Verified by manufacturer 7 months ago
Fire-resistant, laminated safety glass.
Multiple applications where fire-resistant glazing is required including glazed partitions and doors with double-glazing options available for curtain walls and windows.
Suitable for applications with in service temperatures between -10°C and +50°C.
Fire-resistant, laminated safety glass which enhances the safety of individuals present from risks.
Features and benefits:
Please note, fire-resistant glazing must always be installed in a framing system where there is independent certification for the glazing and its intended framing system. Please consult manufacturer for technical support.
Color | Clear |
Material | Glass |
Shape | Rectangle |
Length | Bespoke |
Width | Bespoke |
Height | Bespoke |
Warranty description | Five year |
Uniclass | |
CAWS | L10/33 Proprietary windows L10/25 Aluminium windows L10/20 Steel windows L10/15 Wood windows L10/10 Wood windows L10/400 Composite windows L10/390 Proprietary windows L10/330 Aluminium windows L10/310 Steel windows L10/210 Wood windows |
General requirements | Glass generally. |
Third-party certification | Certifire CF 5746. |
Laminate glass type | Fire-resistant glass. |
Thickness | 16–34 mm.Guidance for specification option: Range for single glazing. Dependant on the project requirements. |
Outer leaf | Manufacturer's standard. |
Mid leaf | Manufacturer's standard. |
Interlayer to glass leaves | Manufacturer's standard. |
Body colour | Clear.Guidance for specification option: Standard. Extra-clear (Clearvision). |
Pattern | Transparent. |
Performance requirements | |
Fire resistance | |
Integrity | To BS EN 13501-2, E 15–120 minutes. |
Insulation | To BS EN 13501-2, I 15–60 minutes. |
Radiation | To BS EN 13501-2, W 20–120 minutes. |
Light | Transmission: 87%.Guidance for specification option: Consult manufacturer. |
Sound attenuation | 37 dB.Guidance for specification option: Rw. Special order.Guidance for specification option: Other solutions can be offered upon request. |
Impact resistance | To BS EN 12600, 1B1.Guidance for specification option: In accordance with EN 12600. |
Overall size | 2000 x 4500 mm. Guidance for specification option: Maximum dimensions approved in the applicable fire test report. Consult manufacturer. |
Contains Red List materials | No |
Country of material origin | Europe Manufacturer guidanceMaterials originate from around Europe. |
Country of product manufacture | Europe |
Recyclability | 100% |