NBS Source
I'm a manufacturer

Type VF Ventilating Flashing

Verified by manufacturer 7 months ago

Cavity Trays Ltd

Lead ventilating flashing with bonded sandwich base through which air can pass permitting breathing at the intersection being flashed.

Jump to:
+44 (0)1935 474769 Website

Application

To provide flashing and ventilation at roof and wall intersections.

Description

Flashing for the intersection between a mono pitch roof and masonry wall, and to introduce the requisite regulation airflow in one operation.


Features and benefits:

  • It is suitable for roof pitches from 22.5–80°.
  • A breathing base layer bonded to the underside permits air to enter and exit between roof space and flashing.
  • The base also acts as a filter against the entry of insects.
  • Packaged solution for regulation compliance.
  • Code 4 British Standard lead to BS EN 12588:2006.

General information

Color

Grey

Guidance for specification option:

Natural lead.

Finish

Smooth

Material

Metal

Guidance for specification option:

To BS EN 12588.

Shape

Other

Size

Guidance for specification option:

300 mm wide with pre-creased lengths.

Length

1200 mm

Width

225 mm

Height

150 mm

Warranty description

20 year

Uniclass

Pr_30_59_29_02 Abutment ventilatorsPrimary

CAWS

H60/675 Top edge ventilated abutments

H60/72 Top edge ventilated abutments

Specification data - Abutment ventilators

Purpose

Flashing and ventilation at roof and wall intersections.

Ventilation opening

5000 mm².

Colour

Grey.

Guidance for specification option:

Natural lead coloured.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Recyclability

Yes

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

100 %

Literature

Ventilation Product Guide

Ventilation Product Guide

Protecting the Building Envelope Volume 28 (cavity tray, damp proofing, ventilation and cavity closers)

Protecting the Building Envelope Volume 28 (cavity tray, damp proofing, ventilation and cavity closers)