Verified by manufacturer 2 months ago
BM Trada
Certificate type
FSC
Certificate type
Lead lined severe duty doorset, designed for high use within hospital, medical and healthcare environment
Primarily used in health environments to shield X-rays.
Highly functional doorsets for use in higher performing situations where X-ray shielding is necessary. The doors can be installed in a number of configurations delivering progressive levels of shielding and fire performances.
Features and benefits:
Color | Other Beige Black Blue Brown |
Finish | Veneered Laminated Primed Painted Other Guidance for specification option: PVC (postformed) and PVC. |
Material | Wood Lead Acrovyn® Laminate Other |
Shape | Rectangle |
Length | Bespoke Guidance for specification option: Single door - Clear Opening Width: up to 2077mm. Clear Opening High: up to 3265mm Double door - Clear Opening Width: up to 2077mm. Clear Opening High: up to 3165mm |
Width | Bespoke Guidance for specification option: Single door - Clear Opening Width: up to 2077mm. Clear Opening High: up to 3265mm Double door - Clear Opening Width: up to 2077mm. Clear Opening High: up to 3165mm |
Height | Bespoke Guidance for specification option: Single door - Clear Opening Width: up to 2077mm. Clear Opening High: up to 3265mm Double door - Clear Opening Width: up to 2077mm. Clear Opening High: up to 3165mm |
Warranty description | Ten year |
Uniclass | |
CAWS | L20/410 Wood doorsets L20/55 Doorsets |
Third-party certification | FSC Compliant; Q-Mark compliant; ISO: 9001:2015. |
Standard | To BS 476 Part 22:1987; BS EN 1634-1. |
Wood in joinery standard | To BS EN 942 and BS EN 1186. |
Configuration | Single-leaf, single-action, latched.Single-leaf, single-action, unlached.Double-leaf, single-action, latched.Double-leaf, single-action, unlached. |
Doorset size | Bespoke.Guidance for specification option: Insert requirements. Single Door
Double Door
|
Performance | |
Fire resistance | |
Integrity | Non-fire rated.EI30S.EI60S.E 30 minutes.E 60 minutes.EI60.EI30. |
Smoke leakage | To BS EN 1634-3:2004 and BS476 Part 31.1. |
Acoustic performance | Unrated. |
Strength and durability | To BS EN 1192, Class 4.Guidance for specification option: Severe duty ratings DD171/ EN 1192. |
Thermal | 2.00 W/m²K. |
Frame | |
Material | Hardwood. |
Species | Oak.Sapele.Beech.Ash.Others.Guidance for specification option: Consult manufacturer for details and insert requirements. |
Appearance class | J10. |
Threshold | Low profile aluminium.Low profile hardwood. |
Perimeter seals or inserts | Fire and smoke seal. |
Finish | Primed.Full paint finish.PVC wrapped (postform).Veneer.Laminate. |
Colour | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
External | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Internal | As External.Other.Guidance for specification option: Consult manufacturer for details and insert requirements. |
Installation fasteners | Stainless steel screws.2000 hr + zinc plated screws.Fischer through fittings.Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Door leaf | |
Thickness | 54 mm.Guidance for specification option: As BS EN 942 timber in joinery requirement. |
Core | Solid core.Guidance for specification option: Solid timber core. |
Panel details | Manufacturer guidanceConsult manufacturer for details and insert requirements or omit. |
Facings | Primed.Full paint finish.PVC wrapped (postform).Veneer.Laminate.PVC. |
Species | Oak.Sapele.Beech.Ash.Walnut.Maple.Others.Guidance for specification option: Consult manufacturer for details and insert requirements. |
Cut | Crown cut veneer.Quarter cut veneer.Rotary cut veneer.Rift cut veneer. |
Lippings | 5–18 mm Sapele.5–18 mm Oak.5–18 mm Walnut.5–18 mm Beech.5–18 mm Maple.Other.Guidance for specification option: 5–18 mm. Consult manufacturer for details and insert requirements. Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Perimeter seals | Fire and smoke. |
Finish | Primed.Full paint finish.PVC wrapped (postform).Veneer.Laminate.PVC. |
Colour | |
External | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Internal | As External.Other.Guidance for specification option: Consult manufacturer for details and insert requirements. |
Glazing | |
Type | Glazed.Glazed - Lead glass.Guidance for specification option: Consult manufacturer for details and insert requirements. Unglazed. |
Manifestation | Manufacturer guidanceConsult manufacturer and insert requirements. |
Beading | |
Type | Internal.External. |
Material | Hardwood.Softwood. |
Fixing | Paslode nails. |
Door accessories | Glazing - laser protection.Lead lined astragals.Guidance for specification option: Consult manufacturer for details. Locks and cylinders.intumescent wraps.Fire signage.Door closers.Hinges.Kickplates.Edge Protectors.Fire and Smoke Seals.Threshold Seals.Face fitted EMHO.Other.Guidance for specification option: Consult manufacturer for details and insert requirements. |
Planted stops | |
Wood species | Oak.Sapele.Beech.Ash.Maple.Walnut.Others.Guidance for specification option: Consult manufacturer for details and insert requirements. |
Appearance class | J10. |
Finish | Primed.Full paint finish.PVC wrapped (postform).Veneer.Laminate. |
Colour | Manufacturer guidanceConsult manufacturer and insert requirements. |
Hardware | Latches and locksSingle axis hingesControlled door closing devicesElectrically Powered hold open devicesDoor co-ordinatorsEmergency exit hardwarePanic exit hardware |
Architraves | |
Material | Oak.Sapele.Beech.Ash.Black Walnut.Maple.Others.Guidance for specification option: Consult manufacturer for details and insert requirements. |
Wood appearance class | To BS EN 942, Class J10. |
Finish | Primed.Full paint finish.PVC wrapped (postform).Veneer.Laminate. |
Colour | |
External | Manufacturer guidanceConsult manufacturer for details and insert requirements. |
Internal | As External.Other.Guidance for specification option: Consult manufacturer for details and insert requirements. |
Accessories | Not required.Single axis butt hinge.Lift off hinge.Ball bearing hinge.Concealed bearing hinge.Cam action electromagnetic closers (test standard EN 1155).Overhead face fixed closers.Overhead concealed closers.Jamb mounted closers.Concealed heavy duty slide arm.Pull handles.Lever handles.Knobs.Kickplates.Single point lock.Sashlock.Mortice lock.Tubular latch.Tubular mortice.Lever mortice.Multi-point lock.Manufacturer guidanceConsult manufacturer for details and insert requirements or omit. |
X-ray protection | Code 3. Code 4. Code 5. Code 6. Code 7. |
Contains Red List materials | Yes |
Country of material origin | Europe |
Country of product manufacture | United Kingdom |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 0.25 kg CO₂ eq/kg Self declared |
Recyclability | 100% |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 60 % |