Application

Suitable for applications including:

  • Cavity internal and external wall leaves.
  • Solid external walls.
  • Separating walls.
  • Internal partitions.

Description

Thermalite Hi-Strength 7 provides a solution for seamless wall construction, designed to match the coordinating heights of standard masonry units and enhance structural integrity, ensuring uniform thermal performance throughout the wall.

Manufactured in accordance with BS EN 771-4, it complies with all relevant Masonry Wall Robust Details and supports compliance with Building Regulations – Approved Documents Part A, B, E & L.

Features and benefits:

  • Versatile for accommodating openings, level adjustments, and complex wall geometry.
  • Low air permeability.
  • Produced in standard brick height and block length.
  • Suitable for different applications.
  • High-strength coursing block with a compressive strength of 7.3 N/mm².
  • BBA-certified.
  • BES 6001-certified.

General information

Color

Grey

Finish

Micro-textured

Material

Autoclaved aerated concrete (AAC)

Shape

Rectangle

Length

440 mm

Width

100 mm

140 mm

Height

65 mm

140 mm

Uniclass

Pr_20_93_52_05 Autoclaved aerated concrete (AAC) blocksPrimary

CAWS

F1/310 Aerated concrete blocks

F10/370 Thin-joint autoclaved aerated concrete (AAC) common blockwork

F10/360 Autoclaved aerated concrete (AAC) common blockwork

F10/37 Autoclaved aerated concrete (AAC) common blockwork

F10/39 Thin joint autoclaved aerated concrete (AAC) common blockwork

Specification data - Autoclaved aerated concrete (AAC) blocks

Classification data

Standard

To BS EN 771-4.

Environmental performance requirements

-

Environmental rating

BES 6001-certified.

Configuration

Group 1.

Guidance for specification option:

Solid.

Mean compressive strength (minimum)

-

Category

II.

Freeze-thaw resistance

Not to be left exposed.

Thermal conductivity (maximum)

0.18 W/mK.

Guidance for specification option:

  • Thermal Conductivity - λ10, dry unit, S2: 0.16 W/mK.
  • Design thermal conductivity protected (3%): 0.18 W/mK.
  • Design thermal conductivity exposed (5%): 0.20 W/mK.
  • Design thermal conductivity below DPC level: 0.29 W/mK.

Work sizes (length x width x height)

440 x 100 x 65 mm.

Guidance for specification option:

Tolerances:

  • Length and height: +3/ - 5 mm.
  • Width: +/-3 mm.

Accessories or special shapes

-

Type

Coursing blocks.

Tolerance category

GPLM.

Density

730 kg/m³.

Manufacturer guidance

Gross dry density.

Reaction to fire

Class A1 to BS EN 13501-1.

Moisture movement

0.5 mm/m.

Manufacturer guidance

Nominal value.

Shear bond strength

0.15 N/mm².

Water vapour permeability

5/10.

Unit weight

2.7 kg.

Manufacturer guidance

Gross density + 50 kg/m³ at 23% moisture.

Mean compressive strength (minimum)

7.3 N/mm².

Thermal Conductivity:

λ10, dry unit, S2, 0.16 W/m·K.
Protected (3%): 0.18 W/m·K.
Exposed (5%): 0.20 W/m·K.
Below DPC level: 0.29 W/m·K.

Thermal resistance

Protected (3%): 0.555 m²K/W.
Exposed (5%): 0.5 m²K/W.

Sound reduction

42.3 Rw dB.

Guidance for specification option:

Unfinished.

Vapour resistivity

50 MN·s/g·m.

Third-party certification

BBA certificate 00/3720 Product Sheet 1.

Sustainability data

Country of product manufacture

United Kingdom

Material

Autoclaved aerated concrete (AAC)

Recyclability

Yes

Recycled content

As defined in clause 7.8 of BS EN ISO 14021

80 %