Schöck Isokorb® XT - Load-bearing Thermal Insulation Element

Verified by manufacturer 2 months ago

Schöck Isokorb® XT Type A

Schöck Ltd Variant:
Third party certifications:
  • BBA Agrément Certificate

    BBA Agrément Certificate

    Certificate type

Load-bearing thermal insulation element for concrete-concrete structures with 120 mm insulation thickness.

Jump to:
+44 (0)1865 290 890 Website

Application

Regardless of whether you want to build cantilevered or supported balconies, recessed balconies, access balconies, canopy roofs, corner balconies or height offset balconies: The versatile and extensive range of the Schöck Isokorb® XT for reinforced concrete and steel connections offers the right thermal insulation solution for each requirement.

Description

Load-bearing thermal insulation element for concrete-concrete structures with 120 mm insulation thickness.

General information

Color

Silver

Material

Polystyrene

Stainless steel

Shape

Rectangle

Length

1000 mm

500 mm

Width

120 mm

Height

160 mm

170 mm

180 mm

190 mm

200 mm

Show more

Warranty description

60 year

Uniclass

Pr_35_90_15_88 Thermal break shear load connectorsPrimary

CAWS

E42/110 Accessories specified elsewhere

E42/110 Accessories specified elsewhere

E42/335 Shear load connectors

E42/335 Shear Load Connectors

Specification data - Thermal break shear load connectors

Certification

BBA certificate 05/4277.
European Technical Assessment ETA-17/0261 or ETA-17/0262.

Guidance for specification option:

Consult manufacturer for details of applicable ETA.

Material

Stainless steel with Neopor® polystyrene hard foam.

Thickness of structural deck

Guidance for specification option:

Insert requirements, consult manufacturer's literature for information.

Shear load (maximum)

Guidance for specification option:

Insert requirements for internal static force of the main load capacity and secondary load-bearing level.


Consult manufacturer's literature for information.

Fire resistance

REI 120.

Guidance for specification option:

Can be specified with no fire resistance (R0) if required, consult manufacturer for details.

Manufacturer guidance

To BS EN 13501-2.

Type

A.

Guidance for specification option:

Load-bearing thermal insulation element with 120 mm insulation thickness for parapets.


  • Standardized: Available in standard heights of 160–250 mm; other heights and constructions available on request.
  • Fire resistance class R90: Also available in fire resistance class R90.
  • Best possible thermal insulation: With 120 mm insulation thickness.
  • No thermal bridges or seal integrity problems: The attachment of fasteners, hand rails or covers is possible without difficulty.
  • Certified Passive House component: Certified by the Passive House Institute in Darmstadt, Germany: negative psi value is useful for enhancing the thermal bridge balance in the building.
  • Enhanced design scope: From being able to use architectural concrete.
  • Larger terrace areas: Raises the value of the living unit.
  • No need of tedious wrapping: Efficient and maintenance free alternative to wrapped parapets and balustrades with insulation material.

Dimensions

Guidance for specification option:

Insert requirements to describe:

  • Concrete cover (CV);
  • Bond length (LR) and height (HR);
  • Insulating element height (H); length (L) and/or width (W);
  • Diameter of thread (D).


Note that insulating element thickness is fixed at 120 mm.

Manufacturer guidance

Consult manufacturer's literature for further details.

Insulation

120 mm insulating element.

Sustainability data

Country of material origin

Germany

Country of product manufacture

Germany

Third party certifications

BBA Agrément Certificate

BBA Agrément Certificate