Glidevale Protect iPSV Kit 10
Application

Ceiling extract, flat ducting, house ventilation system for ground floor (kitchen, utility and other ‘wet’ rooms).

Description

The Glidevale iPSV® intelligent passive stack ventilation system provides a low maintenance, no-energy alternative to mechanical ventilation. Glidevale iPSV is controlled by ‘intelligent’ air inlets and extracts. These respond automatically to changes in relative humidity, thereby modulating the ventilation rate in each room to meet the varying need. Ventilation levels are matched to demand.


Features and benefits:

  • Demand control for comfort.
  • Fully automatic without power - no user interaction.
  • Humidity-sensitive.
  • Whole-house ventilation.
  • Energy efficient.
  • Combat condensation and mould.
  • Continuous extraction.
  • Automatic boost effect.
  • Suitable for disabled and older people.
  • Meets building requirements.
  • Simple installation.
  • Minimal maintenance/lifetime cost savings.
  • Independently certified: BBA Certificate 18/5523.

General information

Color

White

Material

Plastic

Metal

Speed clamps.

Shape

Rectangular

Flat channel ducting.

Circular

Flexible insulated ducting.

Size

204 x 60mm

Square ducting.

∅125 mm

Round ducting.

Uniclass 2015

Pr_30_59_96_93 Ventilation gratingsPrimary
Ss_65_40_33_56 Natural ventilation systems

CAWS

F30/175 Cavity ventilators

Specification data - Ventilation gratings Enhanced data

Apertures

Circular ducting.

Round insulated ducting for cold loft space.

Work sizes

204 x 60 mm.

Flat channel ducting, 1500 mm length.

∅125 mm.

Round insulated ducting, 4000 mm length.

Material

Plastics.

Colour

White.

Accessories

TVES5dB Trickle Vents.

Fresh 99H Wall Ventilators.

Execution

Installing air bricks, gratings and ventilators in walling.

Square channel ducting designed to be installed within the stud walls of the floors above. Insulated flexible ducting designed to reach the ridge through the cold roof space.

Terminal covers

PRT25 ridge terminal.

For clay ridges - half round ridge terminal.

PRT15 ridge terminal.

For concrete ridges - half round ridge terminal.

PRT35 ridge terminal.

For concrete ridges - segmental ridge terminal.

PRT45 ridge terminal.

For concrete ridges - angle ridge terminal.

PRT46 ridge terminal.

For concrete ridges - angle ridge terminal.

Show more

Third-party certification

British Board of Agrément Certificate,18/5523 / Regulations technical handbook Domestic section 3 (Scotland) / Building regulations approved document F (England and Wales) / Building regulations Technical booklet K (Northern Ireland) / Building regulations Technical Guidance documents Part F (Republic of Ireland).