Verified by manufacturer 4 months ago
Aluminium Profiled Sheets - Vertical
CWCT Certificate
Certificate type
Half-round sinusoidal vertically or horizontally laid wall cladding system.
Wall cladding profiles.
Applications include: Educational and leisure facilities, commercial premises, offices and manufacturing facilities.
Vertically or horizontally laid half-round sinusoidal wall cladding system.
Features and benefits:
System components:
Color | Silver Guidance for specification option: Aluminium or steel. Other Guidance for specification option: Standard and RAL colours available. Manufacturer guidanceAluminium/ Steel: Standard APL Range; Bespoke upon request. Cor-Ten: Unweathered. |
Finish | Powder-coated Guidance for specification option: Class 1 or Class 2 Full RAL colour range and / or contact APL for additional finishes such as anodised-look Anodized Guidance for specification option: Contact APL for details Natural Guidance for specification option: Smooth mill-finish aluminium Unweathered Cor-Ten Embossed Guidance for specification option: Stucco-embossed mill-finish aluminium or Armacoil™ HDP (Subject to minimum quantity) Painted Guidance for specification option: Aluminium with Armacoil™ HDP (Subject to minimum quantity) Steel with APL PUF or PRISMA Manufacturer guidancePPC, Armacoil™ HDP, Anodised, APL PUF, Stucco-Embossed Mill-Finish (SEMF), Smooth Mill Finish (MF). Natural, PRISMA |
Material | Aluminium Guidance for specification option: Solid and perforated. Steel Cor-Ten Guidance for specification option: Solid and perforated. |
Shape | Other Guidance for specification option: Sinusoidal, half-round Manufacturer guidanceSinusoidal, half-round |
Length | Bespoke |
Width | 1000 mm Guidance for specification option: Cover width. |
Height | 40 mm |
Warranty description | 25 year Guidance for specification option: Up to 25 years subject to location. Cladshield™ fully-installed system warranty available; consult manufacturer for details. |
Uniclass | |
CAWS | H92/120 Rainscreen cladding H31/10 Metal H31/120 Metal |
System performance | Manufacturer guidanceInsert requirements. |
Liner sheets | |
Material | Not required.Guidance for specification option: SFS/ blockwork/ timber. AP19 LPH profile in 0.4 mm steel in off-white 80F - solid.Guidance for specification option: Where onto cladding rails. APL StrongBak™.Guidance for specification option: Long-span, non-combustible structural cladding system based upon Kassett construction principles. To be specified separately. |
Primary fasteners | APL P191/HH fixing range.Guidance for specification option: Manufacturer's standard, consult manufacturer for details. |
End and side laps | Minimum 75 mm; APL P191/HH fixing range at one per mid span, APL P103 + P108/VCT side lap sealant range, P152 Flute Fillers. |
Air and vapour control layer | |
Material | AP19 LPH Liner sheet.Guidance for specification option: Cladding rails. APL StrongBak™.Guidance for specification option: To be specified separately. Other.Guidance for specification option: SFS/Blockwork substrate/Timber - refer to relevant manufacturer. |
Fasteners | APL P191/HH fixing range.Guidance for specification option: Cladding rails. Other.Guidance for specification option: SFS/ blockwork/ timber - refer to relevant manufacturer. |
Sealing | APL P191/HH fixing range (side laps sealed with 2x runs of P108/VCT).Guidance for specification option: Cladding rails. Other.Guidance for specification option: SFS/ blockwork/ timber - refer to relevant manufacturer. |
Spacers | Tritherm Spacer System℗ - Fully-Filled Cavity.Guidance for specification option:
Tritherm Spacer System℗ - Ventilated Cavity (CWCT-Tested).Guidance for specification option: SFS/ blockwork/ timber: P618 Tophat, P665-ALU RWB, P546 Isopad, P157-ALU HH Bracket, P754 + P785 ALU Zed. Tritherm Spacer System℗ - Ventilated Cavity.Guidance for specification option: SFS/ blockwork/ timber: P521/4 + P528/4 HH brackets, P759 vertical ALU "L" rail, P754 ALU Zed. Manufacturer guidanceSpacers are fixed with APL P191/HH range. For U-value information, please review attached literature items. Additional U-values available – consult manufacturer for details. |
Acoustic insulation | A1-rated with thickness and performance specification as required to meet performance.Guidance for specification option: Contact manufacturer for details and insert details as required. |
Thermal insulation | A1-rated.Guidance for specification option: Thickness as required to meet U-value requirement with minimum lambda of 0.040 for all calculation purposes:
Refer to the relevant U-value table in the supporting literature. |
External sheets | |
