Technishield 50 Non-rebated Double Door

Description

A framed, double-leaf, non-rebated, fire-rated glass doorset on hinges for use in conjunction with Technishield 50 partition system, offering either 30 or 60 minutes' integrity. Part M-compliant clear opening included.

General information

Size

As drawing

As schedule

Uniclass 2015

Pr_30_59_24_52 Metal doorsetsPrimary

CAWS

L20/480 Doorsets

L20/55 Doorsets

Specification data - Metal doorsets

Product Reference

Technishield 50 Non-rebated Double Door

Size

As drawing

As schedule

FireRating

E30

30 minutes' integrity (30/0).

E60

60 minutes' integrity (60/0).

Side-panels/ over-panels

Not required

Over panel

Side panel both sides

Side panel left side

Side panel right side

Over panel and side panel

Insert requirements.

Finish/ Colour

Powder-coated, RAL

Insert requirement; contact manufacturer for more information.

Powder-coated, RAL 9006 Silver

50 microns, 30% gloss (nominal).

Powder-coated, RAL 9010 White

50 microns, 30% gloss (nominal).

Manifestation

Insert requirements.

Standard product features

Hinges:

Two face-fitted, weld-on hinges per leaf.

Handles:

Forster stainless steel cranked pull handles

Lock:

Not available.

Slave door lock:

Not applicable.

Euro cylinder:

Not applicable.

Door closer:

TS-93 2-4.

Dropseal:

Type RO drop seals.

Door seals:

Fire and smoke protection double-seal.

Product Options

Size:

  • Door: With over-panel: Available 1850–2800 x 2200–4000 mm (w x h); without over-panel: Available 1850–2500 x 1800–2625 mm (w x h). All dimensions subject to specification and certification.
  • Side panel: Available 300–1100 mm in width.