Verified by manufacturer 4 days ago
Multi-layer thermoplastic volatile organic compound (VOC) and gas barrier.
Used in all types of buildings to prevent the ingress of harmful levels of volatile organic compounds (VOCs), methane, carbon dioxide and radon.
The barrier can be positioned above or below reinforced cast in situ concrete floor slabs e.g. ground bearing, suspended or raft, or above precast suspended segmental subfloors, e.g. beam and block floor.
The barrier can also be used as a high performance radon membrane and/ or damp proof membrane.
Where protection against VOCs or hydrocarbon contamination is required, the barrier system should be applied with welded joints.
For site or zone characteristic gas situations of CS4 and above, contact Visqueen Technical Services.
The barrier is not intended for use where there is a risk of hydrostatic pressure.
A co-extruded, multi-layer thermoplastic volatile organic compound (VOC) and gas barrier, 0.6 mm thick (600 micron). The membrane is transparent with a blue tint and supplied 2 x 50 m in a single wound roll.
Features and benefits:
Approvals and standards:
Should be installed in accordance with the manufacturers recommendations.
Color | Clear Blue |
Finish | Other |
Material | Plastic Guidance for specification option: Thermoplastic. |
Shape | Rectangle |
Length | 50000 mm |
Width | 2000 mm |
Height | 0.6 mm |
Warranty description | Manufacturer guidanceSee manufacturer's insurance document for warranty details. Consult manufacturer for further information. |
Uniclass | |
CAWS | J40/297 Waterproofing/ damp-proofing/ gas-retardant membrane J40/140 Loose-laid plastics or rubber sheet gas-retardant membranes J40/35 Loose-laid plastics or rubber gas-retardant membranes |
Classification data | |
Product reference | Visqueen Ultimate Gas Barrier NF-600. |
Material | Thermoplastic. |
Purpose | Gas retardance. |
Standard | To BS EN 13967. |
Third-party certification | BDA Agrément certificate. Guidance for specification option: Certificate BAB-24-339-P-A-UK. |
Performance characteristics | |
Tensile strength (minimum) | Machine direction: 28.7 N/mm². Cross direction: 24.8 N/mm². Manufacturer guidanceTo BS EN 12311-2. |
Tear resistance | Machine direction: 365 N. Cross direction: 330 N. Guidance for specification option: Consult manufacturer's literature for trouser and angle method data. Manufacturer guidanceTo BS EN 12310-1. |
Elongation to break | Machine direction: 901%. Cross direction: 814%. Manufacturer guidanceTo BS EN 12311-2. |
Resistant to underground gases | Carbon dioxide. Methane. Radon. |
Water vapour resistance (minimum) | 5826 MN·s/g. Manufacturer guidanceTo BS EN 1931. |
Form | Multi-layer. |
Physical properties | |
Colour | Blue/ clear. |
Weight (minimum) | 570 g/m². |
Dimensions | |
Thickness (minimum) | 600 µm. |
Width (minimum) | 2 m. |
Roll length (minimum) | 50 m. |
Joint strength | Taped joint: 254 N/50 mm. Welded joint: 401 N/50 mm. Manufacturer guidanceTo BS EN 12317-2. |
Watertightness | Pass. Guidance for specification option: Watertightness at 2 kPa for 24 hours - BS EN 1928. Watertightness at 2 kPa for 24 hours after ageing - BS EN 1296. Watertightness at 2 kPa for 24 hours after alkali environment - BS EN 1847. |
Impact resistance | 350 mm. Manufacturer guidanceTo BS EN 12691. |
Water vapour permeability | 0.06 g/m²/d. Manufacturer guidanceTo BS EN 1931. |
Resistance to static loading - 20kg load | 20 kg. Manufacturer guidanceTo BS EN 12730. |
Application temperature | Recommended should not be used below 5°C. |
Methane transmission rate | 13.2 ml/m²/day/atm. Manufacturer guidanceTo BS ISO 15105-1. |
Carbon dioxide transmission rate | 28.7 ml/m²/day/atm. Manufacturer guidanceTo BS ISO 15105-1. |
Radon transmittance | 1.3 +/- 0.2 x 10-13 m²/s. Manufacturer guidanceTo PD ISO/TS 11665-13. |
Accessories | Not required. VisqueenPro Double Sided Jointing Tape, 50 mm x 10 m. Visqueen TreadGUARD 1500, 1 x 2 m. Visqueen TreadGUARD 300, 2 x 75 m. Visqueen NF-Detailing Strip, 300 mm x 10 m. Visqueen NF-Detailing Strip, 500 mm x 10 m. Visqueen NF-150 Lap Tape, 150 mm x 10 m. |
Material | Plastic Guidance for specification option: Thermoplastic. |
Visqueen Class B FR Vapour Check - Air Vapour Control Layer membrane
Visqueen DPM
Visqueen Fully Bonded Vapour Barrier - Composite air vapour control layer
Visqueen Gas Barrier
Visqueen Gas Barrier NF-400 - Gas, Radon and Damp Proof Membrane
Visqueen High Performance (HP) Vapour Barrier - Composite air vapour control layer
Visqueen High Performance DPM
Visqueen High Performance Urban Drainage Geomembrane (HP UDG)
Visqueen Low Permeability Gas Membrane
Visqueen NF-Vapour Barrier - Air Vapour Control Layer Membrane