Verified by manufacturer 7 days ago
RB70-S-60(50)
BSI Kitemark
Certificate type
EPD
Certificate type
ISO 9001 Quality Management
Certificate type
UK Conformity Assessed (UKCA)
Certificate type
TRADELINE Resilient Bar partitions are non-load bearing that achieves high levels of sound insulation.
Hotels, residential properties, student accommodation.
TRADELINE Resilient Bar systems are lightweight, non
load-bearing, friction fit systems. They can be used within
all sectors.
Due to the inclusion of TRADELINE RB565
Resilient Bars on one side of the partition create a higher
level of separation between the C stud and plasterboard
lining thereby achieving superior levels of sound
insulation performance.
Designed to give the potential to satisfy acoustic requirements for Part E of the Building regulations. Due to the high reliance on workmanship, we only recommend when the requirement is 43 DnT, w + ctr i.e. material change of
use, student accommodation, hotels etc.
Sound performance up to 61 RwdB, 90 minutes fire and Severe Duty
Structural performance:
Fire performance:
Acoustic performance:
Installing framing for partitions:
Length | Bespoke |
Width | 148 mm 149 mm |
Height | Bespoke |
Uniclass | |
CAWS | K10/30 Metal stud K10/125 Metal stud partition system |
Product range |
Framing | Tradeline 'C' Stud with Resbar, 70 mm. |
Insulation | Acoustic partition roll, 50 mm. |
Linings | |
Inner layers | Siniat GTEC dB Board, 15 mm. |
Face layer | Siniat GTEC dB Board, 15 mm. |
Fasteners | Tradeline Drywall Screws. |
Joint treatment | Tradeline Joint Tape.Tradeline Paper Joint Tape.Tradeline Light Weight All Purpose Joint Compound.Tradeline Metal Corner Tape.Tradeline Flexible Metal Corner Tape.Tradeline Scrim Tape.Tradeline Drywall Self-Adhesive Joint Tape. |
System accessories | Tradeline Acoustic Intumescent Sealant.Tradeline PB24 Partition Brace.Tradeline FS24 Flat Bracing Strip.Tradeline ASP19B Plywood Service Support Plates. |
Fire resistance | To BS 476:1987:Part 22, 90/ 90 minutes (Integrity/ Insulation). |
Partition height | Guidance for specification option: Insert requirement, maximum 4200 mm (at 600 mm centres). Calculated based on a limiting deflection of L/240 at 200 Pascals. |
Nominal thickness | 148 mm. Manufacturer guidanceOptimum system thickness. Note that if a greater partition thickness is required, this may improve the sound reduction index (Rw) - consult manufacturer for details. |
Calculated weighted sound reduction index (Rw) | 61 (-2;-7) Rw dB (C;Ctr). |
Centres | 600 mm. |
StrengthGrade | Severe duty. |
Head/ Floor channel | Tradeline Standard Track. Guidance for specification option: Used for partition heights under 4 m. Available in 50, 52, 62 or 72 mm wide. 25 mm flange. Tradeline 32 mm Leg Track. Guidance for specification option: Used for partition heights under 4 m. Available in 52, 62, 72, 94 or 148 mm wide. 32 mm flange. Tradeline Deep Track. Guidance for specification option: Used for partition heights between 4 m and 8 m. Can be used as a head track where a deflection head of up to 30 mm is needed. Available in 52, 62, 72, 94 or 148 mm wide. 50 mm flange. Tradeline Extra Deep Track. Guidance for specification option: Used for partition heights between 8 m and 10.2 m. Can be used as a head track where a deflection head of up to 45 mm is needed. Available in 72, 94 or 148 mm wide. 70 mm flange. |
Standards | To BS 5234-2:1992, BS 476:1987:Part 22, BS EN ISO 10140-2: 2010. |
BSI Kitemark
BIM Level 2 Kitemark - For Design and Construction Phase
BSI Kitemark
BSI Kitemark™ for BIM Objects
EPD
Environmental Product Declaration EPD - Drylining
ISO 9001 Quality Management
ISO 9001:2015 Quality Management System
UK Conformity Assessed (UKCA)
UKCA Declarations of Performance - Drylining
SPEEDLINE Shaft Encasement Systems Utilising British Gypsum Board
SPEEDLINE Shaft Encasement Systems Utilising Knauf Board
SPEEDLINE Shaft Encasement Systems Utilising Siniat Board
SPEEDLINE Single Frame Acoustic Stud Partition Systems Utilising British Gypsum Board
SPEEDLINE Single Frame Acoustic Stud Partition Systems Utilising Knauf Board
SPEEDLINE Single Frame Acoustic Stud Partition Systems Utilising Siniat Board
SPEEDLINE Single Frame Partition Systems Utilising British Gypsum Duraline
SPEEDLINE Single Frame Partition Systems Utilising British Gypsum FireLine
SPEEDLINE Single Frame Partition Systems Utilising British Gypsum SoundBloc
SPEEDLINE Single Frame Partition Systems Utilising British Gypsum WallBoard