Verified by manufacturer 5 months ago
A fully adhered, single ply EPDM warm roof system.
The RubberGard™ EPDM Fully Adhered System is a lightweight system with design flexibility. The membrane is fully adhered directly to the substrate using Elevate bonding adhesive.
Features and benefits:
System components:
Color | Black |
Material | Rubber Polyisocyanurate (PIR) |
Shape | Rectangle |
WidthSpecifically designed for best compatibility in fully adhered systems and have no folds. | 3050 mm 5080 mm |
Height | 1.1 mm 1.5 mm |
Uniclass | |
CAWS | J42/10 Warm deck roof covering J42/110 Warm deck roof covering |
Preparation | - |
Horizontal work | SA-19 Primer.Firestone SA-19 Primer is used to prime and prepare exterior concrete, wood, and metal surfaces to enhance the adhesion of Firestone V-Gard vapour control membrane. It's also used to prime seams when required. |
Skirtings and vertical work | SA-19 Primer.Firestone SA-19 Primer is used to prime and prepare exterior concrete, wood, and metal surfaces to enhance the adhesion of Firestone V-Gard vapour control membrane. It's also used to prime seams when required. |
Air and vapour control layer | - |
Type | V-Gard Vapor Control layer.Firestone V-Gard Vapor Control Membrane is designed to be used as a vapor control layer in Firestone roofing systems. It consists of a reinforced aluminium foil with self-adhesive bituminous backing protected by a release film. The fiberglass reinforcement makes it suitable for applications that involve high mechanical stresses. The Firestone V-Gard membrane can be installed on concrete, wood and steel deck. |
Attachment | Self-adhesive bituminous backing. |
Insulation | - |
TypeConsult the manufacturer's Technical Services Department for R-Value/U-value calculations as required. | ISOGARD AK PIR Insulation.Thermal conductivity: 0.023 W/m.K. Thickness: 30–160 mm. Insert requirements. Firestone ISOGARD AK insulation board consists of a closed-cell polyiso (PIR) foam core laminated on both sides to a gastight multi-layered aluminium complex. ISOGARD MG PIR Insulation.Thermal conductivity: 0.025–0.028 W/m.K. Thickness: 30–160 mm. Insert requirements. Firestone ISOGARD MG insulation board consists of a closed-cell polyiso (PIR) foam core laminated on both sides to a gasopen mineral glassfibre facer. RESISTA AK PIR Insulation.Thermal conductivity: 0.023 W/m.K. Thickness: 30–160 mm. Insert requirements. RESISTA AK PIR insulation board consists of a closed-cell polyiso (PIR) foam core laminated on both sides to a gastight multi-layered aluminium complex. RESISTA MG PIR Insulation.Thermal conductivity: 0.025–0.028 W/m.K. Thickness: 30–160 mm. Insert requirements. RESISTA MG PIR insulation board consists of a closed-cell polyiso (PIR) foam core laminated on both sides to a gasopen mineral glassfibre facer. ISOGARD HD cover board.An optional, lightweight, high-density polyiso (PIR) foam cover board of 12.7 mm thickness, with coated fiberglass facers to both sides, which is used to protect the insulation layer beneath and may also be used as a recovery board. It provides an optimum surface for fully adhered Firestone roofing membranes. |
Attachment | I.S.O. Twin Pack Insulation Adhesive.Firestone I.S.O. Twin Pack Insulation Adhesive is a two-component low-rise polyurethane adhesive designed for anchoring acceptable roof insulation and cover boards to an acceptable substrate, as well as for adhering multiple layers of insulation. It is a solvent-free insulation adhesive that contains no harmful HCFC or CFC. |
Waterproof covering | - |
Type100% cured non-reinforced, Ethylene-Propylene-Diene Terpolymer (EPDM) synthetic rubber, manufactured in an ISO 9001 and ISO 14001 registered facility. Minimum unspliced width of 3.05 m. Specification compliance: UL Classified/ FM Approved. ASTM D 4637/ EN 13956 (CE Mark). 7500 hrs of Artificial Ageing as per EN 1297. | RubberGard™ EPDM LSFR Roofing Membrane 1.1 mm.1.1 mm thickness is recommended for general roofing applications where access and foot traffic is infrequent. RubberGard™ EPDM LSFR Roofing Membrane 1.5 mm.1.5 mm thickness is recommended for roofs requiring higher levels of foot traffic, green roofs, blue roofs, PV roofs etc. |
AttachmentSuper spreader or roller applied contact adhesives. Contact the manufacturer's Technical Department for details on defining the proper method of attachment for the substrate. | BA-2012 Bonding Adhesive.BA-2004(T) Bonding Adhesive. |
Joints | 100 mm minimum overlap with 76 mm QuickSeam Splice Tape. |
Surface protection | QuickSeam Walkway Pads.760 x 760 mm high quality rubber pads with QuickSeam Tape factory laminated to the bottom. They are used for protection of the Firestone RubberGard EPDM membrane in areas of regular roof traffic (periodical maintenance around mechanical equipment, access doors, etc.). |
System accessories | QuickSeam Splice Tape.QuickSeam FormFlash.QuickSeam Flashing.QuickSeam SA Flashing.QuickSeam Reinforced Perimeter Fastening Strip.QuickSeam Universal Pipe Flashing.QuickSeam Conduit Flashing.QuickSeam Penetration Pocket.QuickSeam Walkway Pad.QuickPrime Plus.Lap Sealant HS.All Purpose (AP) Fasteners.Heavy Duty (HD) Fasteners.Splice Wash (SW-100).Cleaner C-20.Water-Block Seal (S-20).Pourable Sealer S-10 (Parts A & B).Coiled Metal Batten Strip.Metal Batten Strip.Termination Bar.V-Plates. |
Corners | QuickSeam FormFlash. Used to form internal and external corners. RubberGard EPDM membrane. As an option on low upstands, internal corners may also be achieved by folding and adhering the RubberGard EPDM membrane to the upstand. |
Pipes | Pipe penetrations: QuickSeam FormFlash. Pipe penetrations: QuickSeam Universal Pipe Flashing and Conduit Flashing. |
Outlets | Drains: Install Water Block Seal (S-20) between membrane and outlet bowl. Secure membrane mechanically to outlet using integral clamping ring. Drains: Insert outlet bedded on Water Block Seal (S-20). Secure and flash with QuickSeam FormFlash or SA Flashing. |
Walls | Wall terminations: Termination bar, fastened with Water Block Seal (S-20) and Lap Sealant HS installed along top edge. @200 mm (maximum) o.c. Wall terminations: Metal batten bar fastened with surface mounted or inserted metal counter flashing protection. @150 mm (maximum) o.c. Wall terminations: Metal capping or concrete coping stones. Wall termination: Preformed metal edge trim. An appropriate metal edge trim will be prefabricated and installed with fasteners @ max. 100 mm centers. The edge trim will be sealed with QuickSeam Flashing. |
Platform | Compatible | Version |
---|---|---|
![]() | - | 1 |
RubberGard™ EPDM Ballasted Warm Roof System
RubberGard™ EPDM Inverted Warm Roof System
RubberGard™ EPDM Mechanically Attached Warm Roof System
UltraPly™ TPO Inverted Warm Roof System
UltraPly™ TPO Ballasted Warm Roof System
UltraPly™ TPO Fully Adhered Warm Roof System
UltraPly™ TPO Mechanically Attached Warm Roof System