Verified by manufacturer 2 months ago
EPD
Certificate type
BBA Agrément Certificate
Certificate type
A mechanically attached warm roof system based on the use of Rhenofol® PVC-P single ply roofing membrane.
Rhenofol® PVC-P Polyester reinforced single ply membrane system is suitble for warm roof constructions on commercial roofing projects. The system may be mechanically attached to several deck types using approved fasteners and plates.
The Rhenofol® PVC-P Mechanically Attached Warm Roof System is a lightweight roof system. The highly durable polyester reinforced membrane is mechanically attached to the structural deck using approved fasteners and plates.
Features and benefits:
System components:
Color | Grey |
Finish | Smooth |
Material | Polyvinyl chloride (PVC) |
Shape | Rectangle |
Length | 15000 mm 20000 mm |
Width | 1030 mm 1500 mm 2050 mm |
Height | 1.2 mm 1.5 mm 1.8 mm 2.0 mm Manufacturer guidanceThickness. |
Warranty description | 20 year |
Uniclass | |
CAWS | J42/10 Warm deck roof covering J42/110 Warm deck roof covering |
Preparation | |
Horizontal work | The substrate will be securely fixed, clean, dry, smooth and free of contaminants such as greases, animal fats, coal tar and oil-based products. All sharp edges, nibs and rough surfaces which could damage the membrane will be removed or otherwise isolated. |
Air and vapour control layer | |
Type | Elevate V-Gard ALU1500 Self-Adhesive Air & Vapour Control layer.Guidance for specification option: Self-adhesive to approved substrates (wood, steel). Elevate V-Gard PE 200 Air & Vapour Control layer (Low Humidity Class Buildings Only) .Guidance for specification option: Loose laid over the approved substrate, joints are taped using V-Gard PE Seam Tape. Elevate V-Gard PE 200 E Air & Vapour Control layer (Low Humidity Class Buildings Only) .Guidance for specification option: Loose laid over the approved substrate, joints are taped using V-Gard PE Seam Tape. Elevate V-Gard PE 400 Air & Vapour Control layer (Low Humidity Class Buildings Only) .Guidance for specification option: Loose laid over the approved substrate, joints are taped using V-Gard PE Seam Tape. |
Attachment | As Type.Guidance for specification option: See Type guidance above for details. |
Insulation | |
Type | ISOGARD™AK PIR insulation.Guidance for specification option: Available in thickness: 30–160 mm; insert requirements. Thermal conductivity: 0.023 W/m·K. Elevate ISOGARD AK insulation board consists of a closed-cell polyiso (PIR) foam core laminated on both sides to a gastight multi-layered aluminium complex. |
Attachment | Insulation plates and fasteners (after laying waterproof covering).Guidance for specification option: Insulation boards or sections of boards, which are not sufficiently secured to the substrate, should be fixed with additional fasteners (minimum two fasteners per m²) prior to laying the roof membrane. |
Separating layer | ISOGARD™ HD Cover Board.DensDeck® Prime Cover Board.Not required.Manufacturer guidanceCover boards may be placed between the insulation layer and the waterproofing membrane, usually in cases where an insulation material with a low compressive strength is specified. Consult manufacturer for details and recommendations as required. |
Waterproof covering | |
Type | Rhenofol® CV PVC-P Membrane, 1.2 mm.Guidance for specification option: Weight: 1.47 kg/m². Can be supplied in rolls of:
Rhenofol® CV PVC-P Membrane, 1.5 mm.Guidance for specification option: Weight: 1.85 kg/m². Can be supplied in rolls of:
Rhenofol® CV PVC-P Membrane, 1.8 mm.Rhenofol® CV PVC-P Membrane, 2.0 mm.Manufacturer guidance
|
Attachment | Insulation plates and fasteners.Guidance for specification option: The fastening pattern is chosen in line with the manufacturer's installation guidelines and to accommodate for wind loading. Manufacturer's standard: Self-tapping screws with washer, to suit substrate/ insulation thickness. |
Joints | Hot air welded seam.Rhenofol® welding paste system. |
Accessories | None.Rhenofol® round standing seam section.SA-19 Primer.Guidance for specification option: For priming seams. |
Surface protection | Rhenofol® paving tiles.None. |
System accessories | None.Rhenofol® C detailing membrane.Rhenofol® 90° inside corner.Rhenofol® 90° outside corner.Rhenofol® collar.Rhenofol® universal collar.FDT collars for FDT VarioGully.FDT gravel/leaf guard.FDT leaf guard.FDT screw-in gravel/leaf guard retainer ring.FDT oval sealing ring.FDT roll ring.FDT lip seal.Rhenofol® contact adhesive 20.Rhenofol® paste.FDT support surround.Rhenofol® sheet metal flashing.Rhenofol® thinner D.Manufacturer guidanceSee below for drainage options. |
Drainage | Not required. FDT VarioGully. FDT emergency overflow drain. FDT rainwater outlet. FDT parapet outlet. |
Corners | Corners formed using Rhenofol® CV membrane with Rhenofol® 90° inside/ outside corners. |
Pipes | Pipe penetrations: Flash pipe with Rhenofol® C PVC-P membrane. |
Walls | Wall terminations: Termination bar, fastened with Water Block Sealant and GP Sealant installed along top edge. Wall terminations: Metal capping or concrete coping stones. Wall terminations: Hot air welded to Rhenofol® sheet metal flashing. Wall terminations: Using counterflashing. |
Country of material origin | Germany |
Country of product manufacture | Germany |
Material | Polyvinyl chloride (PVC) |
Manufacturing plant location | |
Recyclability | An Environmental Product Declaration (EPD) is available upon request. |
RubberGard™ EPDM Ballasted Warm Roof System
RubberGard™ EPDM Fully Adhered Warm Roof System
RubberGard™ EPDM Inverted Warm Roof System
RubberGard™ EPDM Mechanically Attached Warm Roof System
RubberGard™ EPDM SA Fully Adhered Warm Roof System - Self-adhesive EPDM Single Ply Roofing
UltraPly™ TPO Inverted Warm Roof System
UltraPly™ TPO Ballasted Warm Roof System
UltraPly™ TPO Fully Adhered Warm Roof System
UltraPly™ TPO Mechanically Attached Warm Roof System - Single Ply Membrane Warm Roof System