NBS Source
I'm a manufacturer

RubberGard™ EPDM Ballasted Warm Roof System

Verified by manufacturer 4 months ago

Elevate EMEA Third party certifications:
  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

  • EPD

    EPD

    Certificate type

A ballasted EPDM warm roof system.

Jump to:
+44 (0)1565 756186 Website

Application

Can be applied on any building that can accommodate the extra load of the ballast and where the roof slope does not exceed 10%.

Description

The RubberGard™ EPDM Ballasted System is an economical EPDM roofing system, suitable for a wide variety of buildings. The membrane is loosely laid over the substrate and held in place using approved ballast.


Features and benefits:

  • Circular system.
  • Low installation cost.
  • Use of large EPDM sheets.
  • Fewer seams.
  • Fast installation.
  • Large choice of compatible substrates.
  • Excellent fire rating.
  • Superb weathering resistance.


System components:

  • RubberGard™ EPDM LSFR.
  • ISOGARD™ AK PIR Insulation.
  • ISOGARD™ MG PIR Insulation.
  • RESISTA™ AK PIR Insulation.
  • RESISTA™ MG PIR Insulation.
  • V-Gard™ Vapor Control layer.
  • SA-19 Primer.
  • Bonding Adhesive BA-2012 (for vertical membrane application).

General information

Color

Black

Finish

Smooth

Material

Rubber

Polyisocyanurate (PIR)

Shape

Rectangle

Length

30500 mm

Width

3050 mm

6100 mm

9150 mm

1220 mm

1525 mm

Height

1.1 mm

1.5 mm

Warranty description

Ten year

15 year

20 year

Uniclass

Ss_30_40_30_80 Single layer sheet warm roof covering systemsPrimary

CAWS

J42/10 Warm deck roof covering

J42/110 Warm deck roof covering

Specification data - Single layer sheet warm roof covering systems

Preparation

-

Horizontal work

SA-19 Primer.

Guidance for specification option:

Elevate SA-19 Primer is used to prime and prepare exterior concrete, wood, and metal surfaces to enhance the adhesion of Elevate V-Gard vapour control membrane. It's also used to prime seams when required.

Skirtings and vertical work

SA-19 Primer.

Guidance for specification option:

Elevate SA-19 Primer is used to prime and prepare exterior concrete, wood, and metal surfaces to enhance the adhesion of Elevate V-Gard vapour control membrane. It's also used to prime seams when required.

Air and vapour control layer

-

Type

V-Gard Vapor Control layer.

Guidance for specification option:

Elevate V-Gard Vapor Control Membrane is designed to be used as a vapour control layer in Elevate roofing systems. It consists of a reinforced aluminium foil with self-adhesive bituminous backing protected by a release film. The fibreglass reinforcement makes it suitable for applications that involve high mechanical stresses. The Elevate V-Gard membrane can be installed on concrete, wood and steel deck.

Attachment

Self-adhesive bituminous backing.

Insulation

-

Type

ISOGARD AK PIR Insulation.

Guidance for specification option:

Thermal conductivity: 0.023 W/m.K.

Thickness: 30–160 mm. Insert requirements.


Elevate ISOGARD AK insulation board consists of a closed-cell polyiso (PIR) foam core laminated on both sides to a gastight multi-layered aluminium complex.

ISOGARD MG PIR Insulation.

Guidance for specification option:

Thermal conductivity: 0.025–0.028 W/m.K.

Thickness: 30–160 mm. Insert requirements.


Elevate ISOGARD MG insulation board consists of a closed-cell polyiso (PIR) foam core laminated on both sides to a gasopen mineral glassfibre facer.

RESISTA AK PIR Insulation.

Guidance for specification option:

As per Fully Adhered Warm Roof System spec.


Thermal conductivity: 0.023 W/m.K.

Thickness: 30–160 mm. Insert requirements.


Elevate RESISTA AK insulation board consists of a closed-cell polyiso (PIR) foam core laminated on both sides to a gastight multi-layered aluminium complex.

RESISTA MG PIR Insulation.

Guidance for specification option:

As per Fully Adhered Warm Roof System spec.


Thermal conductivity: 0.025–0.028 W/m.K.

Thickness: 30–160 mm. Insert requirements.


Elevate RESISTA MG insulation board consists of a closed-cell polyiso (PIR) foam core laminated on both sides to a gasopen mineral glassfibre facer.

Manufacturer guidance

Consult the manufacturer's Technical Services Department for R-Value/U-value calculations as required.

Attachment

Loose laid.

Waterproof covering

-

Type

RubberGard™ EPDM LSFR Roofing Membrane 1.1 mm.

