Verified by manufacturer 17 hours ago
Vieo Warm Wall MW5 is a warm wall system designed to use our MW5 steel liner profile as a substrate, with RocSlab insulation and our RocTubes.
Designed for use on steel framed buildings.
Suitable for a wide range of building applications, such as for use with residential, commercial and public buildings.
Vieo Warm Wall MW5 is a warm wall system designed to use our MW5 steel liner profile as a substrate, with RocSlab insulation and our RocTubes.
Features and benefits:
An aluminium sheet, fully-supported system is also available, specified separately.
Matching roof systems and cold wall systems and also available, specified separately.
| Color | Gold Grey Black Blue Red | 
| Finish | Coated Matt Textured Smooth | 
| Material | Steel Mineral wool | 
| Shape | Other Guidance for specification option: Sinusoidal. | 
| Length | Bespoke | 
| Width | Bespoke | 
| Height | Bespoke | 
| Warranty description | 25 year Guidance for specification option: A Vieo system guarantee is available for up to 25 years; consult manufacturer for details. | 
| Uniclass | |
| CAWS | H31/10 Metal H31/120 Metal profiled sheet self-supporting cladding/ roof covering | 
| Classification data | |
| System performance | Guidance for specification option: Insert requirements. Manufacturer guidanceReaction to fire to BS EN 13501-1:2018 (inc. BS EN ISO 11925-2:2020 + BS EN 13823:2020): Classification on component basis only, see individual component guidance or consult manufacturer for details. | 
| Liner sheets | |
| Material | EC 32-200-1000 Liner MW5 Deck Swaged. Manufacturer guidance0.70 mm steel as standard. | 
| Primary fasteners | Manufacturer's standard. | 
| End and side laps | Manufacturer's standard. | 
| Air and vapour control layer | |
| Material | Euroclad B VCL. Euroclad A2 VCL. | 
| Fasteners | Manufacturer's standard. | 
| Sealing | Euroclad VCL Sealing Tape. Euroclad A2 VCL Sealing Tape. | 
| Spacers | Euroclad RocBar. Manufacturer guidanceRocSlab25 insulation between bars; see Thermal insulation. | 
| Acoustic insulation | Not applicable. | 
| Thermal insulation | RocSlab 50 mm and RocSlab25. Guidance for specification option: System depth: 136.1 mm. System weight: 28.16 kg/m². U-value from calculation: NPD. RocSlab 50 mm + 50 mm and RocSlab25. Guidance for specification option: System depth: 186.1 mm. System weight: 35.22 kg/m². U-value from calculation: NPD. RocSlab 115 mm and RocSlab25. Guidance for specification option: System depth: 201.1 mm. System weight: 35.25 kg/m². U-value from calculation: 0.25 W/m²K. RocSlab 150 mm and RocSlab25. Guidance for specification option: System depth: 236.1 mm. System weight: 39.55 kg/m². U-value from calculation: 0.20 W/m²K. RocSlab 50 mm + 115 mm and RocSlab25. Guidance for specification option: System depth: 251.1 mm. System weight: 42.30 kg/m². U-value from calculation: 0.20 W/m²K. RocSlab 170 mm and RocSlab25. Guidance for specification option: System depth: 256.1 mm. System weight: 42.01 kg/m². U-value from calculation: 0.18 W/m²K. RocSlab 50 mm + 150 mm and RocSlab25. Guidance for specification option: System depth: 286.1 mm. System weight: 46.62 kg/m². U-value from calculation: 0.16 W/m²K. RocSlab 205 mm and RocSlab25. Guidance for specification option: System depth: 291.1 mm. System weight: 46.32 kg/m². U-value from calculation: 0.16 W/m²K. RocSlab 50 mm + 170 mm and RocSlab25. Guidance for specification option: System depth: 306.1 mm. System weight: 49.09 kg/m². U-value from calculation: 0.15 W/m²K. RocSlab 115 mm + 115 mm and RocSlab25. Guidance for specification option: System depth: 316.1 mm. System weight: 49.41 kg/m². U-value from calculation: 0.15 W/m²K. RocSlab 50 mm + 