NBS Source
I'm a manufacturer
 Rf-Technologies

Rf-Technologies

OPEN TO INNOVATION, CLOSED TO FIRE

+44 7939316006 Website

Sort by:

Showing 1-15 of 15

Sponsored
ZENiX / ONE-X - Smoke & Fire Protection Control System

ZENiX / ONE-X - Smoke & Fire Protection Control System

Verified 4 months ago

Rf-Technologies

Unique, Bus-based Smoke & Fire Protection Control System, including Panels, Actuators, (integrated) Field Modules and bringing very substantial advantages to end customers, designers and installers.
Sponsored
KAMOUFLAGE AP - All Purpose, Architectural SCD - Smoke Control Damper

KAMOUFLAGE AP - All Purpose, Architectural SCD - Smoke Control Damper

Verified 5 months ago

Rf-Technologies

1366_10 April 2024 - "dw", duct AND wall certified, automatic (AOV) rectangular EIS smoke control damper (SCD) - up to 120 minutes performance.
+2
Sponsored
CR60  - Circular EIS Fire Damper (max Ø 315mm) - Fire Damper

CR60 - Circular EIS Fire Damper (max Ø 315mm) - Fire Damper

Verified 6 months ago

Rf-Technologies

Circular EIS fire damper with a fire resistance of 30, 60 or 90 minutes depending on the installation type, both for motorized and non-motorized applications. (previously known as FD and FSD / MFSD)
+2
Sponsored
CR60-1S - "ZERO liabilities" - EIS Circular Fire Damper (max Ø 315mm) - Fire Damper

CR60-1S - "ZERO liabilities" - EIS Circular Fire Damper (max Ø 315mm) - Fire Damper

Verified 5 months ago

Rf-Technologies

Circular EIS fire damper with a fire resistance of 30, 60 or 90 minutes depending on the installation type, both for motorized and non-motorized applications. (previously known as FD and FSD / MFSD)
+2
Sponsored
CU-LT - Rectangular EIS Fire Damper (max W800 x H600 mm) - Fire Damper

CU-LT - Rectangular EIS Fire Damper (max W800 x H600 mm) - Fire Damper

Verified 6 months ago

Rf-Technologies

Rectangular EIS fire damper with a fire resistance of 30, 60, 90 or 120 minutes depending on the installation type, for motorized and non-motorized applications. (previously known as FD or FSD / MFSD)
+2
Sponsored
Markage MB - Smoke Control Damper - Multi-blade - Rectangular Smoke Control Damper

Markage MB - Smoke Control Damper - Multi-blade - Rectangular Smoke Control Damper

Verified 6 months ago

Rf-Technologies

"1366-10 MA (Manual Activation) certified" smoke control damper with a fire resistance up to 120 minutes for multi-compartment applications. Up to W1200 x H2400 mm. With high nett passage performance.
+4
Sponsored
CU2 -  Rectangular EIS Fire Damper (max W1500 x H1000 mm) - Fire Damper

CU2 - Rectangular EIS Fire Damper (max W1500 x H1000 mm) - Fire Damper

Verified 6 months ago

Rf-Technologies

Rectangular EIS fire damper for duct sizes up to W1500 x H1000 mm, with a fire resistance up to 120 minutes, for motorized and non-motorized applications. (previously known as FD or FSD / MFSD)
+5
Sponsored
CU2/B - Large Rectangular EIS Fire Damper  - Maximum Four Individual Fire Dampers

CU2/B - Large Rectangular EIS Fire Damper - Maximum Four Individual Fire Dampers

Verified 6 months ago

Rf-Technologies

Rectangular EIS fire damper assembly for large duct sizes up to W3050 x H1650 mm, with a fire resistance up to 120 minutes, both for motorized and non-motorized applications.
+6
Sponsored
KAMOUFLAGE MP -  Multi Purpose, Architectural SCD - Smoke Control Damper

KAMOUFLAGE MP - Multi Purpose, Architectural SCD - Smoke Control Damper

Verified 6 months ago

Rf-Technologies

Automatic (AOV) Rectangular EIS smoke control damper (SCD) - fire resistance up to 120 minutes. Can be easily integrated in many smoke control systems thanks to its aesthetic finishing possibilities.
+2
Sponsored
AVANTAGE MP -  Multi Purpose SCD with Grille - Motorized Smoke Control Shutter

AVANTAGE MP - Multi Purpose SCD with Grille - Motorized Smoke Control Shutter

Verified 6 months ago

Rf-Technologies

Automatic (AOV) Rectangular EIS smoke control damper (SCD) -fire resistance up to 120 minutes- AA, Multi, C10.000, shaft installation c/w. grille, including aesthetical, architectural design option
+2
Sponsored
CR120  - Circular EIS Fire Damper (max Ø 315mm) - Fire Damper

CR120 - Circular EIS Fire Damper (max Ø 315mm) - Fire Damper

Verified 1 month ago

Rf-Technologies

Circular EIS fire damper with a fire resistance of 60, 90 or 120 minutes depending on the installation type, both for motorized and non-motorized applications. (previously known as FD and FSD / MFSD)
+4
Sponsored
CR2 - Circular EIS Fire Damper (max Ø 630mm) - Fire Damper

CR2 - Circular EIS Fire Damper (max Ø 630mm) - Fire Damper

Verified 6 months ago

Rf-Technologies

Circular EIS fire damper with a fire resistance of 60, 90 or 120 minutes depending on the installation type, both for motorized and non-motorized applications. (previously known as FD and FSD / MFSD)
+2
Sponsored
CU4 -  Rectangular EIS 4Hours Fire Damper - Fire Damper

CU4 - Rectangular EIS 4Hours Fire Damper - Fire Damper

Verified 6 months ago

Rf-Technologies

Rectangular EIS fire damper for duct sizes up to W1200 x H800 mm, UKCA/CE certified, with a fire resistance up to 240 minutes in rigid walls, both for motorized and non-motorized applications.
+2
Sponsored
VU120 - Smoke Control Damper - Single-blade - Rectangular Smoke Control Damper

VU120 - Smoke Control Damper - Single-blade - Rectangular Smoke Control Damper

Verified 4 months ago

Rf-Technologies

"BS EN 1366-10 AA certified" smoke control damper, with a fire resistance (EIS) upto 120 minutes. For installation in vertical and horizontal smoke extraction ducts and shafts.
+2
Sponsored
VUW120 - Smoke Control Damper - Wall certified - Rectangular Smoke Control Damper

VUW120 - Smoke Control Damper - Wall certified - Rectangular Smoke Control Damper

Verified 4 months ago

Rf-Technologies

"BS EN 1366-10 AA certified" smoke control damper, with a fire resistance (EIS) upto 120 minutes. For installation in walls (fire compartment boundaries).

Showing 1-15 of 15