Verified by manufacturer 17 days ago
Façade system with up to 30 minutes' of fire protection.
Suitable for external use in protecting building roofs and inside areas against fire risks.
Fire-resistant façade, fully tested in accordance with EN 13643-3, providing 30 minutes' of fire resistance in the vertical and roof area, meeting the requirements of fire resistance classes EI30 and EW30. The multi-functional aluminium construction is visually identical to a standard Schüco façade allowing a harmonious façade design throughout with a 50 mm profile face width.
The system can be used in the vertical area due to its CE marking in accordance with EN 13830 and country-specific approvals are available for the skylight area.
Features and benefits:
Standards:
Color | Silver Other |
Finish | Powder-coated Anodized |
Material | Aluminium Glass |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | H11/110 Curtain walling |
System performance | Fire performance to BS EN 13501: F30; G30; EI30; EW30.Guidance for specification option: Consult manufacturer’s literature for further details. |
Framing | |
Frame members | Aluminium curtain wall frame sections, polyester powder-coated.Guidance for specification option: Insert colour requirements. Aluminium curtain wall frame sections, anodized.Manufacturer guidanceMinimum face width: 50 mm. Uf-value of frame: To EN ISO 10077-2, ≥1.1 W/m²K. |
Frame accessories | Manufacturer guidanceConsult manufacturer for options and insert requirements, or omit. |
Fasteners | Manufacturer's standard. |
Cladding units | |
Glass units | Manufacturer guidanceInsert requirements, 13–52 mm thick. |
Glazing accessories | Manufacturer guidanceInsert requirements or omit. |
Panels and facings | |
Material | Aluminium.Not required. |
Thermal insulation | Manufacturer guidanceInsert requirements or omit. |
Internal linings | Manufacturer guidanceInsert requirements or omit. |
Fasteners | Manufacturer's standard. |
Perimeter seals | Manufacturer's standard. |
System accessories | Manufacturer guidanceConsult manufacturer for options and insert requirements, or omit. |
Face width | 50 mm. |
Thermal transmittance (U-Value) | Manufacturer guidanceInsert requirements or consult manufacturer for values. Uf value of frame: ≥ .1 W/m²K. |
Burglar resistance | Manufacturer guidanceInsert requirements; up to EN 1627, RC 2 (WK2). |
Air permeability | To EN 12152, Class AE. |
Watertightness | To EN 12154, Class RE 1200. |
Resistance to wind load | To EN 12179, 1.2 kN/m². Guidance for specification option: Permissible load (in kN/m²), Positive wind load: +1.2, negative wind load: -1.2. Increased load (in kN/m²), Positive wind load: +1.8, negative wind load: -1.8. |
Impact resistance | To EN 14019, I5/ E5. |
Standards | To DIN 4102; EN 1364; EN 13501-2; DIN EN 13830. Guidance for specification option: CE marked. |
Label | Schueco ‘IoF’ ID tag with QR code. Guidance for specification option: Internet of facades (IoF) ID tag with unique QR code linked to the product data, ongoing maintenance instructions and installation records. |
Country of material origin | United Kingdom |
Material | Aluminium Glass |
Platform | Compatible | Version |
---|---|---|
- | 1 |
Add-On Construction (AOC)
Blast-resistant stick curtain walling façade system - FW 60+ XR
Concealed vent stick curtain walling façade system - FWS 60 CV
Fire-resistant Steel Stick Curtain Walling Façade System - VISS Fire
Fire-resistant stick curtain walling façade system - FW 60+ BF
Fire-resistant stick curtain walling façade system - FW50+ FR60