Range of thermally insulated roof outlets with bodies made of rigid polyurethane integral foam.
For main and emergency drainage to DIN EN 12056-3 and DIN 1986-100 for large used and unused flat roofs.
Range of Thermally Insulated Roof Outlets featuring bodies made of rigid polyurethane, designed for both main and emergency drainage applications.
The SitaStandard Vertical outlet is constructed from thermally insulated polyurethane and complies with DIN EN 1253-2 standards. Available in nominal widths of DN 70, DN 100, DN 125, DN 150, and DN 200, it offers a direct connection to pipes with push-fit sockets for gravity drainage. It includes a large integrated connection sleeve (495 mm x 495 mm) suitable for roof waterproofing membranes and liquid applied systems, and a fixing ring to secure the connection sleeve and support the included gravel trap.
Features and benefits:
Color | Black Beige |
Material | Polyurethane (PUR) |
Shape | Circle Square |
Length | Bespoke |
Width | 70 mm 100 mm 125 mm 150 mm 200 mm Manufacturer guidancePipe DN. |
Height | Bespoke |
Warranty description | Six year |
Uniclass | |
CAWS | R10/26 Proprietary rainwater outlets R10/365 Proprietary rainwater outlets |
Roof construction | |
Form | Guidance for specification option: Insert details. |
Roof insulation thickness | Guidance for specification option: Insert details. Outlet is suitable for bridging all insulation thicknesses from 60 to 520 mm. |
Material | Body: Rigid polyurethane integral foam. |
Grating | Domed. |
Spigots | DN70, outer diameter 75 mm.Guidance for specification option: Pipe connection length: 65 mm. DN100,outer diameter 110 mm.Guidance for specification option: Pipe connection length: 67 mm. DN125,outer diameter 125 mm.DN150,outer diameter 160 mm.Guidance for specification option: Pipe connection length: 77 mm. DN200,outer diameter 200 mm.Guidance for specification option: Pipe connection length: 101 mm. Manufacturer guidanceOpening/ core borehole: 250 mm. Consult manufacturer's literature for full details. |
Integral accessories | Bitumen sleeve 495 x 495 mm. |
Orientation | Vertical. |
Standard | For main and emergency drainage to DIN EN 12056-3 and DIN 1986-100 for large used and unused flat roofs. |
Accessories | Guidance for specification option: Consult manufacturer for options and insert requirements, or omit. |
Reaction to fire | Euroclass E/ B2 normal flammability. |
Country of material origin | Germany |
Country of product manufacture | Germany |
Material | Polyurethane (PUR) |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 13.4 kg CO₂ eq/unit |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 1 | |
- | 1 |
BRE Certificate
BRE Rainwater Outlet Thermal Performance Certification
ISO 14001 Environmental Management Systems
ISO 14001 Environmental Management Systems
ISO 9001 Quality Management
ISO 9001:2015 Quality Management System
TUV - Safety and Quality Report
LGA Certification - EN 1253-2:2015
EPD
Sita Flat-Roof Outlets – EPD
DN70 SitaStandard Vertical Roof Outlet - Technical Drawing
DN100 SitaStandard Angled Roof Outlet - Technical Drawing
DN100 SitaStandard Vertical Roof Outlet - Technical Drawing
DN125 SitaStandard Angled Roof Outlet - Technical Drawing
DN125 SitaStandard Vertical Roof Outlet - Technical Drawing
DN150 SitaStandard Vertical Roof Outlet - Technical Drawing
DN200 SitaStandard Vertical Roof Outlet - Technical Drawing
DN70/DN100 SitaStandard Stepped Roof Outlet - Technical Drawing
DN70 SitaStandard Angled Roof Outlet - Technical Drawing
60-520mm SitaStandard Extension Unit - Technical Drawing
60-220mm SitaStandard Extension Unit - Technical Drawing
DN100 SitaStandard Fluid Angled Roof Outlet - Technical Drawing
DN100 SitaStandard Fluid Vertical Roof Outlet - Technical Drawing
DN125 SitaStandard Fluid Vertical Roof Outlet - Technical Drawing
DN125 SitaStandard Fluid Angled Roof Outlet - Technical Drawing
DN150 SitaStandard Fluid Vertical Roof Outlet - Technical Drawing
DN200 SitaStandard Fluid Vertical Roof Outlet - Technical Drawing
DN70/DN100 SitaStandard Liquid Stepped Roof Outlet - Technical Drawing
DN70 SitaStandard Fluid Angled Roof Outlet - Technical Drawing
DN70 SitaStandard Fluid Vertical Roof Outlet - Technical Drawing
60-160mm SitaStandard Extension Unit - Technical Drawing
SitaCompact Balcony & Terrace Rainwater Outlet - Thermally Insulated Roof Outlet
SitaEasy Go Parapet Rainwater Outlet - Parapet Outlet
SitaEasy Parapet Rainwater Outlet - Parapet Outlet
SitaGreen Green Roof Inspection Chambers - Modular Inspection Shaft for Area Outlet
SitaRetention Blue Roof Flow Restrictor - Controlled Rainwater Drainage Retainers
SitaSani® Refurbishment Rainwater Outlet - Thermally Insulated Roof Outlet
SitaStandard Extension Unit
SitaTrendy Extension Unit
SitaTrendy Rainwater Outlet - Thermally Insulated Roof Outlet