Trimapanel® Flat - 70 mm panel thickness
QA Certificate
Certificate type
Insulated, secret-fix, flat architectural wall cladding panel system.
Suitable for vertical or horizontal architectural wall cladding applications.
Trimapanel® Flat is a steel insulated, secret-fix, flat architectural wall-cladding panel which is quick and easy to install for fast build times. Available in a range of sizes, shapes and colours and with extensive fabrication options, it offers design flexibility which enables architects to create unique and modern design solutions. Single, double and multi span configurations are available.
Features and benefits:
Fire performance:
Trimapanel® Flat carries Grade EXT-B and EXT-A approval by the LPCB. Also fire resistance performance of up to four hours integrity and 15 mins insulation. These are attained by stitching the liner face at 250mm centres.
The internal surface of the panel complies with a Class B s2 d0 rating in accordance with EN 13501-1.
Water penetration:
The Trimapanel® Flat system's joint is water-tight up to a pressure of 1050 Pa, when tested to BS EN 12865‘Hygrothermal performance of building components and building elements'.
Air-tightness:
In accordance with Building Regulations Approved Document L2 (E&W) and Scotland (Technical Handbook Section 6 Energy) tests to EN BS 12114 shows the sealed panel of air leakage as low as 0.48 m³/h/m² at an applied pressure of 50 Pa.
A practical expectation for a finished building, with effective sealing at all junctions, would be 5-10 m³/h/m². However, enhanced detailing practises on large shed buildings can realise air leakage performance figures of less than 3 m³/h/m².
Thermal performance:
The panel construction offers highly consistent insulation performance, and the site formed junctions provide a practical and effective method of ensuring good thermal performance.
U-values:
Acoustic performance/ Sound reduction (SRI) weighted values:
Based on a 70 mm core, weighted SRI Rw: 28.9 dB, consult technical literature for further details.
ShapeFlat profile. | - |
FinishColorcoat options. | - |
Material | Steel Pre-coated steel skins/ PIR core. |
SizeTo suit project requirements. | - |
Uniclass | |
CAWS | H43/10 Metal insulating sandwich panel H43/120 Metal insulating sandwich panel |
Cladding panels | - |
Panel type | Carbon steel insulating sandwich panels |
Continuity thermal insulation | PIR closed cell foam.(CFC and HCFC free, zero ODP and GWP <5) to the specification used in LPCB approval. |
System accessories | None.Corner panel.Curved panel.Flashing. |
Product Reference | Trimapanel® Flat |
Material | Colorcoat HPS200 Ultra® pre-finished steel. |
Profile | Flat face with tongue and groove edges. Skin thickness: 0.7 mm. |
Material | Colorcoat® High Reflect pre-finished steel. Colorcoat® PE 15 pre-finished steel. |
Profile | Planked, with tongue and groove edges. Skin thickness: 0.4 mm. |
LengthPanel lengths up to 12 m. | - |
Cover width | 600 mm. 900 mm. 1000 mm. |
Thickness | 70 mm. |
Panel internal face | The internal surface of the panel complies with reaction to fire Class B-s2 in accordance with BS EN 13501-1. |
Combustibility | The system carries Grade EXT-B and EXT-A approved by the LPCB. |
Fire resistanceContact the technical department for specification details. | 15 minutes fire insulation resistance. 240 minutes fire insulation resistance. |
Material | Pre-finished steel. |
ColourInsert requirements. | - |
Material | Pre-finished steel. |
ColourInsert requirements. | - |
Span | As drawing. Insert details. |
Weight | 11.89 kg/m². |
U-value | 0.31 W/m²K. |
Impact sound reductionWeighted SRI Rw. | 28.9 dB. Based on a 70 mm core, consult technical literature for further details. |
Colorcoat® LG colour card
Colorcoat HPS200 Ultra Colourcard
Colorcoat HPS200 Ultra Technical Brochure
Photovoltaic installation guidelines for industrial and commercial buildings
Acoustic performance of pre-finished steel cladding systems
Structural performance of built-up roof and wall cladding systems
Ensuring consistent appearance of pre-finished steel wall cladding
Refurbishment solutions for non-domestic solutions
The effect of gauge on pre-finished steel roof and wall cladding performance
Creating an air-tight building envelope
Colorcoat Prisma® Colourcard