NBS Source
I'm a manufacturer

Highly Thermally Insulated Steel Stick Curtain Walling Façade System - VISS 60

Verified by manufacturer 3 days ago

Schueco UK Ltd

Highly thermally insulated mullion/ transom construction for skylights and vertical facades.

Jump to:
+44 (0)1908 282111 Website

Application

Suitable for all types of sloped glazing from simple mono-pitch roofs to the complex geometries of gable roofs and pyramids.

Description

Highly thermally insulated mullion/ transom construction for skylights and vertical facades with narrow face widths ensuring maximum light penetration.


Features and benefits:

  • Variety in design due to wide range of aluminium cover caps.
  • Special profiles for wall attachments and insert units.
  • Elegant intersection of skylight and vertical facade.
  • High level of thermal insulation.
  • 50 mm version (VISS 50) also available; specified separately.
  • TRAV-tested.
  • CE conformable.
  • All assemblies to include a Schueco Internet of Facades (IoF) ID tag with unique QR code linked to the product data, ongoing maintenance instructions and installation records creating a project’s digital twin.

General information

Color

Silver

Other

Finish

Anodized

Powder-coated

Painted

Material

Steel

Glass

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Ss_25_10_20_85 Stick curtain walling systemsPrimary

CAWS

H11/110 Curtain walling

Specification data - Stick curtain walling systems

Framing

-

Frame members

Steel curtain wall frame sections, polyester powder-coated.

Steel curtain wall frame sections, anodized.

Steel curtain wall frame sections, painted.

Frame accessories

-

Manufacturer guidance

Consult manufacturer for options and insert requirements, or omit.

Fasteners

Manufacturer's standard.

Cladding units

-

Glass units

-

Manufacturer guidance

Insert requirements, including overall thickness, 20–40 mm.

Glazing accessories

-

Manufacturer guidance

Consult manufacturer for options and insert requirements, or omit.

Panels and facings

-

Material

Steel.

Not required.

Thermal insulation

-

Manufacturer guidance

Consult manufacturer for options and insert requirements, or omit.

Internal linings

-

Manufacturer guidance

Consult manufacturer for options and insert requirements, or omit.

Fasteners

Manufacturer's standard.

Perimeter seals

Manufacturer's standard.

System accessories

-

Manufacturer guidance

Consult manufacturer for options and insert requirements, or omit.

Face width

60 mm.

Guidance for specification option:

Minimum.

Thermal transmittance (U-Value)

-

Manufacturer guidance

Insert requirements or consult manufacturer for values.

Label

Schueco ‘IoF’ ID tag with QR code.

Guidance for specification option:

Internet of facades (IoF) ID tag with unique QR code linked to the product data, ongoing maintenance instructions and installation records.

Sustainability data

Country of material origin

United Kingdom

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

23 %

BIM objects

Platform Compatible Version
Revit
-

1