Verified by manufacturer 3 days ago
Flexible fire-resistant facade.
Suitable for vertical facades in all tested fire resistance classes for internal and external use.
Steel profile system for all standard fire-resistance classes featuring slimline face widths with large areas of glass providing maximum light penetration and the highest level of transparency.
Features and benefits:
Color | Silver Other |
Finish | Anodized Powder-coated Painted |
Material | Steel Glass |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Uniclass | |
CAWS | H11/110 Curtain walling |
Framing | |
Frame members | Steel curtain wall frame sections, polyester powder-coated.Guidance for specification option: Insert colour requirements. Steel curtain wall frame sections, anodized.Steel curtain wall frame sections, painted.Guidance for specification option: Insert colour requirements. |
Frame accessories | Manufacturer guidanceConsult manufacturer for options and insert requirements, or omit. |
Fasteners | Manufacturer's standard. |
Cladding units | |
Glass units | Manufacturer guidanceInsert requirements, including overall thickness, 5–70 mm. |
Glazing accessories | Manufacturer guidanceConsult manufacturer for options and insert requirements, or omit. |
Panels and facings | |
Material | Steel.Not required. |
Thermal insulation | Manufacturer guidanceConsult manufacturer for options and insert requirements, or omit. |
Internal linings | Manufacturer guidanceConsult manufacturer for options and insert requirements, or omit. |
Fasteners | Manufacturer's standard. |
Perimeter seals | Manufacturer's standard. |
System accessories | Manufacturer guidanceConsult manufacturer for options and insert requirements, or omit. Note that Janisol 2 fire doors are to be specified separately. |
Face width | 50 mm. Guidance for specification option: Minimum. |
Thermal transmittance (U-Value) | Manufacturer guidanceInsert requirements or consult manufacturer for values. Uf value of frame: ≥ 1.4 W/m²K. |
Acoustic performance rating | Manufacturer guidanceInsert requirements; maximum sound reduction index Rw: 47 dB(A). |
Burglar resistance | Manufacturer guidanceConsult manufacturer for options and insert requirements, or omit. |
Air permeability | Class AE. |
Watertightness | Class RE 1200. |
Resistance to wind load | 2.0/ 3.0 kN/m². |
Impact resistance | Class 5. |
Fire resistance | Manufacturer guidanceConsult manufacturer for options and insert requirements. The system is designed for vertical facades in all tested fire resistance classes for internal and external use (E30/ E60/ E90, EI30/ EI60/ EI90), and approved in combination with Janisol 2 fire doors for internal use (doors specified separately). |
Standards | To DIN 4102, EN 13501-2, DIN EN 13830. |
Label | Schueco ‘IoF’ ID tag with QR code. Guidance for specification option: Internet of facades (IoF) ID tag with unique QR code linked to the product data, ongoing maintenance instructions and installation records. |
Country of material origin | United Kingdom |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 23 % |