Universal Louvre 3UL/SH
A roll‑formed triple‑bank system offering maximum rain defence and robust ventilation, suitable for facades in exposed or harsh conditions.
Suitable for applications such as:
Colt 3UL is a triple‑bank louvre system engineered for maximum rain defence without compromising airflow. Available in shallow (50 mm) or deep (100 mm) front blade pitches, it offers integrated drainage through hollow mullions and a clip‑on design to accommodate thermal movement. Suitable for exposed facades, plant rooms in harsh environments, and architectural screening where weather resistance is critical.
Features and benefits:
Performance Ratings
Materials and finishes:
Design and construction:
Accessories and options:
Installation and maintenance:
Testing and compliance:
Color | Silver Other |
Finish | Mill Embossed Manufacturer guidance[Finish, Anodised aluminium, polyester powder coated, acrylic, PVF2, and Stucco and HPS 200] |
Material | Aluminium Steel Stainless steel |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | H11/140 Louvres L10/490 Roof ventilators L10/650 Metal louvres |
Classification data | |
Screen framing | Aluminium. Mild steel. Stainless steel. |
Louvres | |
Type | As screen framing. |
Operation | Triple bank shallow section, front louvres at 50 mm pitch. |
Blanking panels | None. Single skin aluminium panel, mill finish. Single skin aluminium panel with external decorative polyester powder paint finish to match louvres. Insulated panel. |
Acoustic panels | |
Facing | None. Type R acoustic louvre panels. Guidance for specification option: Optimum acoustic performance with normal pressure drop. Type LP acoustic louvre panels. Guidance for specification option: Normal acoustic performance with minimum pressure drop. |
Banked | |
First bank | None. Type R acoustic louvre panels. Guidance for specification option: Optimum acoustic performance with normal pressure drop. Type LP acoustic louvre panels. Guidance for specification option: Normal acoustic performance with minimum pressure drop. |
Second bank | None. Type R acoustic louvre panels. Guidance for specification option: Optimum acoustic performance with normal pressure drop. Type LP acoustic louvre panels. Guidance for specification option: Normal acoustic performance with minimum pressure drop. |
System accessories | None. Visible frame double door. Visible frame single door. Concealed frame double door. Concealed frame single door. Turret unit(s). Triangular panel(s). Circular panel(s). |
Guards | None. Aluminium bird guard. Galvanized steel bird guard. Aluminium fly guard. Stainless steel insect mesh. Manufacturer guidanceLouvre design should allow for additional resistance to airflow and reduced flow rate. |
Dimensions | Guidance for specification option: Insert requirements or drawing/ schedule reference. |
Configuration | Horizontal. Horizontal inverted. Vertical. |
Texture | Plain. Perforated. Stucco embossed. |
Finish | Mill aluminium. Anodized. Guidance for specification option: Consult manufacturer for options and insert requirements. Polyester powder coated, RAL (total coverage). Guidance for specification option: Consult manufacturer for options and insert colour requirement. All exposed surfaces and edges of components and assemblies are coated, excluding fixings and rivets. Polyester powder coated, RAL (partial coverage). Guidance for specification option: Consult manufacturer for options and insert colour requirement. Only external louvre blades, frames, corners and cills are coated, the remaining components are mill finish. PVF2 (total coverage). Guidance for specification option: Consult manufacturer for options and insert colour requirement. All exposed surfaces and edges of components and assemblies are coated, excluding fixings and rivets. PVF2 (partial coverage). Guidance for specification option: Consult manufacturer for options and insert colour requirement. Only external louvre blades, frames, corners and cills are coated, the remaining components are mill finish. |
Performance | Aerodynamic: minimum performance coefficient (Cv) of 0.277 (inlet) and 0.22 (extract); Rain defence: Class A - up to 3.5 m/s suction velocity Guidance for specification option: Aerodynamic performance is equivalent to Class 3 to HEVAC 4th Edition. |
Material | Aluminium Steel Stainless steel |