Verified by manufacturer 1 month ago
Curtain wall system with enhanced thermal performance.
A curtain wall system which has been designed to enhance thermal performance meaning the system can exceed current building regulations. It is a stick type front loaded system using spring pins and a specially designed cleat which allows square cutting throughout.
Features and benefits:
Material | Aluminium Guidance for specification option: Alloy. |
Shape | Square Rectangle Other |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | H11/110 Curtain walling |
Product range |
Framing | |
Frame members | Aluminium alloy curtain wall frame sections.Guidance for specification option: Aluminium alloy 6060, 6063 or 6083 (for improved strength). T6 to BS EN 755-9 or BS EN 12020-2. |
Cladding units | |
Glass units | Insulated glass units (IGUs).Guidance for specification option: Insert required thickness.
|
System accessories | Aluminium/ co extruded plastic pressure plate.Guidance for specification option: Fixed to mullions and transoms at a maximum of 25 mm from ends and at a maximum of 150 centres. |
Type | SF050. SF080. SF100. SF125. SF150. |
Vertical | SMR998. SMR997. SCW002. SCW008. As drawing. Guidance for specification option: Insert details. |
Horizontal | SMR997. SCW055. SCW003. SCW007. As drawing. Guidance for specification option: Insert details. |
Perimeter edge/ thermal break | Extruded to BS 7619. |
Gasket | Manufactured in accordance with BS 3734. |
Air permeability | 600 Pa. Guidance for specification option: Tested to CWCT specification sequence B and in accordance with BS EN 13830. |
Watertightness | 600 Pa. Guidance for specification option: Tested to CWCT specification sequence B and in accordance with BS EN 13830. |
Wind resistance | 2400 Pa. Guidance for specification option: Tested to CWCT specification sequence B and in accordance with BS EN 13830. |
Mullion | Guidance for specification option: Insert requirents. Mullion size dependent on wind load, mullion centres and tie back positions. Transom size subject to span and glass weight and in-conjunction with architectural design. |
Country of product manufacture | United Kingdom |
Recyclability | 100 |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
Revit 2016 | 1 | |
- | 1 |