Verified by manufacturer 1 day ago
DN 70
A thermally-insulated rainwater outlet with vertical spigot.
For use with Bauder bituminous waterproofing membranes when connecting to conventional gravity drainage systems.
Designed to be used in warm, cold, and inverted roof scenarios.
Spigot designed to fit standard 75 mm (DN 70) and 160 mm (DN 150) pipework.
A thermally-insulated, cast polyurethane rainwater outlet with vertical spigot giving thermal continuity. The outlet comes with a pre-attached bituminous flange to ensure waterproofing integrity between the outlet and membranes.
The BRE Certified (report no. HPR357-303748) high thermal value of the rigid foam body prevents condensation from forming on the underside of the outlet body. Outlet has a flow rate of 7.1 (70DN) and 7.2 (150DN) L/s based upon requirements of BS EN 12056:3:2000.
Where a warm roof system is specified, a separate extension piece will need to be ordered to maintain thermal integrity. This is available with a spigot length that can range from 60 to 220 mm according to the insulation thickness specified.
A separate 60-mm thick extension unit housing can also be ordered to accommodate the extension piece to save having to cut insulation on site to suit.
Also available as a DN 100 outlet (specified separately).
Color | Black Yellow Cream |
Finish | Smooth |
Material | Polyurethane Guidance for specification option: A one-piece rigid polyurethane foam body. Bitumen Guidance for specification option: SBS elastomeric bitumen connecting membrane. |
Shape | Square Circle |
Length | 495 mm Guidance for specification option: Flange width. |
Width | 495 mm Guidance for specification option: Flange width. |
Height | 258 mm Guidance for specification option: Outlet including spigot. |
Warranty description | Manufacturer guidanceA comprehensive range of guarantee options are available. Please contact your local Bauder Area Technical Manager for more information. |
Uniclass | |
CAWS | R10/26 Proprietary rainwater outlets R10/365 Proprietary rainwater outlets |
Roof construction | |
Form | Guidance for specification option: Insert details. |
Roof insulation thickness | Guidance for specification option: Insert details. |
Material | Cast polyurethane body; bituminous flange with a polyethylene film.Guidance for specification option:
|
Grating | Leaf grille. |
Spigots | Designed to fit standard 75 mm pipework (DN 70). |
Integral accessories | Extension unit (warm roofs only).Guidance for specification option:
Extension unit housing (warm roofs only).Guidance for specification option:
None. |
Flow rate | 7.1 L/s. Manufacturer guidanceFlow rate performance data using a 35 mm head of water (including leaf grille), based upon requirements of BS EN 12056:3:2000. Further flow rate performance data can be obtained within this document. For bespoke drainage calculation performance data, contact manufacturer. |
Weight | 2.5 kg. Guidance for specification option: Outlet only; see Integral accessories guidance for other components. |
Other accessories | None. Reinforcement plate (for metal decks only). |
Country of product manufacture | Germany |
Material | Polyurethane Guidance for specification option: A one-piece rigid polyurethane foam body. Bitumen Guidance for specification option: SBS elastomeric bitumen connecting membrane. |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | Manufacturer guidancePlease refer to EPD on the Bauder website. |