OS2 PSU
Compare variants

OS2 PSU

SE Controls Variant:

A range of powerful 24 V d.c. control systems designed to drive two-wire 24 V d.c. actuators in a smoke control and/ or environmental ventilation system.

Jump to:
+44 (0)1543 443060 www.secontrols.com

Application

Environmental and smoke ventilation

Description

A range of powerful 24 V d.c. control systems designed to drive two-wire 24 V d.c. actuators in a smoke control and/ or environmental ventilation system.


Features and benefits:

  • Provides a flexible solution, offering various configurations of output power and control-zone inputs.
  • Operating from a 230 V a.c. supply, the panels can deliver various current outputs to drive 24 V motorized actuators and magnetic catches.
  • Can be mounted in a centralized location. Each panel can operate independently or can be linked to others to produce a networked control system. The networked control system, in turn, can operate standalone or be linked to a building management system (BMS).
  • Certified and tested in accordance with EN 12101-10.
  • Internal temperature sensor installed to provide optimal battery charging compensation as the ambient temperature changes.
  • Made in Britain.
  • CE marked.
  • Also available in a 30 A model (specified separately; see 'OS2 SHEVTEC Control Panel), 150 A and multi-zone versions.


Technical characteristics:

  • Humidity range: 10–90%, non-condensing.
  • Storage: -20 to +50°C.
  • Operating temperature for control panel (not including batteries): -5 to 40°C.

General information

Color

White

Shape

Square

Size

600 x 600 x 250 mm

Uniclass 2015

Pr_75_50_18_51 Mechanical services control panelsPrimary

CAWS

S92/410 Control panels

Specification data - Mechanical services control panels Enhanced data

Enclosure

-

Ingress protection (minimum)

IP30.

Material

Steel.

Colour

White.

Doors and panels

-

Form

Right-angle return construction with rounded edges and corners, concealed hinges and internal gaskets.

Swing

Manufacturer's standard.

Hardware

Manufacturer's standard.

Locks

Manufacturer's standard.

Isolator

-

Rated operational current (In)

30 A.

Rated operational voltage (Ue)

230 V.

Rated operational frequency

50/60 Hz.

Number of poles

Manufacturer's standard.

Output nominal 24 V d.c. multi-channels, output not to exceed 8 A per channel.

Cable entry

Via 32 x 20 mm top-mounted cable glands.

Execution

Dedicated compliant power supply required.

Product Reference

1 Zone 60A PSU Panel (FCS12001060)

Battery back-up

2 x 12 V d.c. 22.0Ah sealed lead-acid batteries (per 30 A output).

  • Standby time: 72 hours with maximum 100 mA standby drain on PER permanent (Standby drain current comprises of enabled fire inputs, communication cards, and other loads connected to PER).
  • Expected battery life: 3+ years at 25°C.
  • Real time clock battery life: Ten years.

Literature

Understanding Smoke Ventilation Compliance

Understanding Smoke Ventilation Compliance

SE Controls Product Specification Guide

SE Controls Product Specification Guide

Similar products from SE Controls

Fan Control Panel

Fan Control Panel

NV LogiQ PSU

NV LogiQ PSU

OS Loop Coordinator

OS Loop Coordinator

OS2 SHEVTEC Control Panel

OS2 SHEVTEC Control Panel

SHEVTEC® Repeater Panel

SHEVTEC® Repeater Panel