ITHERM E TAKKA is a concrete subfloor underfloor heating insulation system that enables fast installation and consistent heat distribution prior to screeding.
The ITHERME TAKKA system is installed by laying the EPS insulation panels onto the concrete subfloor or PIR insulation, fixing the heating pipework using barbed staples in accordance with the design layout, fitting perimeter expansion foam, and completing the installation with a suitable screed before applying the final floor finish.
The ITHERME TAKKA system is an underfloor heating insulation and pipe fixing solution designed for use on concrete subfloors. It features a high-density EPS insulation panel with a pre-bonded woven membrane that supports secure pipe fixing and accurate pipe layout prior to screeding. Engineered for straightforward installation and design flexibility, the system supports consistent heat distribution across the floor area and is suitable for a wide range of new build applications.
Features and benefits:
Color | White |
Finish | Other Guidance for specification option: Floor finish (by others). |
Material | Polypropylene Expanded polystyrene (EPS) |
Shape | Other |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | T90/478 Underfloor electric heating cables T90/450 Insulation to pipework to control heat loss T9/336 Insulation for heating system pipework |
Classification data | |
Heat source | Manufacturer guidanceInsert requirements or omit. |
Pumps | Manufacturer guidanceInsert requirements or omit. |
Pipework | |
Distribution | Itherme VE-FLEX pipes, 16 x 2 mm. Guidance for specification option: PE-RT/EVOH/PE-RT, five layer oxygen diffusion barrier pipe to DIN 4726 (SKZ,KOMO Cert). |
Underfloor | Itherme VE-FLEX pipes, 16 x 2 mm. Guidance for specification option: PE-RT/EVOH/PE-RT, five layer oxygen diffusion barrier pipe to DIN 4726 (SKZ,KOMO Cert). |
Jointing materials | Manufacturer guidanceInsert requirements or omit. |
Insulation | Itherme TAKKA EPS 150 kpa insulation. Guidance for specification option: With grid pattern, pre-bonded woven membrane. PIR insulation (supplied by others). |
Pipe accessories | Manufacturer guidanceInsert requirements or omit. |
Pipe supports | ITherme TAKKA staple. |
Accessories | Not required. Decoupling membrane (supplied by others). |
Floor components | Screed (by others in accordance with specification). 2-3-5 mm self levelling compound (by others). Guidance for specification option:
|
Floor finish | Manufacturer guidanceSupplied by others, insert requirements. |
Material | Polypropylene Expanded polystyrene (EPS) |