Suitable for rainscreen facade applications.

Description

The Recess-Fixed Cassette offers a value engineered alternative to the Hook-on Cassette system that can be installed both vertically and horizontally. The cassette system is restrained on all four edges with colour matched rivets within the joint.


Corten A weathered steel is a weather resistant steel created by alloying copper, chromium and nickel and adding phosphorous which makes the material best suited for aesthetic facades. The top layer of the material reacts with atmospheric elements to form a rust coloured protective layer which not only makes the steel virtually maintenance free but also creates a striking aesthetic appearance.


Due to the nature of Corten, rainwater run-off may cause staining due to the rainwater partially washing away the rusted surface. Therefore, special design and drainage considerations should be taken to ensure that the rainwater run-off is channelled into a specific route to ensure that the contaminated rainwater does not cause any staining.


Features and benefits:

  • Available in 2 or 3 mm Corten A weathered steel.
  • Consult manufacturer for information on Corten sizes.


Quality and Durability:

Kingspan insulated panels are manufactured from the highest quality materials, using state of the art production equipment to rigorous quality control standards, complying with:

  • BS EN ISO 14001 panels are manufactured under Environmental Management System Certification.
  • BS EN ISO 9001 standard, ensuring long term reliability and service life.
  • BS EN ISO 50001 Energy Management System Certification.
  • BS EN ISO 45001 Occupational Health and Safety Certification.
  • BS EN ISO 37301 Compliance Management Systems
  • CE marked to BS EN 14509: 2013.

General information

Material

Cor-Ten

Shape

Rectangle

Warranty description

-

Manufacturer guidance

Kingspan Facades will provide external coating and product guarantees on an individual project basis.

Uniclass

Pr_25_71_14_96 Weathering steel cassette panelsPrimary

CAWS

H92/120 Rainscreen cladding

Specification data - Weathering steel cassette panels

Classification data

Sheet

-

Thickness

2 mm.
3 mm.

Form

-

Height

-

Manufacturer guidance

Contact the Kingspan technical department for information on corten sizes and insert requirements.

Width

-

Manufacturer guidance

Contact the Kingspan technical department for information on corten sizes and insert requirements.

Fixing

Colour matched rivets within joint.

Reaction to fire

-

Panel external face

To EN 13501-1, A1.

Joint width

30 mm.

Sustainability data

Material

Cor-Ten