AIRTRAK® MV Mansard Ventilators - Roof Ventilation System

Verified by manufacturer 2 months ago

Airtrak MV150 Mansard Ventilator, pitch

Nicholson STS Ltd Variant:

Range of mansard ventilators for slate and tile roofing is used to introduce ventilation into a flat roof where it falls out onto a pitched roof.

Jump to:
+44 (0) 1763 295828 Website

Application

  • Suitable for use at the junction of a slated roof with metal, membrane or liquid roof coverings.
  • E Version: For increased resistance to both wind uplift in exposed locations and corrosion in coastal locations, the ventilator can be supplied in 1.0 mm-thick, 316 grade stainless steel. Where extreme weather conditions are likely, consideration should be given to providing more weathering cover to upstands and slating or tiling to improve the integrity of the detail.
  • FR Version: To reduce spread of fire through ventilation apertures, the ventilator can be supplied with an intumescent seal.


Note: Standard AIRTRAK® details assume moderate weather conditions. Small amounts of moisture may be admitted under heavy storm conditions. Where more severe weather conditions are likely, consideration should be given to increasing the vertical overlap dimension to upstands and to slating or tiling to improve the integrity of the weathering detail. For slate and tile details the manufacturer also recommends the use of the AIRTRAK® LPS where appropriate. Contact manufacturer for further technical help.

Description

Range of mansard ventilators for slate and tile roofing is used to introduce ventilation at the point where the flat roof falls out onto a pitched roof. This is predominately used to ventilate the flat roof area but can also be used to provide ventilation to the head of the slate or tile roof at the same time.


Features and benefits:

  • The stainless steel profile is covered by the flat roofing material or flashing.
  • Combined with a AIRTRAK® LPS low pitch soaker to maintain the integrity of the detail as the pitch reduces, selection guide below.
  • Can be combined with AIRTRAK® CF ClipFast clips where it is possible that the flashing might slip off the ventilator over time and the welt disengage from the lower edge.
  • Supplied pre-bent to a specified angle.


Product selection guide:

- Tiled roof applications:

  • 60-90° roof pitch: MV150.
  • 45-59° roof pitch: MV200.
  • 35-44° roof pitch: MV200 + LPS150.
  • 30-34° roof pitch: MV225 + LPS150.

- Slated roof applications:

  • 60-90° roof pitch: MV150.
  • 45-59° roof pitch: MV200.
  • 35-44° roof pitch: MV200 + LPS225.
  • 25-34° roof pitch: MV225 + LPS225.

General information

Material

Stainless steel

Glass Reinforced Plastic (GRP)

Guidance for specification option:

Insect mesh.

Shape

Rectangle

Length

1000 mm

Width

100 mm

180 mm

240 mm

275 mm

Warranty description

Ten year

Uniclass

Pr_30_59_29_82 Strip ventilatorsPrimary

CAWS

H62/47 Eaves

H65/355 Ventilated eaves – separated grilles/ trays

P10/110 Eaves roof ventilators for existing roofs

Specification data - Strip ventilators

Ventilation opening

25 mm continuous ventilation aperture.

Colour

Stainless steel.

Roof pitch

150 mm.

Grade

304.

Dimensions

1000 x 180 mm.

Guidance for specification option:

Unit length x overall girth.

Type

Standard.

Airtrak LPS Low Pitch Soaker

Not required.

Airtrak LPS150 Low pitch soaker for tiled roofs.

Guidance for specification option:

Not available with Airtrak MV150.

  • Material: 0.5 mm-thick aluminium.
  • W x L: LPS150: 175 x 1000 mm.

Airtrak LPS225 Low pitch soaker for slated roofs.

Guidance for specification option:

Not available with Airtrak MV150.

  • Material: 0.5 mm-thick aluminium.
  • W x L: LPS225: 250 x 1000 mm.

Airtrak CF ClipFast fixing clips

Not required.

Airtrak CF ClipFast clips, stainless steel.

Guidance for specification option:

70 x 60 mm, 0.6 mm thickness.

Airtrak CF ClipFast clips, copper.

Guidance for specification option:

70 x 60 mm, 0.5 mm thickness.

Manufacturer guidance

Fixing clip for securing lead flashings to the Airtrak ventilators to prevent flashing creep over time. Clips locate in the slots found in the lower edge of the ventilator; these slots are spaced at approximately 330 mm centres.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Recyclability

Recyclable at end of life

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

50 %

Literature

AIRTRAK Roof Void Ventilation System 2020

AIRTRAK Roof Void Ventilation System 2020

Case studies

AIRTRAK™ - Coal Drops Yard

AIRTRAK™ - Coal Drops Yard

Clifton Cathedral

Clifton Cathedral

AIRTRAK™ - St Johns Chapel

AIRTRAK™ - St Johns Chapel

Similar products from Nicholson STS Ltd

AIRTRAK®  CL Cladding Ventilator - Roof Ventilation System

AIRTRAK® CL Cladding Ventilator - Roof Ventilation System

AIRTRAK®  CS Comb Strip - Roof Ventilation System

AIRTRAK® CS Comb Strip - Roof Ventilation System

AIRTRAK®  CV Cheek Ventilator  - Roof Ventilation System

AIRTRAK® CV Cheek Ventilator - Roof Ventilation System

AIRTRAK®  IL Inline Ventilators - Roof Ventilation System

AIRTRAK® IL Inline Ventilators - Roof Ventilation System

AIRTRAK®  LB Layboard Ventilators - Roof Ventilation System

AIRTRAK® LB Layboard Ventilators - Roof Ventilation System

AIRTRAK®  PRV Pitched Roof Ventilator - Roof Ventilation System

AIRTRAK® PRV Pitched Roof Ventilator - Roof Ventilation System

AIRTRAK®  PV Pitched Valley Ventilators - Roof Ventilation System

AIRTRAK® PV Pitched Valley Ventilators - Roof Ventilation System

AIRTRAK®  VT Ventilated Edge Trim - Roof Ventilation System

AIRTRAK® VT Ventilated Edge Trim - Roof Ventilation System