RubberGard™ EPDM LSFR Roofing Membrane 1.5 mm.

Manufacturer guidance

100% cured non-reinforced, Ethylene-Propylene-Diene Terpolymer (EPDM) synthetic rubber, manufactured in an ISO 9001 and ISO 14001 registered facility. Minimum unspliced width of 3.05 m.

Specification compliance:

UL Classified/ FM Approved.

ASTM D 4637/ EN 13956 (CE Mark).

7500 hrs of Artificial Ageing as per EN 1297.

Attachment

Loose laid.

Joints

Lap splices: 100 mm minimum overlap with 76 mm QuickSeam Splice Tape.

Upper protection layer

Geotextile protection mat, 200 g/m² (minimum) weight.

Surface protection

Geotextile protection mat, 200 g/m² (minimum) weight, and ballast layer, 50 kg/m² (minimum) weight.

Guidance for specification option:

The ballast layer such as pavers, pebbles, concrete, are placed on top of the geotextile protection mat. The minimum weight of ballast material required for this system is 50 kg/m2. More ballast weight may be required for roofs with higher wind load.

System accessories

QuickSeam Splice Tape.

QuickSeam FormFlash.

QuickSeam Flashing.

QuickSeam SA Flashing.

QuickSeam Reinforced Perimeter Fastening Strip.

QuickSeam Universal Pipe Flashing.

QuickSeam Conduit Flashing.

QuickSeam Penetration Pocket.

QuickSeam Walkway Pad.

QuickPrime Plus.

Lap Sealant HS.

All Purpose (AP) Fasteners

Heavy Duty (HD) Fasteners.

Splice Wash (SW-100).

Cleaner C-20.

Water-Block Seal (S-20).

Pourable Sealer S-10 (Parts A & B).

Coiled Metal Batten Strip.

Metal Batten Strip.

Termination Bar.

Corners

QuickSeam FormFlash (external corners) and folded internal corners.

Pipes

Pipe penetrations: QuickSeam FormFlash.

Pipe penetrations: QuickSeam Pipe boots and Conduit Flashing.

Outlets

Drains: Install Water Block Sealant between membrane and outlet bowl. Secure membrane mechanically to outlet using integral clamping ring.

Drains: Insert outlet bedded on Water Block Sealant. Secure and flash with QuickSeam FormFlash or SA Flashing.

Walls

Wall terminations: Termination bar, fastened with Water Block Sealant and Lap Sealant HS installed along top edge.

Guidance for specification option:

@200mm (maximum) o.c.

Wall terminations: Metal batten bar, fastened with surface mounted or inserted metal counter flashing protection.

Guidance for specification option:

@150mm (maximum) o.c.

Wall terminations: Metal capping or concrete coping stones.

Wall termination: Preformed metal edge trim.

Sustainability data

Country of product manufacture

United States

Material

Rubber

Polyisocyanurate (PIR)

Recyclability

An Environmental Product Declaration (EPD) is available upon request.

Third party certifications

BIM objects

Platform Compatible Version
Revit
-

1

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate

Elevate RubberGard EPDM Systems

EPD

EPD

Non-Reinforced EPDM

Literature

RubberGard™ EPDM

RubberGard™ EPDM

Similar products from Elevate EMEA

Rhenofol® PVC-P Mechanically Attached Warm Roof System - Single Ply PVC-P Warm Roof System

Rhenofol® PVC-P Mechanically Attached Warm Roof System - Single Ply PVC-P Warm Roof System

RubberGard™ EPDM Fully Adhered Warm Roof System

RubberGard™ EPDM Fully Adhered Warm Roof System

RubberGard™ EPDM Inverted Warm Roof System

RubberGard™ EPDM Inverted Warm Roof System

RubberGard™ EPDM Mechanically Attached Warm Roof System

RubberGard™ EPDM Mechanically Attached Warm Roof System

RubberGard™ EPDM SA Fully Adhered Warm Roof System - Self-adhesive EPDM Single Ply Roofing

RubberGard™ EPDM SA Fully Adhered Warm Roof System - Self-adhesive EPDM Single Ply Roofing

UltraPly™ TPO  Inverted Warm Roof System

UltraPly™ TPO Inverted Warm Roof System

UltraPly™ TPO Ballasted Warm Roof System

UltraPly™ TPO Ballasted Warm Roof System

UltraPly™ TPO Fully Adhered Warm Roof System

UltraPly™ TPO Fully Adhered Warm Roof System

UltraPly™ TPO Mechanically Attached Warm Roof System  - Single Ply Membrane Warm Roof System

UltraPly™ TPO Mechanically Attached Warm Roof System - Single Ply Membrane Warm Roof System