Material | 45HR aluminium profiled sheets - solid.45HR aluminium profiled sheets - Airwall™ (perforated).Manufacturer guidanceCover width: 1000 mm. Profile width: 166 mm. |
Primary fasteners | APL 191/LP fixing range; valley fix at every corrugation at end laps and every other corrugation elsewhere - colour matched as required. |
Secondary fixings | APL 191/LP fixing range - colour matched as required. |
End and side laps | End laps: 125 mm; APL 191/LP fixing range - colour matched as required.Guidance for specification option: Side laps stitched at maximum 400 mm centres; APL P109/GGB sealant 6 mm diameter for side laps and end laps; APL P152/HP Flute Fillers; GE/F1 flashing at system joints; GEX/F2 flashing at corners. |
Wall glazing | Required.Guidance for specification option: Consult manufacturer for options and insert requirements. Not required. |
System accessories | APL Fixings.Guidance for specification option: P191 & P192. APL Sealants.APL System Flashings.Guidance for specification option: Including GE/F1 & GEX/F2 at system joints. Clamp-End Lap.Guidance for specification option: Use P151 angle fixed to P600 with P109/GGB sealant at overlap to stop-scratching. P152 Profile Flute Fillers.Guidance for specification option: As per APL recommendations and to match profiles. |
Colour/ Finish | Armacoil™ HDP. Guidance for specification option: Subject to minimum quantities. Insert colour required. Anodized. Guidance for specification option: Contact APL for details. Polyester powder-coating, class 1. Guidance for specification option: Insert colour/ finish required. Polyester powder-coating, class 2. Guidance for specification option: Insert colour/ finish required. Stucco-Embossed Mill-Finish (SEMF). Manufacturer guidanceInsert colour requirements. |
Orientation | Vertical. |
Minimum bearing area | 50 mm. |
NominalThickness | 0.9 mm. |
Liner Supports | Guidance for specification option: Subject to loadings. Centres are to general areas only, closer at high load zones.
|
Recycled content (minimum) | Up to 95%. |
Profile supports | Manufacturer guidanceSubject to loadings. Centres are to general areas only, closer at high load zones.
|
Contains Red List materials | No |
Country of product manufacture | United Kingdom |
Recyclability | High |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | % Guidance for specification option: Subject to substrate (steel or aluminium) and grade of aluminium |
AP45HR - Aluminium - Cladding Data Sheet
AP45HR - Steel - Cladding Data Sheet
APL Liner Profiles - Roofing & Cladding - Data Sheet
APL Liner Profiles - Roofing & Cladding - System Summary
APL Tritherm Spacer System℗ - Aluminium - Data Sheet
APL Tritherm Steel Spacer System - Cladding - System Summary
U-Values + Build Up - WALLS - Horizontal Orientation to Cladding Rails
U-Values + Build Up - WALLS - Vertical Orientation to Cladding Rails
U-Values + Build Up - WALLS - Horizontal Orientation to SFS / Blockwork
U-Values + Build Up - WALLS - Vertical Orientation to SFS / Blockwork
APL Airwall™ - System Summary
APL Armacoil™HDP + HDP-HT - Product Brochure
APL StrongBak™ - Cladding - System Brochure
APL Cladding - Automotive System Brochure
APL Cladding - Sinusoidal Profiles - System Summary
APL Cladding Systems Brochure
APL StrongBak™ - System Summary
APL AluE™ Tritherm™ Aluminium Spacer System - Cladding - System Summary
APL Case Study - Aluminium Sinusoidal Firewall - Nathan Way, Woolwich
APL Case Study - Aluminium Sinusoidal Roofing & Perforated Cladding - Birmingham Energy Innovation Centre
APL Case Study - AP65ZS Zipseam™ Roofing & Sinusoidal, Slimwall™ & Louvre Cladding - CMR Medical
APL Case Study - APL StrongBak™ & Sinusoidal Cladding - GTIMC, University of Sheffield
APL Case Study - Perforated Sinusoidal Airwall™ Cladding - Marlborough College Innovation Centre
Concave / Half-Round Profile Wall System - AP50-Curveline™ - Concave Profile Cladding System
Corrugated / Sinusoidal (19mm Deep) Profile Wall System - AP18HR - Sinusoidal Profile Cladding System
Custom Bespoke Profile Wall Systems - AP-CBP Range - Custom Profile Cladding System
Discreet Fix Flat Panel Rainscreen Cladding System - APL Slimwall™ CPS/SSF - Rainscreen Flat Panel Cladding System
Face-Fix Flat Panel Rainscreen Cladding System - APL Slimwall™ (FF) - Flat Panel Rainscreen Cladding System
Half-Round Profile Wall System - AP50HR - Half-round Profile Cladding System
Long-span Structural Wall Panel System - APL StrongBak™ - Non-Combustible
Louvre Profile Wall Cladding System - AP70 LCP - Louvre Profile Cladding System
Louvre System - Live Louvres - APL LB3 & LB4 - Live Louvre System
Secret-Fix Flat Plank & Panel Rainscreen Cladding System - APL Slimwall™ SFP - Secret-Fix Rainscreen Panel