOGARD MG PIR Insulation.Thermal conductivity: 0.025–0.028 W/m.K. Thickness: 30–160 mm. Insert requirements. Elevate ISOGARD MG insulation board consists of a closed-cell polyiso (PIR) foam core laminated on both sides to a gasopen mineral glassfibre facer. RESISTA AK PIR Insulation.Thermal conductivity: 0.023 W/m.K. Thickness: 30–160 mm. Insert requirements. Elevate RESISTA AK insulation board consists of a closed-cell polyiso (PIR) foam core laminated on both sides to a gastight multi-layered aluminium complex. RESISTA MG PIR Insulation.Thermal conductivity: 0.025–0.028 W/m.K. Thickness: 30–160 mm. Insert requirements. Elevate RESISTA MG insulation board consists of a closed-cell polyiso (PIR) foam core laminated on both sides to a gasopen mineral glassfibre facer. ISOGARD HD.As per RubberGard EPDM Fully Adhered Warm Roof spec. |
Attachment | I.S.O. Twin Pack Insulation Adhesive.Elevate I.S.O. Twin Pack Insulation Adhesive is a two-component low-rise polyurethane adhesive designed for anchoring acceptable roof insulation and cover boards to an acceptable substrate, as well as for adhering multiple layers of insulation. It is a solvent-free insulation adhesive that contains no harmful HCFC or CFC. |
Waterproof covering | - |
TypeA flexible thermoplastic polyolefin membrane, incorporating ethylene-propylene rubber into a polypropylene matrix, with a polyester weft-inserted scrim reinforcement, manufactured in an ISO 9001 and ISO 14001 registered facility. Specification compliance: UL Classified/ FM Approved. ASTM D 6878-2013/ EN 13956 (CE Mark). 7500 hrs of Artificial Ageing as per EN 1297. | UltraPly™ TPO Roofing Membrane 1.1 mm.UltraPly™ TPO Roofing Membrane 1.2 mm.UltraPly™ TPO Roofing Membrane 1.5 mm.UltraPly™ TPO Roofing Membrane 1.8 mm. |
AttachmentSuper spreader or roller applied contact adhesives. Contact the manufacturer's Technical Department for details on defining the proper method of attachment for the substrate. | BA-2012 Bonding Adhesive.UltraPly Bonding Adhesive. |
Joints | 75 mm minimum overlap with welded seam. |
Surface protection | UltraPly TPO walkway pads.Elevate UltraPly TPO Walkway Pad is a 762 mm wide walkway made of flexible thermoplastic polyolefin and produced with a polyester weft inserted reinforcement. It has a white, textured, slip-resistant top surface. It is required to protect the roofing system from damage in areas with intensive rooftop traffic (hatches, doorways, ladders and roofs subject to periodic traffic for maintenance of technical equipment). |
System accessories | UltraPly TPO Coated Metal Plate.UltraPly TPO Cut Edge Sealant.UltraPly TPO QuickSeam Flashing.UltraPly TPO Joint Cover.UltraPly TPO Inside/Outside Corners.UltraPly TPO Walkway Pad.UltraPly TPO General Purpose Sealant.Water Block Seal (S-20).Pourable Sealer S-10 (Parts A & B).Splice Wash SW-100.Bonding Adhesive BA-2012.Coiled Metal Batten Strip.HD Seam Plates.Single Ply QuickPrime Primer.All Purpose (AP) Fasteners.Heavy Duty (HD) Fasteners.Termination Bar. |
Corners | Corners formed using UltraPly TPO Pre-moulded inside/outside corner. Corners field-fabricated using UltraPly TPO Unsupported Flashing. |
Pipes | Pipe penetrations: Flash with pre-moulded UltraPly TPO Pipe Flashing, Field flashing using UltraPly TPO Unsupported Flashing or UltraPly TPO Penetration Pocket Kit |
Outlets | Drains: Install Water Block Sealant between membrane and outlet bowl. Secure membrane mechanically to outlet using integral clamping ring. Drains: Insert outlet bedded on Water Block Sealant. Secure and flash with QuickSeam Flashing. |
Walls | Wall terminations: Termination bar, fastened with Water Block Sealant and GP Sealant installed along top edge. @200mm (maximum) o.c. Wall terminations: Metal batten bar fastened with surface mounted or inserted metal counter flashing protection. @150mm (maximum) o.c. Wall terminations: Metal capping or concrete coping stones. Wall termination: Edge trim formed from UltraPly TPO Coated Metal. An edge trim will be prefabricated using UltraPly TPO Coated Metal and installed with fasteners @ maximum 200 mm centres. The UltraPly TPO roofing membrane will be sealed to the trim by hot-air welding. Wall termination: Preformed metal edge trim. |
Colour/ Finish | White. Grey. |
Platform | Compatible | Version |
---|---|---|
![]() | - | 1 |
RubberGard™ EPDM Ballasted Warm Roof System
RubberGard™ EPDM Fully Adhered Warm Roof System
RubberGard™ EPDM Inverted Warm Roof System
RubberGard™ EPDM Mechanically Attached Warm Roof System
UltraPly™ TPO Inverted Warm Roof System
UltraPly™ TPO Ballasted Warm Roof System
UltraPly™ TPO Mechanically Attached Warm Roof System