Verified by manufacturer 1 month ago
BBA Agrément Certificate
Certificate type
NSAI Agrément Certificate
Certificate type
APP modified bitumen polymer waterproofing membrane.
TOP/S is an APP modified bitumen polymer waterproofing membrane. The pre-fabricated membranes of the TOP series are obtained by coextrusion of an elastoplastomeric bitumen-polymer blend. TOP/S contains a non-woven polyester reinforcement with continuous filament and dimensional stability controlled with longitudinally positioned mineral fibres.
The upper side is finished with a sanded surface and the lower side of the membrane is covered by the TERMOTENE thermal cut-off film, which improves application and adhesion to the substrate being waterproofed.
Features and benefits:
Color | Black |
Finish | Sanded |
Material | Polymer Bitumen Polypropylene |
Shape | Other |
Length | 10000 mm |
Width | 1000 mm |
Height | 3 mm |
Warranty description | Manufacturer guidanceFor the duration of the MOY Warranty. |
Uniclass | |
CAWS | J31/353 Waterproof coating J41/110 Built-up reinforced bitumen membrane warm deck roof covering J41/400 Built-up reinforced bitumen waterproof covering J41/10 Reinforced bitumen membrane warm deck roof covering J31/47 Waterproof coating |
Standard | To BS EN 13707. |
Performance characteristics | External fire performance to CEN/TS 1187:2012, Class BROOF (t4).Guidance for specification option: Consult manufacturer for details. |
Material | |
Carrier material | Atactic polypropylene (APP). |
Bitumen modification | Polymeric. |
Thickness (minimum) | 3 mm.Guidance for specification option: (±5%). Manufacturer guidanceTo EN 1849-1. |
Weight (minimum) | Manufacturer guidanceConsult manufacturer for details. |
Surface finish | |
Top | Sanded. |
Underside | Termotene® thermal cut-off film. |
Third-party certification | British Board of Agrément (BBA) and National Standards Authority of Ireland (NSAI) certified. |
Roll size | To EN 1848-1, ≥10000 x 1000 mm (-1%). |
Watertightness | To EN 1928-B, ≥60 kPa. |
Cold flex temperature | To EN 1109, ≤-10°C. Manufacturer guidanceCold flexibility. |
FlowResistanceRange | To EN 1110, ≥120°C. Manufacturer guidanceFlow resistance at elevated temperature. |
Elongation (to EN 12311‐1) | 40% (longitudinal); 45% (transverse). Guidance for specification option: (±15). |
Tensile strength (to BS EN 12311-1) | 700 N/5 cm (longitudinal); 450 N/5 cm (transverse). Guidance for specification option: (±20%). |
Dimensional stability | To EN 1107-1, 0.25%. |
Tear resistance (BS EN12310-1) | 150 N (longitudinal); 160 N (transverse). Guidance for specification option: (±30%). |
Fire reaction (EN 13501-1) | Euroclass F. |
Contains Red List materials | No |
Country of material origin | Italy |
Country of product manufacture | Italy |
Material | Polymer Bitumen Polypropylene |
Embodied carbonA1-A3 (production stage) as defined in BS EN 15804 | Manufacturer guidanceBiogenic Carbon Content: In Product: 0 kg C/m2 In Packaging: 0.04 - 0.05 kg C/m2 |
Recyclability | Due to the thermoplastic properties of their principle components (bitumen, polyester reinforcements, polymers, fusible plastic film), bitumen waterproofing sheets can be converted into mass bitumen products like road asphalt – significantly reducing the demand for virgin bitumen. |
Recycled contentAs defined in clause 7.8 of BS EN ISO 14021 | 3 % |
MOY Elotene DSN - Self-adhesive Bituminous AVCL/Carrier
MOY Parabase 3 kg - Modified Bitumen AVCL
MOY Paraflex ARD/HS Cap Sheet - Waterproofing Membrane
MOY Paraflex ARD/S Cap Sheet - Modified Bitumen Waterproofing Membrane
MOY Paraflex NT3 Base Layer - Modified Bitumen Waterproofing
MOY Paralon Antiroot (NT4) Cap Sheet - Waterproofing Membrane
MOY Paralon ARD/HS Cap Sheet - Modified Bitumen Waterproofing Membrane
MOY Paralon ARD/S Cap Sheet - Waterproofing Membrane
MOY Paro-Melt® Hot Melt Protection Membrane - Reinforced Waterproofing Membrane
MOY Sticker ARD Cap Sheet - Self-adhesive Modified Bitumen Cap Sheet