Verified by manufacturer today
Vieo Warm Roof MW5 is a warm roof system designed to use our MW5 steel liner profile as a substrate, with RocSlab insulation and our RocTubes.
Designed for use on steel framed buildings.
Suitable for a wide range of building applications, such as residential, commercial and public buildings.
Vieo Warm Roof MW5 is a warm roof system designed to use our MW5 steel liner profile as a substrate, with RocSlab insulation and our RocTubes.
Features and benefits:
An aluminium sheet, fully-supported system is also available, specified separately.
Matching wall systems and cold roof systems and also available, specified separately.
Color | Gold Grey Black Blue Red |
Finish | Coated Matt Textured Smooth |
Material | Steel Mineral wool |
Shape | Other Guidance for specification option: Sinusoidal. |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | 25 year Guidance for specification option: A Vieo system guarantee is available for up to 25 years; consult manufacturer for details. |
Uniclass | |
CAWS | H31/10 Metal H31/120 Metal profiled sheet self-supporting cladding/ roof covering |
Classification data | |
System performance | Guidance for specification option: Insert requirements. Manufacturer guidanceReaction to fire to BS EN 13501-1:2018 (inc. BS EN ISO 11925-2:2020 + BS EN 13823:2020): Classification on component basis only, see individual component guidance or consult manufacturer for details. |
Liner sheets | |
Material | EC 32-200-1000 Liner MW5 Deck. EC 32-200-1000 Liner MW5 Deck Swaged. Manufacturer guidance0.70 mm steel as standard. |
Primary fasteners | Manufacturer's standard. |
End and side laps | Manufacturer's standard. |
Air and vapour control layer | |
Material | Euroclad VCL. |
Fasteners | Manufacturer's standard. |
Sealing | Euroclad VCL Sealing Tape. |
Spacers | Euroclad RocBar. Manufacturer guidanceRocSlab25 insulation between bars; see Thermal insulation. |
Acoustic insulation | Not applicable. |
Thermal insulation | RocSlab 50 mm and RocSlab25. Guidance for specification option: System depth: 136.2 mm. System weight: 28.23 kg/m². U-value from calculation: NPD. RocSlab 50 mm + 50 mm and RocSlab25. Guidance for specification option: System depth: 186.2 mm. System weight: 35.30 kg/m². U-value from calculation: NPD. RocSlab 115 mm and RocSlab25. Guidance for specification option: System depth: 201.2 mm. System weight: 35.33 kg/m². U-value from calculation: 0.25 W/m²K. RocSlab 150 mm and RocSlab25. Guidance for specification option: System depth: 236.2 mm. System weight: 39.64 kg/m². U-value from calculation: 0.20 W/m²K. RocSlab 50 mm + 115 mm and RocSlab25. Guidance for specification option: System depth: 251.2 mm. System weight: 42.38 kg/m². U-value from calculation: 0.19 W/m²K. RocSlab 170 mm and RocSlab25. Guidance for specification option: System depth: 256.2 mm. System weight: 42.09 kg/m². U-value from calculation: 0.18 W/m²K. RocSlab 50 mm + 150 mm and RocSlab25. Guidance for specification option: System depth: 286.2 mm. System weight: 46.69 kg/m². U-value from calculation: 0.16 W/m²K. RocSlab 205 mm and RocSlab25. Guidance for specification option: System depth: 291.2 mm. System weight: 46.40 kg/m². U-value from calculation: 0.15 W/m²K. RocSlab 50 mm + 170 mm and RocSlab25. Guidance for specification option: System depth: 306.2 mm. System weight: 49.17 kg/m². U-value from calculation: 0.15 W/m²K. RocSlab 115 mm + 115 mm and RocSlab25. Guidance for specification option: System depth: 316.2 mm. System weight: 49.48 kg/m². U-value from calculation: 0.15 W/m²K. RocSlab 50 mm + 205 mm and RocSlab25. Guidance for specification option: System depth: 341.2 mm. System weight: 53.46 kg/m². U-value from calculation: 0.13 W/m²K. RocSlab 115 mm + 150 mm and RocSlab25. Guidance for specification option: