A fire resistant air and vapour control layer membrane.

Jump to:
+44 (0) 333 202 6800 Website

Application

Visqueen Class B FR Vapour Check is used in buildings where an air and vapour control layer (AVCL) is required that achieves a reaction to fire classification B-s1, d0 to BS EN 13501-1:2018. The membrane is used to reduce the risk of interstitial condensation occurring within the structure as well as improving the airtightness of the building.


The membrane restricts the passage of warm, moist air within the building from permeating into the floor, wall or roof structure and is designed to be installed on the warm side of the structure.


For conformity with the reaction to fire classification, usage of Visqueen FR Double Sided Vapour Tape must not exceed 11% of the area of the Visqueen Class B FR Vapour Check.


For conformity with the reaction to fire classification, usage of Visqueen FR Single Sided Vapour Tape must not exceed 11% of the area of the Visqueen Class B FR Vapour Check.

Description

Visqueen Class B FR Vapour Check is an orange tinted, semi transparent, modified fire resistant polyethylene AVCL (air and vapour control layer).


The product is 0.125 mm thick (500 gauge). The membrane is supplied in centre-folded rolls 2.45 x 50 m and multi-folded rolls 4 x 50 m.


Features and benefits:

  • Fire Classification B-s1, d0
  • Suitable for all building heights including residential over 18m high.
  • CE UKCA Mark to EN 13984:2013
  • Achieves Building Regulation and warranty provider requirements.
  • Third party tested to EN 13501-1:2018 - fully tested AVCL system (including tapes) for fire resistance.
  • Convenient 2.45m wide roll for wall applications - rapid installation reducing the need for horizontal lap joints.
  • Versatile application used within floor, wall and roof constructions - provides air tightness, water vapour resistance and reduces the risk of condensation.
  • Excellent puncture and tensile strength characteristics - robust for on-site handling and installation.


Approvals and standards:

  • System achieves a reaction to fire classification B-s1, d0 to BS EN 13501-1:2018.
  • Air leakage to BS EN 1026:2016.
  • CE UKCA Mark EN 13984:2013.
  • Quality Management System ISO 9001:2015.
  • Occupational Health and Safety System ISO 45001:2018.
  • Environmental Management System ISO 14001:2015.

General information

Color

Orange

Finish

Smooth

Material

Polyethylene

Shape

Rectangle

Length

50000 mm

Width

2450 mm

4000 mm

Warranty description

Guidance for specification option:

See manufacturer's insurance document for warranty details. Consult manufacturer for further information.

Uniclass

Pr_25_57_65_60 Plastics sheetsPrimary

CAWS

H30/261 Air and vapour control membrane

H30/30 Air and vapour control membrane

H31/261 Air and vapour control membrane

H31/45 Air and vapour control membrane

H92/780 Air and vapour control layer

J21/10 Warm deck roof coating

J21/395 Air and vapour control layer

J31/30 Laying air and vapour control layer

J31/330 Air and vapour control layer

J41/10 Reinforced bitumen membrane warm deck roof covering

J41/395 Air and vapour control layer

J42/10 Warm deck roof covering

J42/395 Air and vapour control layer

K11/115 Battened plywood floating floor

K11/125 Battened particleboard floating floor

K11/135 Battened oriented strand board floating floor

K11/145 Battened cement-bonded particleboard floating floor

K11/20 Battened particleboard floating floor

K11/215 Plywood floating floor

K11/225 Particleboard floating floor

K11/235 Oriented strand board floating floor

K11/245 Cement bonded particleboard floating floor

K11/25 Particleboard floating floor

K11/795 Wall lining on metal framing

K21/10 Wood laminate flooring

K21/110 Wood flooring

K21/111 Wood floating floor

K21/115 Wood laminate flooring

K21/120 Battened wood flooring

K21/130 Battened wood floating floor

K21/140 Battened wood laminate flooring

K21/145 Composite laminate flooring

K21/146 Laminate flooring

K21/20 Composite laminated flooring

P10/310 Air and vapour control layer

P10/60 Air and vapour control layer

Specification data - Plastics sheets

Material

Polyethylene.

Purpose

Vapour control layer.

Standard

UKCA/ UKNI Mark EN 13984.

Performance characteristics

-

Tensile strength (minimum)

15 N/mm².

Elongation to break

400%.

Water vapour resistance (minimum)

266 MN·s/g.

Fire performance

B-s1, d0 to BS EN 13501-1.

Physical properties

-

Colour

Orange.

Weight (minimum)

128 g/m².

Dimensions

-

Thickness (minimum)

0.125 mm.

Width (minimum)

2.45 m.

4 m.

Roll length (minimum)

50 m.

Accessories

Visqueen FR Double Sided Vapour Tape.

Visqueen FR Single Sided Vapour Tape.

Joint strength

50 N.

Water vapour resistance

341 MNs/g.

Water vapour transmission

0.481 g/m²/d.

Air leakage

0 m³/h/m² at ±100 Pa.

Impact resistance

200 mm.

Sustainability data

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Polyethylene

Third party certifications

DoP

DoP

UKCA Declaration of Performance Visqueen Class B FR Vapour Check