NBS Source
I'm a manufacturer

Thermaweld FireSmart Mineral

Verified by manufacturer 12 days ago

BMI Group UK Ltd

Reinforced bitumen roof waterproofing system.

Jump to:
0370 560 1000 Website

Application

  • Suitable for use as the capsheet within a bituminous built-up roofing system.
  • Developed for use in high-performance built-up systems on flat, pitched or curved roofs.
  • Hydrocarbon solvent-based products, such as Naphtha, paraffin and creosote will have a harmful effect and should not be allowed to come in to contact with these membranes.

Description

A polyester reinforced, styrene butadiene styrene (SBS) modified bitumen membrane with enhanced fire performance (spread of flame and fire penetration). The polyester carrier is impregnated and then coated in FireSmart SBS modified bitumen. The upper surface is coated with mineral granules and given a 120 mm wide mineral-free selvedge finished with a thermofusible film. The underside is given a special grooved profile for torch-on application and is finished with a thermofusible film to prevent sticking in the roll.


Features and benefits:

  • The material is impervious to water.
  • Unaffected by freeze/ thaw cycling, will support temperatures from -20 °C to 90 °C without damage.
  • Not susceptible to insect attack or pest damage and is unaffected by fungi, moss, lichen, moulds or bacteria.
  • Compatible with most building materials with which it is likely to come in to contact with during roofing works.
  • Correctly installed and maintained systems incorporating the capsheet may be expected to last in excess of 20 years.
  • The self-finished mineral surface provides a decorative and solar reflective finish for the built-up waterproofing system.
  • When incorporated in a suitably designed multilayer system they will greatly improve the long-term performance of that system.
  • The membrane utilizes a special grooved adhesion technology.
  • CE marked (EN 13707, 13, 0086-CPD-505779).


FireSmart Technology:

  • Membranes are formulated using finely ground volcanic silicone rock which has withstood temperatures in excess of 5000°C. When a flame comes in to contact with the surface of the membrane, the presence of volcanic rock brings about an endothermic reaction within the membrane. Heat is drawn from the flame to support a process of carbonization in the membrane, so reducing the burn temperature. The resulting unbroken carbonised ‘shell’ then seals off combustible material beneath, denying the already-weakened flame further fuel and preventing any further combustion.

General information

Color

Blue

Grey

Black

Green

Brown

Material

Bitumen

Guidance for specification option:

Styrene butadiene styrene (SBS) modified.

Polyethylene

Guidance for specification option:

Thermofusible polyethene (PE) film.

Polyester

Shape

Other

Length

7000 mm

Width

1000 mm

Uniclass

Pr_25_57_08_75 Reinforced bitumen roofing sheetsPrimary

CAWS

J41/10 Reinforced bitumen membrane warm deck roof covering

J41/110 Built-up reinforced bitumen membrane warm deck roof covering

J41/12 Reinforced bitumen membrane cold deck roof covering

J41/120 Built-up reinforced bitumen membrane inverted roof covering

J41/130 Built-up reinforced bitumen membrane cold deck roof covering

J41/405 Single-layer reinforced bitumen waterproof covering

Specification data - Reinforced bitumen roofing sheets

Classification data

Standard

To BS EN 13707.

Material

-

Carrier material

Polyester.

Bitumen modification

Elastomeric.

Thickness (minimum)

4.5 mm.

Weight (minimum)

42 kg.

Surface finish

-

Top

Mineral granules with thermofusible film to overlap selvedge.

Underside

Thermofusible film.

Colour

Green.
Brown.
Noxite.
Charcoal.
Blue-grey.

Material:

Styrene butadiene styrene (SBS) modified bitumen.

Reinforcement

Polyester.

Width

125 mm.

Manufacturer guidance

Selvedge width.

Mass per unit area

To EN 1849-1, 6 kg/m².

Watertightness

To EN 1928 (B), pass.

Reaction to fire class

To EN 13501-1, class F.

Fire performance

To EN 13501-5, FRoof (t4).

Manufacturer guidance

  • The external fire performance of a roof is dominated by the built-up roof system.
  • No performance can be assessed for the product alone.

TensileStrength

To EN 12311-2 (A), 900 N/50 mm (MD and TD).

Elongation

To EN 12311-2 (A), 35% (MD and TD).

Dimensional stability

To EN 1107-1, ≤1%.

Flexibility at low temperature

To EN 1109, ≤-20°C.

Ageing

To EN 1296, pass.

Manufacturer guidance

Artificial ageing behaviour.

Adhesion

To EN 12039, <30%.

Manufacturer guidance

Adhesion of granules.

FlowResistanceRange

To EN 1110, >75°C.

Manufacturer guidance

Flow resistance at elevated temperature.

Similar products from BMI Group UK Ltd

Monarflex EavesGuard

Monofilament 250 Vapour Control Layer

Profiles Vapour-Vent XL

Reflex 275 Vapour Control Layer

Tecnatorch® Sand

TorchSafe T.A. VCL - Sand

TorchSafe T.A. VCL - Stripes

TorchSafe T.A. VCL - Stripes Vapour Control Layer

Total Torch Vapour Control Layer

Total Torch Vapour Dispersion Layer