205 mm and RocSlab25. Guidance for specification option: System depth: 341.1 mm. System weight: 53.38 kg/m². U-value from calculation: 0.13 W/m²K. RocSlab 115 mm + 150 mm and RocSlab25. Guidance for specification option: System depth: 351.1 mm. System weight: 53.72 kg/m². U-value from calculation: 0.13 W/m²K. RocSlab 115 mm + 170 mm and RocSlab25. Guidance for specification option: System depth: 337.1 mm. System weight: 56.19 kg/m². U-value from calculation: 0.12 W/m²K. RocSlab 150 mm + 150 mm and RocSlab25. Guidance for specification option: System depth: 386.1 mm. System weight: 58.08 kg/m². U-value from calculation: 0.12 W/m²K. RocSlab 150 mm + 170 mm and RocSlab25. Guidance for specification option: System depth: 406.1 mm. System weight: 60.55 kg/m². U-value from calculation: 0.11 W/m²K. RocSlab 115 mm + 205 mm and RocSlab25. Guidance for specification option: System depth: 406.1 mm. System weight: 60.55 kg/m². U-value from calculation: 0.11 W/m²K. RocSlab 170 mm + 170 mm and RocSlab25. Guidance for specification option: System depth: 426.1 mm. System weight: 63.02 kg/m². U-value from calculation: 0.11 W/m²K. RocSlab 150 mm + 205 mm and RocSlab25. Guidance for specification option: System depth: 441.1 mm. System weight: 64.99 kg/m². U-value from calculation: 0.10 W/m²K. RocSlab 170 mm + 205 mm and RocSlab25. Guidance for specification option: System depth: 461.1 mm. System weight: 67.46 kg/m². U-value from calculation: 0.10 W/m²K. Manufacturer guidanceInsulation lambda claim - thermal: 0.036 W/m·K. 25 mm-thick RocSlab between RocBars. | 
| Cavity fire barriers | |
| Horizontal barriers | Not required for this Vieo System. If desired, specification and detailing principles should be sought from the cavity barrier supplier. Guidance for specification option: Insert further details or omit cavity barrier requirements as applicable. | 
| Vertical barriers | Not required for this Vieo System. If desired, specification and detailing principles should be sought from the cavity barrier supplier. Guidance for specification option: Insert further details or omit cavity barrier requirements as applicable. | 
| Firestops | Not required for this Vieo System. If desired, specification and detailing principles should be sought from the firestop supplier. Guidance for specification option: Insert further details or omit firestop requirements as applicable. | 
| External sheets | |
| Material | 0.70 mm steel, S220 GD + ZA255. 0.70 mm steel, S220 GD + Z275. | 
| Primary fasteners | Stainless steel fixings (Vieo sliding clips and Vieo clip fixings). Guidance for specification option: 
 | 
| End and side laps | Vieo Closures. Guidance for specification option: Consult manufacturer for details. | 
| System accessories | Euroclad Separation Tape. | 
| Colour/ Finish | Tata Steel Colorcoat Prisma®. Guidance for specification option: 
 Tata Steel Colorcoat Prisma® - Textured. Guidance for specification option: 
 Tata Steel Colorcoat HPS200 Ultra®. Guidance for specification option: 
 | 
| System depth | Manufacturer's standard. Guidance for specification option: Dependent on U-value requirement; see Thermal insulation guidance for details. | 
| Weight | Manufacturer's standard. Guidance for specification option: Dependent on U-value requirement; see Thermal insulation guidance for details. | 
| Orientation | Horizontal. | 
| Sheet width | Cover width: 454 mm. Guidance for specification option: As standard. Can also be supplied in variable widths to give a concertina-style effect (on request). | 
| Substrate | Designed to use with Euroclad's MW5 steel liner profile. Guidance for specification option: Consult manufacturer for details. | 
| Material | Steel Mineral wool |