NBS Source
I'm a manufacturer

Description

One layer of Gyproc ThermaLine PIR 63mm on Gyproc Sealant (3mm nominal cavity) on existing plastered walls, level brick, block or fair faced concrete.

General information

Finish

-

Manufacturer guidance

The system should be finished using either one of our Thistle or ThistlePro plasters, or Gyproc jointing products. See the product range guides on the British Gypsum website for more information.

Material

Gypsum

Metal

Plasterboard

Steel

Uniclass

Ss_25_25_45_35 Gypsum board wall lining systemsPrimary

CAWS

K10/45 Wall lining system (adhesive)

K10/185 Wall lining system (adhesive)

Product range

Wall linings / DriLyner Dab

Specification data - Gypsum board wall lining systems

Support

Fixing method: Gyproc Sealant.

Linings

Board side 1, Layer 1: Gyproc ThermaLine PIR 63mm.

Fasteners

Secondary fixing: British Gypsum Nailable Plugs 100mm.

Finish

The system should be finished using either one of our Thistle or ThistlePro plasters, or Gyproc jointing products. See the product range guides on the British Gypsum website for more information.

System accessories

Sealant: Gyproc Sealant.
Parge coat: Gyproc SoundCoat Plus.

Execution

Please review details on the British Gypsum website at: https://www.british-gypsum.com/Specification/White-Book-Specification-Selector/wall-linings/DriLyner-Dab/RF-PIR-C-EN#details

Strength grade

Not Stated

Background

Background: Existing plastered walls or level brick, block or fair-faced concrete