For use on walls and ceilings.

Description

Safewood Insulating Basecoat is the intumescent layer for the Safewood Anti-Viral SFR System that gives both anti-viral and fire protection on bare and painted wood.


Features and benefits:

  • Available in pack sizes of 20 m², 40 m² and 80 m².
  • Compliant with BS EN 13501, B-s1,d0 standards, for full control of flamespread and toxic smoke emission on painted internal walls and ceilings.
  • Can be used as part of a system to achieve 30 or 60 minute fire resistance.
  • Part one of system to make walls anti-viral and anti-bacterial- both with +90% efficacy. 


Application:

  • All surfaces must be clean and dry. Remove all possible surface contaminates such as grease, smoke residues and silicates.
  • Brush or roller applied via woven fabric roller sleeves and synthetic bristle brushes or spray applied using a pressure pot and gun conventional unit with small compressor.
  • Abrade hard or smooth surfaces with wetted 120 grit wet or dry abrasive or dust extracting abrader. Rinse off slurry while still damp. When dry remove any loose or suspect material back to firm edge. 
  • Fill and repair any damage to the substrate using a remedial filler.
  •  Apply one coat of Thermoguard Safewalls Insulating Basecoat to be overcoated with Safewalls Anti-Viral Smoke and Flame Retardant. Apply at rate stated on can to protect surfaces and enable project certification.

General information

Color

White

Material

Water-based

Shape

Formless

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Pr_35_31_68_29 Flame-retardant coatingsPrimary
Pr_35_31_68_40 Hygienic coatings

CAWS

M60/172 Flame-retardant coating system

M60/18 Special coating

M60/195 Special coating

M60/175 Protective coating

M60/19 Flame-retardant coatings

Specification data - Flame-retardant coatings

Reaction to fire rating (indicative)

To BS EN 13501, B-s1,d0.

Solvent

Water-based.

VOC content (maximum)

16 g/L.

Colour

White.

Application temperature

8–30°C.

Guidance for specification option:

  • Maximum relative Humidity below 75%.
  • Surface should be at least 3°C above the dew point. 

Composition

Catalytic powder.

Guidance for specification option:

Expansion agent, insulating char former, char hardeners and fibres Binder: fire protection adhesive grade rapid reaction acrylic resin. Water based.

Drying time

Touch dry in one hour; paintable with Safewalls Anti-Viral SFR after four hours.

Density

1.32 g/ml.

Similar products from Thermoguard UK Ltd

Protection Paints Vira-Protect

Protection Paints Vira-Protect

Thermoguard Asbestos Encapsulating Smoke & Flame Retardant

Thermoguard Asbestos Encapsulating Smoke & Flame Retardant

Thermoguard Fire Varnish Basecoat

Thermoguard Fire Varnish Basecoat

Thermoguard Fire Varnish Overcoat Exterior

Thermoguard Fire Varnish Overcoat Exterior

Thermoguard Flame Retardant Topcoat

Thermoguard Flame Retardant Topcoat

Thermoguard Safeceilings Onecoat Ultramatt

Thermoguard Safeceilings Onecoat Ultramatt

Thermoguard Safewalls Onecoat Anti-Viral Smoke & Flame Retardant

Thermoguard Safewalls Onecoat Anti-Viral Smoke & Flame Retardant

Thermoguard Smoke & Flame Retardant SFR Dualcoat

Thermoguard Smoke & Flame Retardant SFR Dualcoat

Thermoguard Timbercoat Intumescent Basecoat

Thermoguard Timbercoat Intumescent Basecoat

Thermoguard Wallcoat Insulating Basecoat

Thermoguard Wallcoat Insulating Basecoat