Twin Frame system is typically used to divide habitable dwellings.
Plasterboard partition system.
Twin Frame system is typically used to divide habitable dwellings. The twin stud build up, combined with Knauf’s high performance plasterboards, maximizes acoustic performance in order to comply with building regulations, technical handbooks and guidance for sound insulation.
Testing Methodology: BS EN 1363-1 AND BS 476-20
Knauf interior drywall partition systems* that achieve a fire resistance performance are tested in accordance with BS EN 1363-1 and BS EN 1364-1. These are the up to date and most rigorous test methodology standards to follow.
Determining the maximum height of a drywall partition as per the BS EN 1363-1 fire test methodology, is typically restricted by the 3 metre height of the test furnace.
To understand the true maximum height of the system whilst under fire test conditions (‘Fire State Height’), there are three options. Increases can be determined by utilising greater test furnace heights, via Extended Field of Application (as outlined in BS EN 15254-3 - it is important to note this standard applies to single metal frame symmetrical systems only), or via BS EN 1364-1.
The BS 476-20 standard is also restricted by the 3 metre height of the test furnace. However, under this BS standard, increasing the maximum heights of a system can be based on the ‘Cold State Height’. The cold state height is calculated using structural engineering methods to L/240 @ 200Pascals. (L = Height of wall). Regulatory Requirements
Specific to Approved Document B (England) there is a requirement to use European classifications and fire resistance test methodologies in accordance with BS EN 1363-1 and BS EN 1364-1, which means that the fire state height must be considered. However, Approved Document B (England) currently allows the usage of the BS 476 series, though it should be noted that, following consultation, the full BS 476 series will be removed in 2029. For other nationals, please consult relevant approved documents, technical guidance, and handbooks.
Knauf Approach & Recommendations:
Knauf advise and promote that EN compliance should be followed. That is to say Knauf advise utilising an BS EN 1364-1 fire resistance test and extend the maximum height of a drywall partition system via either BS EN 15254-3, BS EN 1364-1 or via a fire resistance test within a test rig greater than 3m in height.
Projects that wish to use the BS 476 series must gain agreement between the Client, Accountable Persons, Duty Holders, and Local Building Control that the cold state height is an acceptable methodology. For further information on Knauf system types that are applicable to support projects focusing on BS compliance, refer to Knauf Systems Performance Tables (BS compliance).
Material | Gypsum Metal Glass mineral wool |
Shape | Rectangle Other Square |
Width | Bespoke |
Height | Bespoke |
Warranty description | Lifetime Guidance for specification option: Knauf Specification Disclaimer - Supply of Knauf products and systems for your project is typically made via distribution in accordance with Knauf’s ‘standard terms and conditions of sale. Please be advised that Knauf’s design liability is strictly limited to the manufacture of its tested products and systems, in their tested arrangements, in accordance with the enclosed specification document, specification clauses and standard details. Knauf does not warrant nor accept any liability for the design, overall health and safety or functionality of any interfaces within the building between its stand-alone products and/or systems and any other sections or interfaces. Download the full Specification Disclaimer here: Knauf Specification Disclaimer | Knauf UK | NBS Source View Knauf's Standard Terms and Conditions of Sale here: Manufacturer guidanceThe 100% Knauf System Performance Warranty - Knauf warrants that its Systems will perform to the specified requirements throughout the lifetime of the building, when installed properly and under normal conditions. The 100% Knauf System Performance Warranty guarantees that your Knauf systems are:
Download the full System Performance Warranty here: The 100% Knauf System Performance Warranty | Knauf UK | NBS Source |
Knauf Core Board Data Sheet
Knauf Performance Plus Data Sheet
Knauf Systems Performance Tables (EN Compliance)
Knauf Systems Performance Tables (BS Compliance)
The 100% Knauf System Performance Warranty
Knauf Performance Plus Screws Data Sheet
Knauf Soundshield Plus Data Sheet
Knauf DF U Channel Data Sheet
Knauf U Channel Data Sheet
Knauf Flat Fixing Plate Data Sheet
Knauf Fill and Finish Light Data Sheet
Knauf Paper Joint Tape Data Sheet
Knauf Insulation Acoustic Roll Data Sheet
Knauf Fire Rated Deflection Heads Document