Verified by manufacturer over a year ago
Rockpanel Lines - 8 mm
Prefabricated compressed mineral wool cladding boards with thermo-setting synthetic binders.
External façade installations.
Prefabricated compressed mineral wool cladding boards with thermo-setting synthetic binders offer the longevity of stone and the added flexibility of being as easy to work with as wood, in one product. These distinctive properties result in highly durable, workable, and low maintenance cladding boards and are a direct alternative to fibre cement cladding panels.
In addition to the vast range of standard colours available (almost all RAL and NCS colours), these mineral fibre boards are also available in a range of special finishes such as Rockpanel Woods, Stone, Metallic and Chameleon - where the colour of the boards change depending on the viewers vantage point and the amount of natural light available. These flexible and robust boards can be applied easily and can even be shaped, curved and perforated.
The European Reaction to Fire classification system (Euro classes) of all Rockpanel products is based on testing with non-combustible mineral wool insulation. For high-rise buildings and high-risk buildings, Rockpanel recommends the application of non-combustible (Euroclass A1-A2) cladding and insulation.
Features and benefits:
Color | Other |
Finish | Other |
Material | Mineral wool Timber Steel Aluminium |
Shape | Other |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | H20/150 Sheet cladding (attached to metal support systems) H20/10 Sheet cladding H92/120 Rainscreen cladding |
Thermal insulation | Mineral wool slab insulation.Guidance for specification option: Consult manufacturer and insert requirements or omit. |
Breather membrane | |
Material | Guidance for specification option: Consult manufacturer and insert requirements or omit. |
Fasteners | Guidance for specification option: Consult manufacturer and insert requirements or omit. |
Secondary support structure | Aluminium carrier rails.Stainless steel carrier rails.Timber carrier rails. |
Cavity fire barriers | |
Horizontal | Guidance for specification option: Consult manufacturer and insert requirements or omit. |
Vertical | Guidance for specification option: Consult manufacturer and insert requirements or omit. |
Cladding panels | |
Material | Compressed rock fibre panels. |
Panel joints | Guidance for specification option: Consult manufacturer and insert requirements or omit. |
Reveals | Guidance for specification option: Consult manufacturer and insert requirements or omit. |
System accessories | Guidance for specification option: Consult manufacturer and insert requirements or omit. |
Panel Type | Rockpanel Lines. |
Panel size | 164 x 3050 mm. Guidance for specification option: Working width: 151—156 mm. 295 x 3050 mm. Guidance for specification option: Working width: 282—287 mm. Manufacturer guidanceStandard dimensions. |
Thickness | 8 mm. |
Fixing | Screws. Guidance for specification option: Visible fixing. Panels can be attached with screws (wooden or metal) to the support structure. Rivets. Guidance for specification option: Visible fixing. Panels can be attached to the metal support structure using rivets. Nails. Guidance for specification option: Semi-visible. Mechanical fastening. Guidance for specification option: Invisible. Panels can be installed using an invisible mechanical fastening system, where the backs of the panels are fitted with fastening points, in which panel hooks are placed with a tension-free anchor. |
Colour | Guidance for specification option: Consult manufacturer for options and insert requirements. |
Density | To EN 323, 1050 kg/m³. Manufacturer guidanceAverage Density - Oven Dry (kg·m‾³). |
Composition | Durable. |
Colour stability | To ISO 105 A02, 3—4. Guidance for specification option: Or better. Manufacturer guidance5000 h. |
Fire classification | To EN 13501-1, B-s2,d0. |
Weight | 8.4 kg/m². |
Coefficient of thermal expansion | To EN 438:2, 10.5 x 10‾³ mm/m∙K. Guidance for specification option: Clause 17. |
Coefficient of moisture expansion | To EN 438:2, 0.302 mm/n. Guidance for specification option: Clause 17. |
BendingStrength | To EN 310 and EN 1058, 27 N/mm². |
Modulus of elasticity | To EN 310, 4015 N/mm². |
ThermalConductivity | To EN 10456, 0.37 W/m∙K. |
Water vapour permeability | Guidance for specification option: Not applicable, non ventilated. Manufacturer guidanceSd (at 23 °C and 85 % RF) Colours. |
Recyclability | Almost 100% recyclable |