System depth: 351.2 mm. System weight: 53.79 kg/m². U-value from calculation: 0.13 W/m²K. RocSlab 115 mm + 170 mm and RocSlab25. Guidance for specification option: System depth: 337.2 mm. System weight: 56.26 kg/m². U-value from calculation: 0.13 W/m²K. RocSlab 150 mm + 150 mm and RocSlab25. Guidance for specification option: System depth: 386.2 mm. System weight: 58.15 kg/m². U-value from calculation: 0.12 W/m²K. RocSlab 150 mm + 170 mm and RocSlab25. Guidance for specification option: System depth: 406.2 mm. System weight: 60.62 kg/m². U-value from calculation: 0.11 W/m²K. RocSlab 115 mm + 205 mm and RocSlab25. Guidance for specification option: System depth: 406.2 mm. System weight: 60.62 kg/m². U-value from calculation: 0.11 W/m²K. RocSlab 170 mm + 170 mm and RocSlab25. Guidance for specification option: System depth: 426.2 mm. System weight: 63.09 kg/m². U-value from calculation: 0.11 W/m²K. RocSlab 150 mm + 205 mm and RocSlab25. Guidance for specification option: System depth: 441.2 mm. System weight: 65.06 kg/m². U-value from calculation: 0.10 W/m²K. RocSlab 170 mm + 205 mm and RocSlab25. Guidance for specification option: System depth: 461.2 mm. System weight: 67.53 kg/m². U-value from calculation: 0.10 W/m²K. Manufacturer guidanceInsulation lambda claim - thermal: 0.036 W/m·K. 25 mm-thick RocSlab between RocBars. |
Cavity fire barriers | Not required for this Vieo System. If desired, specification and detailing principles should be sought from the cavity barrier supplier. Guidance for specification option: Insert further details or omit cavity barrier requirements as applicable. |
Firestops | Not required for this Vieo System. If desired, specification and detailing principles should be sought from the firestop supplier. Guidance for specification option: Insert further details or omit firestop requirements as applicable. |
External sheets | |
Material | 0.70 mm steel, S220 GD + ZA255. 0.70 mm steel, S220 GD + Z275. |
Primary fasteners | Stainless steel fixings (Vieo sliding clips and Vieo clip fixings). Guidance for specification option:
|
End and side laps | Vieo Closures. Guidance for specification option: For completion of detailing and ends and edges of Vieo sheets. Aluminium, Class A1 to BS EN 13501-1:2018. |
Gutters | |
Material | Guidance for specification option: Gutter detailing is part of the manufacturer's standard details for the cold roof system. These gutters could be supplied by their architectural department if desired. Consult manufacturer for options and insert requirements, or omit. |
Support | Guidance for specification option: Consult manufacturer for options and insert requirements, or omit. |
Fasteners | Guidance for specification option: Consult manufacturer for options and insert requirements, or omit. |
Jointing | Guidance for specification option: Consult manufacturer for options and insert requirements, or omit. |
System accessories | Euroclad Separation Tape. None. |
Colour/ Finish | Tata Steel Colorcoat Prisma®. Guidance for specification option:
Tata Steel Colorcoat Prisma® - Textured. Guidance for specification option:
Tata Steel Colorcoat HPS200 Ultra®. Guidance for specification option:
|
System depth | Manufacturer's standard. Guidance for specification option: Dependent on insulation thickness; see Thermal insulation guidance for details. |
Weight | Manufacturer's standard. Guidance for specification option: Dependent on insulation thickness; see Thermal insulation guidance for details. |
Orientation | Lengthwise, downslope. |
Sheet width | Cover width: 454 mm. Guidance for specification option: As standard. Can also be supplied in variable widths to give a concertina-style effect (on request). |
Third-party certification | BBA Certificate 04/4151 Product Sheet 4. |
Material | Steel Mineral wool |