NBS Source
I'm a manufacturer
Compare variants

Anvil Metal Cladding - Interlocking Multi Plane

Verified by manufacturer 1 year ago

Polyester powder-coated aluminium

Taylor Maxwell Variant:

Metal cladding using an interlocking multi plane (IMP) system with a secret fix joint.

Jump to:
0203 794 9377 Website

Application

External façade installations.

Description

Anvil is a range of aluminium rainscreen cladding panels that are attached using framing systems to the outer skin of the building construction. Anvil metal cladding panels can be manufactured to size and fabricated using aluminium, stainless steel, copper, Corten steel and zinc metals, which can be supplied in either an anodized, painted or mill finish.


Anvil metal cladding is available using an interlocking multi plane (IMP) system with a secret fix joint.


Features and benefits:

  • The secret fix joint means there are no visible fixings, providing a precise and uniform finish to the façade.
  • To suit individual design requirements, the IMP panel system can be utilized to create a range of façade patterns.
  • The system can employ a mix of wedge-shaped and variable depth cassettes, allowing the creation of varying panel configurations and geometric effects.
  • These cassettes can then be laid in a multi-directional fashion, allowing the construction of highly creative aesthetic details.
  • It is possible to perforate the faces of the cassettes, providing another means of generating unique and decorative visual effects on the façade with perforated aluminium panels.
  • The IMP system is available with a PPC, natural metal, or anodized finish. 


For samples, further details regarding the colours/ finishes available or technical details, please contact Taylor Maxwell.

General information

Color

Silver

Black

Blue

Brown

Copper

Show more

Finish

Powder-coated

Anodized

Natural

Coated

Material

Aluminium

Copper

Cor-Ten

Stainless steel

Zinc

Show more

Shape

Other

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H20/150 Sheet cladding (attached to metal support systems)

H20/10 Sheet cladding

H92/120 Rainscreen cladding

Specification data - Drained and back-ventilated rainscreen cladding systems

Thermal insulation

Guidance for specification option:

Consult manufacturer and insert requirements or omit.

Breather membrane

-

Material

Guidance for specification option:

Consult manufacturer and insert requirements or omit.

Fasteners

Guidance for specification option:

Consult manufacturer and insert requirements or omit.

Secondary support structure

FloorSpan framing system.

Guidance for specification option:

FloorSpan is a aluminium rainscreen framing system.

  • FloorSpan is extruded from 6063 T6 aluminium.
  • CWCT tested to withstand 2.4 kn/m² of wind pressure with the vertical framing fixed at 1200 mm wide spacings.
  • Sheeting rails can be extruded in lengths to suit individual projects.
  • Primary angles are manufactured in various sizes to suit project specific requirements.
  • Manufactured from aluminium alloys to EN 573-3 and EN 515 production standards.

Artus helping hand bracket cladding fixing systems.

Guidance for specification option:

Artus is a range of helping hand bracket cladding fixing systems used to support the rainscreen cladding system on a façade.

  • Available in Aluminium or stainless steel.
  • Compatible with several façade systems, a helping hand bracket system is an adjustable framing support made up of T & L rails and brackets.
  • Increased insulation thickness - greater standoffs.
  • Increased speed of installation.
  • Adjustability - building tolerances.
  • Lightweight.
  • Engineered, calculated and designed solution.

Cavity fire barriers

-

Horizontal

Guidance for specification option:

Consult manufacturer and insert requirements or omit.

Vertical

Guidance for specification option:

Consult manufacturer and insert requirements or omit.

Cladding panels

-

Material

Aluminium.

Panel joints

Interlocking multi plane (IMP) system with a secret fix joint.

Reveals

Guidance for specification option:

Consult manufacturer and insert requirements or omit.

System accessories

Guidance for specification option:

Consult manufacturer and insert requirements or omit.

Joint width

10 mm.

Manufacturer guidance

Minimum joint width.

Surface finish

Polyester powder-coated.

Guidance for specification option:

Insert colour requirements below.

Colour

-

Manufacturer guidance

Consult manufacturer for options and insert requirements.