Verified by manufacturer 4 months ago
DoP
Certificate type
A fire resistant air and vapour control layer membrane.
Visqueen Class B FR Vapour Check is used in buildings where an air and vapour control layer (AVCL) is required that achieves a reaction to fire classification B-s1, d0 to BS EN 13501-1:2018. The membrane is used to reduce the risk of interstitial condensation occurring within the structure as well as improving the airtightness of the building.
The membrane restricts the passage of warm, moist air within the building from permeating into the floor, wall or roof structure and is designed to be installed on the warm side of the structure.
For conformity with the reaction to fire classification, usage of Visqueen FR Double Sided Vapour Tape must not exceed 11% of the area of the Visqueen Class B FR Vapour Check.
For conformity with the reaction to fire classification, usage of Visqueen FR Single Sided Vapour Tape must not exceed 11% of the area of the Visqueen Class B FR Vapour Check.
Visqueen Class B FR Vapour Check is an orange tinted, semi transparent, modified fire resistant polyethylene AVCL (air and vapour control layer).
The product is 0.125 mm thick (500 gauge). The membrane is supplied in centre-folded rolls 2.45 x 50 m and multi-folded rolls 4 x 50 m.
Features and benefits:
Approvals and standards:
Color | Orange |
Finish | Smooth |
Material | Polyethylene |
Shape | Rectangle |
Length | 50000 mm |
Width | 2450 mm 4000 mm |
Warranty description | Guidance for specification option: See manufacturer's insurance document for warranty details. Consult manufacturer for further information. |
Uniclass | |
CAWS | H30/261 Air and vapour control membrane H30/30 Air and vapour control membrane H31/261 Air and vapour control membrane H31/45 Air and vapour control membrane H92/780 Air and vapour control layer J21/10 Warm deck roof coating J21/395 Air and vapour control layer J31/30 Laying air and vapour control layer J31/330 Air and vapour control layer J41/10 Reinforced bitumen membrane warm deck roof covering J41/395 Air and vapour control layer J42/10 Warm deck roof covering J42/395 Air and vapour control layer K11/115 Battened plywood floating floor K11/125 Battened particleboard floating floor K11/135 Battened oriented strand board floating floor K11/145 Battened cement-bonded particleboard floating floor K11/20 Battened particleboard floating floor K11/215 Plywood floating floor K11/225 Particleboard floating floor K11/235 Oriented strand board floating floor K11/245 Cement bonded particleboard floating floor K11/25 Particleboard floating floor K11/795 Wall lining on metal framing K21/10 Wood laminate flooring K21/110 Wood flooring K21/111 Wood floating floor K21/115 Wood laminate flooring K21/120 Battened wood flooring K21/130 Battened wood floating floor K21/140 Battened wood laminate flooring K21/145 Composite laminate flooring K21/146 Laminate flooring K21/20 Composite laminated flooring P10/310 Air and vapour control layer P10/60 Air and vapour control layer |
Material | Polyethylene. |
Purpose | Vapour control layer. |
Standard | UKCA/ UKNI Mark EN 13984. |
Performance characteristics | |
Tensile strength (minimum) | 15 N/mm². |
Elongation to break | 400%. |
Water vapour resistance (minimum) | 266 MN·s/g. |
Fire performance | B-s1, d0 to BS EN 13501-1. |
Physical properties | |
Colour | Orange. |
Weight (minimum) | 128 g/m². |
Dimensions | |
Thickness (minimum) | 0.125 mm. |
Width (minimum) | 2.45 m.4 m. |
Roll length (minimum) | 50 m. |
Accessories | Visqueen FR Double Sided Vapour Tape. Visqueen FR Single Sided Vapour Tape. |
Joint strength | 50 N. |
Water vapour resistance | 341 MNs/g. |
Water vapour transmission | 0.481 g/m²/d. |
Air leakage | 0 m³/h/m² at ±100 Pa. |
Impact resistance | 200 mm. |
Country of material origin | United Kingdom |
Country of product manufacture | United Kingdom |
Material | Polyethylene |