Verified by manufacturer 7 months ago
Flexible hydrocarbon resistant membrane.
HYDRORPUFE 6000 should be loose laid to the prepared sub-base, taking special care to ensure the membrane is not punctured during the installation phase. Adjacent sheets of membrane should be lapped by 150 mm. HCR Butyl Tape is used between the joints and then HCR Foil Girth Tape should be used to over lap the joint.
HYDROPRUFE 6000 is a high-performance high density polythene membrane which is suitable for use on brownfield sites that require protection from dangerous contaminants and ground gases.
HYDROPRUFE 6000 has outstanding chemical resistance and mechanical properties, making it suitable for use where high levels of total petroleum hydrocarbons are present.
Color | Black |
Finish | Matt |
Material | Polyethylene |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | 25 year |
Uniclass | |
CAWS | D21/350 Gas-retardant membrane D21/38 Gas-retardant membranes J40/120 Loose-laid plastics or rubber sheet damp-proofing J40/130 Loose-laid plastics or rubber sheet oversite damp-proofing J40/140 Loose-laid plastics or rubber sheet gas-retardant membranes J40/20 Loose-laid plastics or rubber sheet damp-proofing J40/30 Loose-laid plastics or rubber sheet oversite damp-proofing J40/35 Loose-laid plastics or rubber gas-retardant membranes |
Product range |
Material | High-density polyethylene (PE-HD). |
Purpose | Hydrocarbon and gas-resistant membrane/ damp proof membrane. |
Standard | BS EN 14414. |
Performance characteristics | |
Tensile strength (minimum) | >850 N/50 mm (to BS EN 12311-2). |
Physical properties | |
Colour | Black. |
Dimensions | |
Thickness (minimum) | 1 mm.1.5 mm. |
Width (minimum) | 2.5 m. |
Roll length (minimum) | 35 m. |
Puncture resistance | 3.2 kN (to BS EN 12236). |
Tear strength | 140 N. |
Density | 0.95 g/cm³. |