NBS Source
I'm a manufacturer

UNITY DF A2 (Discrete Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Verified by manufacturer 2 months ago

Metalline Architectural Fabrications Third party certifications:
  • CWCT Certificate

    CWCT Certificate

    Certificate type

  • BS EN 13501-1

    BS EN 13501-1

    Certificate type

A versatile non-combustible rainscreen cassette system with a durable high-performance finish.

Jump to:
+44 (0)1543 456 930 Website

Application

Suitable for use on a range of construction projects.

Description

A versatile non-combustible rainscreen cassette system with a durable high-performance finish. Discrete fixings provide a streamlined appearance in both landscape and portrait orientation.


Features and benefits:

  • Manufactured from non-combustible material that has an A2-s1,d0 classification to BS EN 13501-1.
  • Developed and manufactured in accordance with CWCT guidelines.
  • Discrete fixings provide a streamlined appearance in both landscape and portrait orientation.
  • Available in Powder Coated, anodized or pre-coat finishes in an extensive range of colours.
  • Offers protection to a building’s external facade.
  • Can be used to enhance the look and feel of both new build and refurbishment projects.
  • Can be installed horizontally and vertically.
  • Panels available in lengths up to 6000 mm.
  • Unity rainscreen panels with associated carriers, bracketry and support systems are designed to allow the correct flow of ventilation and drainage run off in line with current building regulations.
  • Design assistance available; consult manufacturer for details.


Part of a range of Unity A2 systems (specified separately) that includes:



  • A through-fix rainscreen system (TF).
  • An interlocking rainscreen system (IL).
  • A secret-fix rainscreen system (SF).
  • An interlocking plank and soffit system (PS).


Installation:

Consult manufacturer's technical literature for details.

General information

Color

-

Manufacturer guidance

Extensive range of colours. Consult manufacturer and insert requirements

Finish

Powder-coated

Anodized

Galvanized

Mill

PVdF

Material

Aluminium

Length

Bespoke

Width

Bespoke

Height

Bespoke

Uniclass

Ss_25_20_70_25 Drained and back-ventilated rainscreen cladding systemsPrimary

CAWS

H92/120 Rainscreen cladding

Specification data - Drained and back-ventilated rainscreen cladding systems

System performance

Developed and manufactured in accordance with CWCT guidelines.

Thermal insulation

-

Manufacturer guidance

Insert requirements.

Breather membrane

-

Material

-

Manufacturer guidance

Insert requirements.

Secondary support structure

CLAD-LINE CL1 Sub-Frame System.

Guidance for specification option:

Aluminium support system comprising extruded vertical support rails (T/L profiled rails) with adjustable wall attachment brackets to suit cladding zone.


CLAD-LINE’s T and L profiled rails are fixed using the CL range of support brackets which provide up to 30 mm adjustment of the rail face. Fixed Point (dead load) brackets are designed to absorb vertical dead loads while the Sliding Point brackets allow for expansion and contraction and are designed to absorb wind loads.

CLAD-LINE F2F (Floor to Floor) Sub-Frame System.

Guidance for specification option:

Floor to floor spanning support system comprising an extruded vertical sheeting rail (Rail Type 1–2 mm face, Rail Type 2–4 mm face), a Primary Angle Bracket, a BS Link Bracket (allowing for up to 30 degree rotation), Link Bracket Fixing Assemblies, a Fixed Point Clip and a Sliding Point Clip (if required).

Manufacturer guidance

To EN 755, extruded aluminium, 6063/T6 grade alloy.

Cavity fire barriers

-

Horizontal

-

Manufacturer guidance

Insert requirements.

Vertical

-

Manufacturer guidance

Insert requirements.

Cladding panels

-

Material

Aluminium cassette panels.

Panel joints

Open joints.

Samples required

None.

Panel and finish samples.

Samples of fixings.

Fabrication samples.

Mock-up to validate details.

Guidance for specification option:

Insert required size and details.

Configuration

Horizontal.

Vertical.

Horizontal and vertical.

Horizontal corner section

Required.

Not required.

Panel length

Guidance for specification option:

Available up to 6000 mm; insert requirements.

Reaction to fire classification

To BS EN 13501-1, A2-s1, d0.

Finish

Powder coated.

Guidance for specification option:

60 µm.

Colour

-

Manufacturer guidance

An extensive range of colours available. Consult manufacturer and insert requirements.

Thickness

3 mm.

Joint width

-

Manufacturer guidance

Insert requirements, 10–20 mm.

Sheeting rails

Continous rails.

Individual rails.

Rail material/ finish

To EN 755, extruded aluminium, 6063/T6 grade alloy.

Sustainability data

Contains Red List materials

No

Country of material origin

United Kingdom

Country of product manufacture

United Kingdom

Material

Aluminium

Recyclability

100

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

65 %

Third party certifications

CWCT Certificate

CWCT Certificate

CWCT - Technical Report

CWCT Certificate

CWCT Certificate

CWCT - Testing Report

BS EN 13501-1

BS EN 13501-1

REACTION TO FIRE CLASSIFICATION - UNITY

Literature

Unity A2 DF-01 Technical Drawing

Unity A2 DF-01 Technical Drawing

Unity A2 DF-02 Technical Drawing

Unity A2 DF-02 Technical Drawing

Unity A2 DF-03 Technical Drawing

Unity A2 DF-03 Technical Drawing

Unity A2 DF-04 Technical Drawing

Unity A2 DF-04 Technical Drawing

Unity A2 DF-05 Technical Drawing

Unity A2 DF-05 Technical Drawing

Unity A2 DF-06 Technical Drawing

Unity A2 DF-06 Technical Drawing

Unity A2 DF-07 Technical Drawing

Unity A2 DF-07 Technical Drawing

Unity A2 DF-08 Technical Drawing

Unity A2 DF-08 Technical Drawing

Unity A2 DF-09 Technical Drawing

Unity A2 DF-09 Technical Drawing

Unity Aluminium Rainscreen Cladding - Technical Data Sheet

Unity Aluminium Rainscreen Cladding - Technical Data Sheet

Similar products from Metalline Architectural Fabrications

UNITY DF A1 (Discrete Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

UNITY DF A1 (Discrete Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

UNITY IL A1 (Interlocking Cassette Panel) Non-Combustible Aluminium Rainscreen Cladding

UNITY IL A1 (Interlocking Cassette Panel) Non-Combustible Aluminium Rainscreen Cladding

UNITY IL A2 (Interlocking Cassette) Non-Combustible Aluminium Rainscreen Cladding

UNITY IL A2 (Interlocking Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity SF A1 (Secret Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

Unity SF A1 (Secret Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding

UNITY SF A2 (Secret Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding - Rainscreen Cladding

UNITY SF A2 (Secret Fix Cassette) Non-Combustible Aluminium Rainscreen Cladding - Rainscreen Cladding

UNITY TF A1 (Through Fix) Non-Combustible Aluminium Rainscreen Cladding

UNITY TF A1 (Through Fix) Non-Combustible Aluminium Rainscreen Cladding

UNITY TF A2 (Through Fix) Non-Combustible Aluminium Rainscreen Cladding

UNITY TF A2 (Through Fix) Non-Combustible Aluminium Rainscreen Cladding

UNITY X-TRU A1 (Extruded Plank) Aluminium Rainscreen

UNITY X-TRU A1 (Extruded Plank) Aluminium Rainscreen

UNITY X-TRU A2 (Extruded Plank) Aluminium Rainscreen  - Extruded Plank Aluminium Rainscreen

UNITY X-TRU A2 (Extruded Plank) Aluminium Rainscreen - Extruded Plank Aluminium Rainscreen