Verified by manufacturer 3 months ago
40 mm Core Thickness
EPD
Certificate type
Fire Safety Certification
Certificate type
DoP
Certificate type
FM Approved
Certificate type
Lower embodied carbon through-fix, trapezoidal profiled, insulated wall panels.
Horizontal and vertical applications.
Environmental:
Kingspan QuadCore:
Quality and Durability:
Kingspan insulated panels are manufactured from the highest quality materials, using state of the art production equipment to rigorous quality control standards, complying with:
Certification and Testing:
Reaction to Fire:
QuadCore KS1000RW LEC Wall Panels are classified B-s1,d0, when tested on the internal face of the product, according to the European Reaction to Fire classification system (Euroclasses) BS EN 13501-1:2018 under the certified name KS1000RW when using the following internal liner:
Please contact Kingspan Tech-eXchange for information relating to the external face.
Fire Resistance:
Fire resistance classifications are subject to panel thickness, orientation, method of assembly, and steel coating. Please contact Kingspan Tech-eXchange for project specific details.
Insurer Approvals:
QuadCore KS1000RW LEC Wall Panels are tested to:
Insurer approvals are large scale testing regimes that provide objective third-party testing, which is underpinned by quarterly, bi-annual and annual factory surveillance audits (depending on the region) to verify compliance.
Insurer approvals are subject to panel thickness, cover width, orientation, method of assembly, steel coating and manufacturing facility. Please contact Kingspan Tech-eXchange for further information.
Kingspan Tech-eXchange:
Kingspan Tech-eXchange is our dedicated team supporting you during the conception, design and installation of your project using our building envelope solutions, Kingspan Tech-eXchange supports our customers using the latest modelling and design software packages.
QuadCore® Assured System Warranty:
Please contact Kingspan Tech-eXchange or refer to the ‘QuadCore Assured’ brochure for a list of accessories covered by Kingspan.
Kingspan Planet Passionate:
Planet Passionate is Kingspan’s ambitious 10 year global sustainability programme which aims to impact three big global issues:
By setting ourselves challenging targets in the areas of energy, carbon, circularity and water, we aim to make significant advances in the sustainability of both our business operations and our products.
Material | Steel |
Shape | Rectangle |
Length | Bespoke |
Width | 1000 mm |
Height | 71 mm 84 mm 91 mm 104 mm 111 mm Manufacturer guidanceOverall thickness. |
Warranty description | 25 year Guidance for specification option: QuadCore Assured Panel Warranty:
QuadCore Assured System Warranty:
30 year Guidance for specification option: Up to 30 years coating performance. Manufacturer guidanceQuadCore® Assured Panel Warranty. |
Uniclass | |
CAWS | H43/120 Metal insulating sandwich panel H43/10 Metal insulating sandwich panel |
Standard | To BS EN 14509. |
Panels | Self-supporting double skin metal faced insulating panels. Factory made products. |
Panel construction | |
Panel external face | |
Material | Steel. |
Grade | S280GD. |
Profile | Trapezoidal. |
Panel internal face | |
Material | Steel. |
Grade | S220GD. |
Profile | Ribbed. |
Core insulation | QuadCore, 40 mm.Manufacturer guidanceQuadCore KS1000RW LEC Wall Panels are manufactured with an HCFC, CFC and HFC free QuadCore insulation core. |
Panel dimensions | |
Length | Manufacturer guidanceStandard Lengths: 1.8-14.5 m. Longer lengths (non-standard): 14.5-29.2 m. Shorter lengths (non-standard): Below 1.8 m. Note: Additional costs and transport restrictions may apply for non-standard lengths. All lengths may change for export (outside of the UK). |
Cover width | 1000 mm. |
Thickness | 71 mm. |
Joint type | |
Side or vertical | Overlapping.Guidance for specification option: Overlapping joint with butyl tape sealant. Other joint configurations are available. Please contact Kingspan Tech-eXchange for further information. |
End or horizontal | Overlapping.Guidance for specification option: Overlapping joint with co-laminate end lap seal. Other joint configurations are available. Please contact Kingspan Tech-eXchange for further information. |
Taper | Manufacturer guidancePlease contact Kingspan Tech-eXchange for further information. |
Finish as delivered | |
Outer skin | |
Material | PUR - Spectrum 50.Guidance for specification option: Kingspan Spectrum: Consists of a coated semigloss finish with slight granular effect. |
Thickness | 50 μm (Spectrum 50).Guidance for specification option: Kingspan Spectrum. |
Colour | Goosewing Grey RAL 080-70-05.Merlin Grey RAL 180-40-05.Onyx RAL 7016.Pure Grey RAL 000-55-00.Grey White RAL 9002. |
Inner skin | |
Material | SP.Guidance for specification option: CLEANsafe 15: The coating has been developed for use as the internal lining of insulated panels. Standard colour is “bright white” with an easily cleaned surface. |
Thickness | 15 μm.Guidance for specification option: CLEANsafe 15. |
Colour | Bright white. |
Integral accessories | Self-drilling, self-tapping stainless steel primary fasteners with non-ferrous EPDM backed washer.Stainless steel secondary fasteners with non-ferrous EPDM backed washer.Butyl tape sealants.Film backed butyl tape.PVC foam tape.Butyl co-laminate tape sealant.Non-setting butyl sealant.Manufacturer guidancePlease contact Kingspan Tech-eXchange for further information. |
Special features | Manufacturer guidancePlease contact Kingspan Tech-eXchange for further information. |
Fire performance | |
Reaction to fire | |
Core | Manufacturer guidancePlease contact Kingspan Tech-eXchange for further information. |
Panel external face | Manufacturer guidancePlease contact Kingspan Tech-eXchange for further information. |
Panel internal face | To BS EN 13501–1, Class B-s1, d0.Guidance for specification option: Please contact Kingspan Tech-eXchange for further information. |
Fire resistance | Manufacturer guidanceFire resistance classifications are subject to panel thickness, orientation, method of assembly, and steel coating. Please contact Kingspan Tech-eXchange for project specific details. |
U-value | 0.47 W/m²·K. Manufacturer guidanceQuadCore KS1000RW LEC Wall Panels have a Thermal Transmittance (U-Value), calculated using the method required by the Building Regulations Part L2 (England & Wales), Building Standards Section 6 (Scotland), Part L (Republic of Ireland) and Part F2 (Northern Ireland). |
Weight | 9.0 kg/m². |
Global warming potential (GWP) | 23.12 kg CO₂ eq/m². |
Third-party certification | EPD Hub Environmental Product Declaration. Guidance for specification option: In accordance with EN 15804+A2 and ISO 14025/ ISO 21930. |
Material | Steel |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | 34.97 kg CO₂ eq/m² Guidance for specification option: Rounded to nearest decimal point. 34.969 kg CO₂ eq/m². Maximum (based on thickest panel). |
EPD
Environmental Product Declaration Kingspan QuadCore KS1000 RW LEC
EPD
Environmental Product Declaration Kingspan QuadCore KS1000RW LEC Wall Panel
Fire Safety Certification
FIRE REACTION CLASSIFICATION IN ACCORDANCE WITH EN 13501-1:2018
DoP
QuadCore KS1000RW Roof and Wall Declaration of Performance
FM Approved
FM Report PR464489