Verified by manufacturer over a year ago
Solvent-free MMA car park deck coating system.
Suitable for use over exposed decks of multi-storey car parks and the refurbishment of existing car parks and on new construction projects.
IMPORTANT: All specification information must be checked against the individual site requirements. Flowcrete advises that specifications are confirmed with their technical experts.
A solvent-free methyl methacrylate car park deck coating system which provides a crack bridging, waterproof wearing surface and enables fast track applications whilst also offering slip resistance properties.
Features and benefits:
Color | Blue Green Grey Purple Red |
Finish | Satin Matt |
Material | Methyl methacrylate Guidance for specification option: Methyl methacrylate coating. |
Warranty description | Ten year |
Uniclass | |
CAWS | M12/10 Resin flooring M12/110 Resin flooring |
Substrate | |
Preparation | Concrete or screed substrate should be a minimum of 25 N/mm², free from laitance, dust and other contamination and should be dry to 95% RH as per BS 8204. |
Resin flooring | Methyl methacrylate coating. |
Adhesion | >1.5 N/mm². |
Certification | CE Marked. |
Chemical resistance | Protects against diesel, antifreeze, hydraulic fluids, chlorides and battery acids. |
Chloride ion resistance | No penetration after 28 days. |
Colour options | Dark Grey. Forest Green. Mid Grey. Tile Red. Traffic Blue. |
Crack bridging | To UNE-EN 1062-7:2004: Class A3 at -10°C; no cracks at -20°C. |
Cure time | Full traffic and chemical cure within three hours. |
Impact resistance | Class II: ≥10 Nm. |
Retroflectivity | Not required. Required. Guidance for specification option: By request; consult manufacturer for details and insert requirements. |
Slip resistance | To UNE-EN 13036-4:2003, Class III (>55 units wet). Guidance for specification option: (outside). |
Temperature resistance | Softens over 70°C and hardens on cooling. |
Thickness range | 4–5 mm. |
Water permeability | To UNE-EN 1062-3:2008, < 0.1 kg/m²/h. |
Weathering resistance | To UNE-EN 1062-11:2003 4.2 (2000 h), no defects. |
NBS BIM Object Standard
This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.
Find out more about the NBS BIM Object Standard.
Platform | Compatible | Version |
---|---|---|
- | 3 | |
- | 2 |
Deckshield ED (Exposed Deck System)
Deckshield ID (Intermediate Deck System) - Polyurethane Car Park Deck Coating
Deckshield Rapide ID System - MMA Intermediate Car Park Deck Coating
Deckshield Rapide SH
Flowchem VE GL System
Flowchem VE HD System
Flowchem VE RC System
Flowchem VE SC System
Flowchem VE SL System
Flowcoat EPN