A single door control unit in 12 V, 2 A PSU Plastic Cabinet. Connects to the IP infrastructure using an RJ45 plug into a standard TCP/IP Ethernet network and makes access control decisions.

Jump to:
BOS
+44 (0)1273 811011 Website

Application

There is a label on the Net2 plus control unit that clearly shows colour coded connections for reader, power supply etc. The unit has a voltage free relay and so can switch any lock or electrical device. Exit buttons, door contacts, tamper switches and alarm devices may be connected.


Control units communicate to the PC via the standard TCP/IP protocol of a LAN. The Net2 plus control unit should be given a fixed/static IP address. All configuration of the unit is done using the Net2 Configuration Utility.


There are diagnostic LEDs mounted close to their relevant terminals to assist with trouble free installation. End of line resistors can be switched into the circuit as required. External terminating resistors are not required.

 

Operation – Any changes made at the PC are immediately communicated and stored at the control unit. When a user presents their token to the reader, the control unit identifies them and permits or denies access as appropriate.

Description

Net2 Plus is a single door access control unit. It has on-board TCP/IP to allow direct connection to a computer network, this can save time, money and result in a better, more resilient system.


Features and benefits:

  • Can also be connected together using a dedicated RS485 network. This reduces the number of TCP/IP network points required for larger systems.
  • Hardware features include the following: Volt free control relay x 2, Input for PSU fail, Input for tamper, Alarm output, Dedicated intruder alarm input.
  • The 12 V, 2 A Power supply unit is available in either a plastic or metal cabinet.
  • The cabinet can house both the 12 V, 2 A PSU and a Net2 and the option to accommodate a 12 V /7 Ah back-up battery if desired.
  • A tamper switch is also installed which registers an alarm if the lid is opened when connected to an ACU.
  • Single door networkable access control unit.
  • Plug into a TCP/IP network using a RJ45 plug.
  • Features a built in TCP/IP converter.
  • Different control units can be mixed on a site.
  • FLASH memory allows easy upgrades.
  • Use Paxton or third-party readers.


The Net2 plus control unit connects to the central administration PC using an RJ45 plug into a standard TCP/IP Ethernet network. This greatly increases the flexibility of installation options on sites that have LAN/WAN networks. The Net2 plus control unit also has a RS485 connection. This means it can be connected to other Net2 plus control units using a dedicated CAT5 cable.


One Net2 plus control unit can be the network interface to the LAN and also run a wired RS485 daisy chain of other Net2 plus units, removing the need for an independent TCP/IP to RS485 converter. Net2 plus is also available with a Power over Ethernet (PoE) power supply. PoE is a technology that allows both power and data to be passed along Ethernet cabling. Net2 plus with PoE simply plugs straight into the existing LAN using a standard RJ45 plug (providing it is powered by either a compatible PoE switch or a PoE injector).


  • Net2 Plus is supplied as a PCB only or in a cabinet with or without a power supply. Both metal and plastic cabinets are available, with a 2 A or PoE+ power supply. Both metal and plastic cabinets are available, with a 2 A (battery backup recommended) or PoE+ (UPS recommended) power supply.

General information

Color

White

Material

Plastic

Shape

Rectangle

Length

320 mm

Width

236 mm

Height

80 mm

Warranty description

Five year

Uniclass

Ss_75_40_02_11 Card access control systemsPrimary

CAWS

W90/363 Access control units

W90/130 Electronic access control system

Product range

Net2 Door Controllers
Net2

Specification data - Card access control systems

System supplier

Paxton Access Limited.

System type

Online access control system.

Equipment interconnectivity

Wired.

Control software

Net2 software.

Readers

Net2 range of readers.

Guidance for specification option:

Or tested third party readers. Contact manufacturer for details.

Locking mechanisms

-

Manufacturer guidance

Any lock rated to the max output of Relay 1 or Relay 2. Contact manufacturer and insert requirements.

Door status monitoring

Net2 Plus, I/O board.

Cable type

Two-way plug UL.

System accessories

2 A/ 12 V d.c. power supply - Plastic cabinet.

Guidance for specification option:

857-250.

Net2 I/O board - 12 V 2 A PSU, Plastic cabinet.

Guidance for specification option:

411-623.

Net2 Plus 1 door controller - 12 V 2 A PSU, Plastic cabinet.

