Insulated built-up roof with an EC 75-400 Euroseam external profile.
Suitable for commercial and offices, distribution centres, education, industrial, mechanical, retail and transport applications.
Euroclad Elite 4 Range offers a low pitch standing seam roof option, with no endlaps and no exposed fixings.
The Euroseam® profile sheet can be used to achieve a whole range of curves from large barrel vaults to multiple curved designs. The Euroseam® profile can be supplied in natural stucco embossed aluminium, pre-painted PVDF, ARS, Duragloss or Organic Patina.
Features and benefits:
Finish | Coated |
Material | Glass mineral wool Mineral wool Aluminium Mineral fibre |
Shape | Other Guidance for specification option: Standing seam. |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | 25 year Guidance for specification option: Guaranteed for up to 30 years with the Elite Plus system guarantee. |
Uniclass | |
CAWS | H31/10 Metal H31/120 Metal |
System performance | External sheet coating fire performance: To BS EN 13501-5:2016, BROOF(T4). Guidance for specification option: By Commission Decision 2000/553/EC. |
Liner sheets | |
Material | EC 32-200-1000 Liner MW5. EC 32-200-1000 Liner MW5 Swaged 0.7 mm steel. |
Primary fasteners | Carbon steel fixings. Guidance for specification option: Elite guarantee. Stainless steel fixings. Guidance for specification option: Elite PLUS guarantee. |
End and side laps | Not required. |
Air and vapour control layer | |
Material | |
Sealing | |
Spacers | Quattro Bar and 80 mm Quattro Bracket. Guidance for specification option: System depth: 194.70 mm. U-value: NPD. Quattro Bar and 100 mm Quattro Bracket. Guidance for specification option: System depth: 214.70 mm. U-value: 0.34 W/m²K. Quattro Bar and 120 mm Quattro Bracket. Guidance for specification option: System depth: 234.70 mm. U-value: 0.30 W/m²K. Quattro Bar and 140 mm Quattro Bracket. Guidance for specification option: System depth: 254.70 mm. U-value: 0.26 W/m²K. Quattro Bar and 150 mm Quattro Bracket. Guidance for specification option: System depth: 264.70 mm. U-value: 0.25 W/m²K. Sound reduction: To BS EN ISO 10140-2:2010, 39 dB (-2;-8)(C/22349/T01). Quattro Bar and 160 mm Quattro Bracket. Guidance for specification option: System depth: 274.70 mm. U-value: 0.23 W/m²K. Quattro Bar and 170 mm Quattro Bracket. Guidance for specification option: System depth: 284.70 mm. U-value: 0.22 W/m²K. Quattro Bar and 180 mm Quattro Bracket. Guidance for specification option: System depth: 294.70 mm. U-value: 0.21 W/m²K. Quattro Bar and 185 mm Quattro Bracket. Guidance for specification option: System depth: 299.70 mm. U-value: 0.20 W/m²K. Quattro Bar and 200 mm Quattro Bracket. Guidance for specification option: System depth: 314.70 mm. U-value: 0.19 W/m²K. Quattro Bar and 220 mm Quattro Bracket. Guidance for specification option: System depth: 334.70 mm. U-value: 0.18 W/m²K. Sound reduction: To BS EN ISO 10140-2:2010, 42 dB (-2;-8)(C/22349/T01). Quattro Bar and 240 mm Quattro Bracket. Guidance for specification option: System depth: 354.70 mm. U-value: 0.16 W/m²K. Quattro Bar and 260 mm Quattro Bracket. Guidance for specification option: System depth: 374.70 mm. U-value: 0.15 W/m²K. Sound reduction: To BS EN ISO 10140-2:2010, 43 dB (-2;-7)(C/22349/T01). Quattro Bar and 280 mm Quattro Bracket. Guidance for specification option: System depth: 394.70 mm. U-value: 0.14 W/m²K. Quattro Bar and 300 mm Quattro Bracket. Guidance for specification option: System depth: 414.70 mm. U-value: 0.13 W/m²K. Quattro Bar and 320 mm Quattro Bracket. Guidance for specification option: System depth: 434.70 mm. U-value: 0.13 W/m²K. Quattro Bar and 340 mm Quattro Bracket. Guidance for specification option: System depth: 454.70 mm. U-value: 0.12 W/m²K. Quattro Bar and 360 mm Quattro Bracket. Guidance for specification option: System depth: 474.70 mm. U-value: 0.11 W/m²K. Quattro Bar and 380 mm Quattro Bracket. Guidance for specification option: System depth: 494.70 mm. U-value: 0.11 W/m²K. Quattro Bar and 400 mm Quattro Bracket. Guidance for specification option: System depth: 514.70 mm. U-value: 0.10 W/m²K. |
Thermal insulation | Knauf Factoryclad 40. Rockwool Cladding Roll. Superglass Cladding Mat. 40. Manufacturer guidanceDeclared lambda: 0.040 W/mK. |
External sheets | |
Material | EC 75-400 Euroseam 0.9 mm aluminium plain mill stucco embossed. EC 75-400 Euroseam 0.9 mm aluminium PVDF. EC 75-400 Euroseam 0.9 mm aluminium ARS. EC 75-400 Euroseam 0.9 mm aluminium organic patina. |
Primary fasteners | Carbon steel fixings. Guidance for specification option: Elite guarantee. Stainless steel fixings. Guidance for specification option: Elite PLUS guarantee. |
System accessories | Fasteners Standard U-value rooflights. Flashings. Membranes. Non-penetrative clamps. Guidance for specification option: For attachment of PV arrays and other roof mounted installations such as walkways. Tapes. Mastic and sealants. Fabrications. PV solutions. Fall arrest and fall restraint. Roof penetrations. Manufacturer guidanceConsult manufacturer for details. |
Material | Glass mineral wool Mineral wool Aluminium Mineral fibre |