Verified by manufacturer 4 months ago
Dual function top hung and centre pivot roof window.
Top hung and pivot roof window suitable for roofs of 15–55º pitch. (55-75° available please contact Fakro).
Dual function top hung and centre pivot roof window.
Features and benefits:
Color | Clear Beige Brown White Other |
Finish | Acrylic Powder-coated Painted |
Material | Glass Wood Pine Timber |
Shape | Rectangle Square |
Warranty description | Ten year Guidance for specification option: For windows. 20 year Guidance for specification option: For glazing. |
Uniclass | |
CAWS | L10/46 Roof windows L10/480 Roof windows |
Standard | Non-fire- and/ or smoke-rated windows to BS EN 14351-1. |
Product performance | |
Whole window U-value | Guidance for specification option:
Manufacturer guidance(using the standard insulated P2 anti-burglary glass): |
Frame | |
Finish as delivered | Water based acrylic lacquer, clear matt.Guidance for specification option: FPP-V preSelect. Water based acrylic, white.Guidance for specification option: FPW-V preSelect. Polyurethane varnish, white.Guidance for specification option: FPU-V preSelect. Water based acrylic lacquer, afromosia.Guidance for specification option: FP preSelect. Water based acrylic lacquer, light oak.Guidance for specification option: FP preSelect. Water based acrylic lacquer, mahogany.Guidance for specification option: FP preSelect. Water based acrylic lacquer, teak.Guidance for specification option: FP preSelect. Water based acrylic lacquer, walnut.Guidance for specification option: FP preSelect. Painted, RAL.Guidance for specification option: Insert RAL colour reference, FPP-V preSelect. Manufacturer guidanceInternal frames and sashes: |
Ventilator | V40P semi-automatic air vent.Guidance for specification option: V40P air inlet gives air flow of 20–49m³ and allows ventilation without operating the sash. Manufacturer guidanceNon-vented windows are available in all types. |
Glazing or infill | |
Composition | Insulated, laminated glass inner - P2.Guidance for specification option:
Insulated, noise-resistant glass inner - R1.Guidance for specification option:
Insulated, obscured glass outer - O2.Guidance for specification option: 4 mm toughened glass outer with embossed pattern, 14mm argon filled cavity, 6.6 mm laminated inner pane with low e coating facing into the cavity. Insulated, reflective glass outer - H.Guidance for specification option:
Insert tint. Insulated, security glazing - P4.Guidance for specification option: 4 mm toughened glass outer, 15 mm argon filled cavity,6.8 mm laminated inner pane with a 1.52 mm layer of PVB (Polyvinyl butyral) between and with low e coating facing into cavity. Insulated, triple glazed - P5.Guidance for specification option:
Insert tint. Insulated, tinted glass outer - W.Guidance for specification option: 4 mm toughened outer pane, 10 mm argon filled cavity, 4 mm toughened middle pane, 8 mm argon filled cavity, 6.6 mm laminated inner pane with low e coating facing the cavity. |
Hardware | Guidance for specification option: All windows come with a handle at the bottom, top-safe anti-burglary system, semi automatic air inlet, quadruple sealing system and a sash guiding system. |
Operation | |
Type | Electronic with remote control (Z Wave).Electronic with wall switch (Z Wave).Manual.Rain sensor.Guidance for specification option: Requires electronic operation. Smoke ventilation system.Wind sensor.Guidance for specification option: Requires electronic operation. Manufacturer guidanceUnique operation of top hung or centre pivot mode using the preSelect switch found in the side of the frame. |
Accessories | Not required.Control rod, ZST.Guidance for specification option: Manual operation of internal blinds. Control rod, ZSZ.Guidance for specification option: Manual operation of external awning blinds. Insect screen, AMS.Guidance for specification option: Glass fibre netting screen on aluminium runners. Window lock, ZBL.Manufacturer guidance(Note: use of outside furniture can restrict window size: consult Fakro for details.) |
Window code | FPP. Guidance for specification option: Non vented. Available in all finishes - to order. FPP-V preSelect. Guidance for specification option: Natural pine clear matt lacquer internal finish. FPW-V preSelect. Guidance for specification option: Natural pine white acrylic internal finish. FPU-V preSelect. Guidance for specification option: Natural pine white polyurethane lacquer internal finish. FPP-V/C preSelect. Guidance for specification option: Natural pine clear matt lacquer internal finish. Conservation style with imitation sash bar and black external cladding. |
Window size code | 02. Guidance for specification option: 550 x 980 mm. 03. Guidance for specification option: 660 x 980 mm. 04. Guidance for specification option: 660 x 1180 mm. 05. Guidance for specification option: 780 x 980 mm. 06. Guidance for specification option: 780 x 1180 mm. |
External cladding finish | Aluminium, polyester powder coated RAL 7022. Guidance for specification option: Brown as standard. Aluminium, polyester powder coated RAL. Guidance for specification option: Insert RAL colour reference. Copper. Titanium zinc. |
Flashing | EEJ. Guidance for specification option: Sheet metal/zinc type roofing for recessed application. Please state metal/zinc and the manufacturer being used. EEV. Guidance for specification option: Sheet metal/zinc type roofing. Please state metal/zinc and the manufacturer being used. EFW. Guidance for specification option: Flat roof kerb and upstand with claddings. EHA. Guidance for specification option: Profiled roof coverings up to 90 mm deep. To suit roof pitch 10-75° raises rear of window 10°. EHN. Guidance for specification option: Profiled roof coverings up to 90 mm deep. Manufacturer guidanceFlashing: Flashings are coded for applications as follows: – First letter: E: Denotes single window flashing. – Second letter: Denotes the compatible roof covering.
– Third letter: Denotes the position of the roof window in relation to the roof.
Specialized flashings are available for horizontal and vertical window groups, mansard junctions and windows installed on either side of the ridge. Consult Fakro for guidance and availability. |
Material and finish | Aluminium with polyester powder coating, RAL 7022. Guidance for specification option: Brown as standard. Aluminium with polyester powder coating, RAL. Guidance for specification option: Insert RAL colour reference. |
Blind | Not required AJP. Guidance for specification option: Venetian blind. Insert colour. AJP-B. Guidance for specification option: Venetian blind with remote adjustment of angle of slats. Insert colour. AJP-E. Guidance for specification option: Venetian blind with electronic operation. Insert colour. AMZ. Guidance for specification option: External awning blind with manual operation. Insert colour. Manufacturer guidanceConsult Fakro for availability of fabrics and to obtain samples. External roller shutters are supplied in dark or light grey. |
Other requirements | Not required. Air-permeable underfelt collar, XDP. Airtight flashing, XDS. Duet slat, XSP. Guidance for specification option: Lacquered pine finish. Duet slat, XSW. Guidance for specification option: White finish. |
Contains Red List materials | No |
Country of material origin | Poland |
Country of product manufacture | Poland |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 61.3 kg CO₂ eq/kg Self declared |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 67 % |
Centre Pivot Smoke Ventilation AOV Roof Window (FSR P2) - Smoke Vent Window
FPT MAX U6 Top Hung And Pivot Window
FW Side Hung Escape Window
Galeria Balcony Roof Window (FGH V P2)
L-shaped Combination Window
Natural Pine Centre Pivot Roof Window (FTP-V)
Natural Pine Passive Certified Quadruple Glazed Centre Pivot Roof Window (FTT U8)
Natural Pine Triple Glazed Centre Pivot Roof Window (FTT U6)
WG Access Rooflight
WLI Access Rooflight