Guidance for specification option:

682-531.

Net2 nano 1 door controller - 12 V 2 A PSU, Plastic cabinet.

Guidance for specification option:

654-772.

Current

12 V d.c.

Frequency

50–60 Hz.

NominalSupplyVoltage

100–240 V a.c.

Operating temperature

0–45°C.

Sustainability data

Country of product manufacture

United Kingdom

Material

Plastic

BIM objects

BOS

NBS BIM Object Standard

This BIM object has been authored to meet the requirements of the NBS BIM Object Standard.

Find out more about the NBS BIM Object Standard.

Platform Compatible Version
IFC
-

1

Revit
-

1

Third party certifications

UL Listed

UL Listed

UL 293, OUTLINE OF INVESTIGATION FOR PERFORMANCE OF ACCESS CONTROL SYSTEM UNITS INTENDED FOR USE IN THE UK

UL Listed

UL293 - UK Standard for Access Control System units intended for use in the UK

UL Listed

UL Listed

UL 294, Access Control System Units; CSA 22.2 No. 205-1983, Signal Equipment

UL Listed

UL Listed

UL 294 - Access Control System Units CSA 22.2 No. 205-83 - Signal Equipment

UL Listed

UL Listed

UL 294 - Access Control System Units CSA 22.2No. 205-83 - Signal Equipment

UL Listed

UL Listed

UL 294 - Access Control System Units CSA 22.2 No. 205-83 - Signal Equipment - PaxLock Pro, External

UL Listed

UL Listed

UL 294 - Access Control System Units CSA C22.2 No. 205 - Signal Equipment

UL Listed

UL Listed

UL 294 - Access Control System Units CSA C22.2 No. 205 - Signal Equipment - Net2 ACU and readers

UL Listed

UL Listed

UL 60950-1 & CAN/CSA C22.2 No. 60950-1-07 - Information Technology Equipment - Safety - Part 1: General Requirements

UL Listed

UL Listed

UL 60950-1 & CAN/CSA C22.2 No. 60950-1-07 Information Technology Equipment - Safety - Part 1: General Requirements

UL Listed

UL Listed

UL 60950-1, CAN/CSA C22.2 No. 60950-1-07, Information Technology Equipment - Safety - Part 1: General Requirements

UL Listed

UL Listed

UL 60950-1 & CAN/CSA C22.2 No. 60950-1-07 - Information Technology Equipment - Safety - Part 1: General Requirements - Entry Panel

UL Listed

UL Listed

UL 60950-1 : Information Technology Equipment - Safety - Part 1: General Requirements CAN/CSA C22.2 No. 60950-1-07 : Information Technology Equipment - Safety - Part 1: General Requirements

Literature

Net2 Plus 12v 2A PSU, Plastic Cabinet - data sheet

Net2 Plus 12v 2A PSU, Plastic Cabinet - data sheet

Net2 Plus 12V 2A PSU, Plastic Cabinet - instructions

Net2 Plus 12V 2A PSU, Plastic Cabinet - instructions

12v 2A PSU, Plastic Cabinet - data sheet

12v 2A PSU, Plastic Cabinet - data sheet

Net2 complete system - schematic

Net2 complete system - schematic

System Guide

System Guide

Product Catalogue

Product Catalogue

Similar products from Paxton Access Ltd

Entry - Audio Monitor - Intercom Handset

Entry - Audio Monitor - Intercom Handset

Entry - Premium Monitor - Intercom Handset

Entry - Premium Monitor - Intercom Handset

Entry - Standard Monitor - Intercom Handset

Entry - Standard Monitor - Intercom Handset

Entry - Standard Panel - Intercom Call Station

Entry - Standard Panel - Intercom Call Station

Entry - Touch Panel - Intercom Call Station

Entry - Touch Panel - Intercom Call Station

Entry - VR Panel - Intercom Call Station

Entry - VR Panel - Intercom Call Station

Entry monitor  - Desktop Stand

Entry monitor - Desktop Stand

Net2 Air Bridge

Net2 Air Bridge

Net2 Desktop Reader, USB - Enrolment Reader

Net2 Desktop Reader, USB - Enrolment Reader

Net2 I/O Board 12V 2A PSU, Plastic Cabinet - I/O Module

Net2 I/O Board 12V 2A PSU, Plastic Cabinet - I/O Module