Underfloor heating (UFH) system for use between timber joists, pipes stapled to batten-supported insulation and covered with 25 mm of dry screed mix, to be in contact with the floor deck.
Underfloor heating (UFH) system for use between timber joists, in new builds and renovation.
Underfloor heating (UFH) system for use between timber joists.
Battens are fixed to the side of the joists with a minimum of 50 mm insulation above leaving a gap of 25 mm.
The pipe is stapled to the insulation then covered with 25 mm of dry screed mix, eliminating any air gaps in between the dry screed mix and underneath the structural floor deck.
Features and benefits:
*Heat output at a flow water temperature of 45°, based on a tog rating of 1 with a room temperature of 21°. Consult manufacturer's literature for full details.
Color | White |
Material | Polyethylene |
Shape | Circle |
Length | 100000 mm |
Width | 16 mm |
Height | 16 mm |
Warranty description | Two year Guidance for specification option: Electrical and mechanical products. 50 year Guidance for specification option: Pipes. Manufacturer guidanceConsult manufacturer for full details. |
Uniclass | |
CAWS | T90/475 Underfloor heating systems T90/475 Underfloor heating systems |
System performance | Guidance for specification option: Insert requirements. |
Heat source | Low-temperature hot water heating system.Guidance for specification option: Specify details separately. |
Pumps | Beneath Heat underfloor heating pump pack.Beneath Heat single area pump pack.Manufacturer guidanceConsult manufacturer for details. |
Pipework | |
Distribution | Guidance for specification option: Insert requirements. |
Underfloor | 16 mm PERT pipes and fittings.16 mm MLCP pipes and fittings.Manufacturer guidanceInstallation tools available, including pipe decoilers, pipe cutters and pipe calibrators. |
Jointing materials | Guidance for specification option: Insert requirements. |
Insulation | Insulation panels, laid between joists.Guidance for specification option: Consult manufacturer's literature for installation details. Manufacturer guidanceConsult manufacturer for details. |
Pipe supports | 40 mm pipe staples at 150 mm centres with dry screed mix (3:1 sand/cement).60 mm pipe staples at 150 mm centres with dry screed mix (3:1 sand/cement).40 mm pipe staples at 200 mm centres with dry screed mix (3:1 sand/cement).60 mm pipe staples at 200 mm centres with dry screed mix (3:1 sand/cement).Manufacturer guidance
|
Valves | Guidance for specification option: Consult manufacturer for options and insert requirements. Options include manifolds, blend valves, heat pump valves and return elbows. |
Water treatment | Guidance for specification option: Consult manufacturer for options and insert requirements or omit. |
Accessories | 230 V Saswell dial thermostat.Guidance for specification option: Consult manufacturer for options and insert requirements. 230 V Saswell programable thermostat.230 V Saswell WiFi thermostat.Wireless Saswell programable thermostat.Wireless Saswell WiFi thermostat.Saswell WiFi gateway |
Controls | |
Controllers | Saswell 230 V two wire actuator.230 V wiring centre.230 V wireless wiring centre. |
Control valves | Saswell two-port motorised valve. |
Sensors | Not required.Saswell floor/ air sensor.Single area pump pack adaptors.Guidance for specification option: Not for use with single area pump pack. |
Floor components | Structural floor deck.Guidance for specification option: Insert details. Specify separately if required. |
Floor covering | Guidance for specification option: Insert details. Specify separately if required. |
Contains Red List materials | No |
Country of material origin | Poland |
Country of product manufacture | Poland |
Recyclability | 100 |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 100 % |