NBS Source
I'm a manufacturer
Compare variants

SitaSani® Refurbishment Rainwater Outlet - Thermally Insulated Roof Outlet

Verified by manufacturer 2 months ago

SitaSani® 63 refurbishment outlet

Sita Bauelemente GmbH Variant:
Third party certifications:
  • ISO 9001 Quality Management

    Certificate type

  • TUV - Safety and Quality Report

    Certificate type

  • EPD

    EPD

    Certificate type

Range of thermally insulated roof outlets for refurbishment projects. This compensates for the existing waterproofing and insulation layers to the roof outlet or downpipe.

Jump to:
BOS
07402239777 Website

Application

For main and emergency drainage and for refurbishment into the downpipe of old roof outlets in flat and slightly pitched, used and unused roof surfaces.

Multi-compatible for almost any make of roof outlet.

Description

Range of thermally insulated roof outlets for refurbishment projects, with long spigot and sealing ring. This compensates for the existing waterproofing and insulation layers to the roof outlet or downpipe in place. 


Features and benefits:

  • Backflow safe up to a water column of 2 metres.
  • To refurbish roof outlets and for refurbishment down into the downpipe.
  • With connection sleeve of choice or screw-on flange construction.
  • Multi-compatible for almost any make of roof outlet; can solve almost any refurbishment task.
  • Various sealing rings are used to match the existing internal diameters.
  • Foamed-in and additionally fixed connecting sleeve of choice offers a homogeneous connection to the roofing membrane.
  • Quick installation time.
  • Thermally insulated.
  • Not sensitive to the weather (UV/ IR radiation, rain/ snow, temperature, ozone, etc.).
  • Impact and shock resistant.
  • Durable.

General information

Color

Black

Beige

Material

Polyurethane (PUR)

Bitumen

PVC

Shape

Circle

Square

Length

Bespoke

Width

Bespoke

Height

Bespoke

Warranty description

Six year

Uniclass

Pr_65_50_35_37 Gravity rainwater outletsPrimary

CAWS

R10/26 Proprietary rainwater outlets

R10/365 Proprietary rainwater outlets

Specification data - Gravity rainwater outlets

Roof construction

-

Form

Guidance for specification option:

Insert details.

Roof insulation thickness

Guidance for specification option:

Insert details. Outlet is suitable for bridging all insulation thicknesses from 60 to 520 mm.

Material

Body: Polyurethane.

Guidance for specification option:

Thermally insulated, to DIN EN 1253-2.

Manufacturer guidance

See Integral accessories and/ or manufacturer's literature for details of other components.

Grating

Domed.

Spigots

DN63 (outer diameter 63 mm; height 550 mm).

Guidance for specification option:

For refurbishment of internal diameters of 68–86 mm.

Manufacturer guidance

Consult manufacturer's literature for full details.

Integral accessories

Large foamed-in connection sleeve of choice (495 x 495 mm); dome grate; lubricant; fixing ring; multi-lip sealing ring.

Guidance for specification option:

  • Connection sleeve for homogeneous connection of the roofing membrane - insert requirements.
  • Fixing ring for addition securing of the connection sleeve and to hold the dome grate.
  • Multi-lip sealing ring for backflow protection.

Orientation

Vertical.

Accessories

Guidance for specification option:

Consult manufacturer's literature for options and insert requirements.

Reaction to fire

Euroclass E/ B2 normal flammability.

Sustainability data

Country of material origin

Germany

Country of product manufacture

Germany

Material

Polyurethane (PUR)

Bitumen

PVC

Embodied carbon

A1-A3 (production stage) as defined in BS EN 15804

13.4 kg CO₂ eq/unit

Third party certifications

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
Revit
-

1

IFC
-

1

Third party certifications

ISO 9001 Quality Management

ISO 9001 Quality Management

ISO 9001:2015 Quality Management System

TUV - Safety and Quality Report

TUV - Safety and Quality Report

LGA Certification - EN 1253-2:2015

EPD

EPD

Sita Flat-Roof Outlets – EPD